eHouse Mfumo - Smart nyumbani , Akili House , Jengo , Gorofa .





Kusimamia na kudhibiti:
Nyumbani Automation usimamizi kutoka: eHouse mfumo wa nyaraka . Tafadhali rejea kwa nyaraka newest zinazopatikana eHouse mfumo wa nyaraka na Kipolishi Kiingereza
eHouse mfumo blog katika Kipolishi Mfumo wa utekelezaji , kubuni mifano nk .
eHouse mfumo blog katika lugha zingine Mfumo wa utekelezaji , kubuni mifano nk .
eHouse mfumo - smart nyumba , nyumbani automatisering , kujenga mfumo wa usimamizi rasmi ukurasa

Meza yaliyomo

1 . Kuanzishwa . 4

1 . Urahisi , faraja , automatisering . 4

1 . 2 . Usalama . 4

1 . 3 . Uchumi , nishati ya akiba . 5

2 . eHouse mfumo versions . 5

2 . 1 eHouse 1 chini PC usimamizi . 7

2 . 1 . Takwimu na nguvu mabasi ya eHouse 1 System . 9

2 . eHouse 1 chini ya usimamizi wa CommManager . 10

2 . 3 . Ethernet eHouse (eHouse 2) 11

3 . eHouse System Controllers . 11

3 . 1 RoomManager (RM) . 11

3 . 1 . Signaler Maelezo . 12

3 . 1 . Analog Pembejeo (ADC) . 12

3 . 1 . 2 . Digital Pembejeo . 13

3 . 1 . 3 . Digital Matokeo 14

3 . 1 . 5 . PWM (Pulse Upana Modulated) Matokeo . 15

3 . 1 . 6 . IR Remote Udhibiti wa RoomManager . 17

3 . 1 . 7 . Kudhibiti na ndogo - miniatyr IR / RF kijijini mtawala (elektroniki ufunguo) 22

3 . 1 . 2 . Ugani modules kwa RoomManager . 22

3 . 1 . 2 . 1 Bluetooth Moduli . 22

3 . 1 . 2 . Mifare Kadi ya kupata Reader . 22

3 . 2 ExternalManager - Roller Mdhibiti 23

3 . 2 . 1 . Signaler maelezo . 24

3 . 2 . 1 . Rollers , milango , milango anatoa matokeo . 24

3 . 2 . 1 . 2 . PWM (Pulse Upana Modulated) Matokeo . 25

3 . 2 . 1 . 3 . Digital Matokeo . 26

3 . 2 . 1 . 4 . Digital Pembejeo . 26

3 . 2 . 1 . 5 . Analog pembejeo . 26

3 . 2 . Moja kwa moja mitaa kudhibiti na RF elektroniki muhimu . 27

3 . HeatManager - Boiler Room na Kati joto mtawala 28

3 . 1 . HeatManager Matokeo . 29

3 . 2 . HeatManager Matukio . 31

3 . 4 . InputExtender I / II (Security System) 39

3 . 5 . Expander (EX) . 45

3 . 5 . 1 . Expander matokeo na connectors kwa IE / IE2 45

4 . eHouse PC Package eHouse (1 Programme) 63

4 . 1 . eHouse Maombi 63

4 . 1 . eHouse maombi ya vitengo . 64

4 . 1 . RoomManager Configuration . 64

4 . 1 . 2 . Analog Pembejeo Vipimo 65

4 . 1 . 3 . Digital Pato Configuration 66

4 . 1 . 4 . Infrared Mazingira (Remote Control) . 66

4 . 1 . 5 . Elektroniki RF Vipimo muhimu (kwa ExternalManager) . 67

4 . 1 . 6 . InputExtender Mazingira . 67

4 . 1 . 7 . Kipanya Usimamizi . 68

4 . 1 . 8 . Ruhusa na upatikanaji wa kudhibiti . 68

4 . 1 . 9 . Ziada utendaji wa maombi eHouse . 69

4 . 2 . Bluetooth Gateway (BlueGate.exe) 71

4 . 3 . eMail Gateway (EmailGate.exe) . 71

4 . SMS Gateway (SmsGate.exe) . 72

4 . 5 . WDT kwa eHouse (KillEhouse.exe) 76

4 . 6 . Akustisk meddelanden (Player.exe) . 76

4 . 7 . FTP Gateway (FtpGate.exe) . 76

4 . 8 . Internet kudhibiti browser vipengele . 77

4 . 8 . 1 . Nakala HTML Kudhibiti . 79

4 . 8 . 2 . Graphic Kudhibiti HTML + Maps . 80

4 . 8 . 3 . Graphic kudhibiti XML + faili . 80

4 . 8 . 4 . Graphic Kudhibiti faili + JavaScript (compression) . 80

4 . 8 . 5 . Moja kwa moja FTP kudhibiti (Windows Explorer au FTP mteja) . 80

4 . 9 . Mkono Remote Meneja eHouse . 82

4 . 10 . eHouseMobile (Windows Simu 6 . 0 na waandamizi) 88

4 . 11 . Maoni na vitu viumbe kwa ajili ya kudhibiti visualization na graphical . 88

4 . 11 . 1 . Moja kwa moja kuchora kwa msaada wa Jumla Kazi . 88

4 . 11 . 2 . Mwongozo kuchora ya vitu . 89

4 . 12 . Akustisk notification viumbe . 90

1 . Kuanzishwa .

" Akili nyumba " mrefu maana kila aina ya mifumo automatisering nyumbani kwa kudhibiti , kuendesha gari ya mifumo huru na mitambo kuingizwa katika jengo . Nyumbani automatisering mifumo ya kukabiliana na wengi tofauti kujenga aina; nyumba , gorofa , ofisi , hoteli , nk .

Nyumbani automatisering mifumo ya sasa ni muhimu zaidi mfumo trimming na vifaa ya nyumba .

Pamoja na zaidi na zaidi kwa bei ya nishati ghali , ikolojia ya vikwazo kwa mpya ya majengo , kurekebisha mfumo wa uwekezaji matarajio haya ni kivitendo inestimable .

Flexibilitet wa baadhi ya automatisering nyumbani mifumo ya kuruhusu reconfigure ni pamoja na mabadiliko ya matarajio wakati wa matumizi ya jengo , bila umuhimu wa kubadilisha mitambo ya umeme wa jadi pamoja pamoja na ukarabati wa nyumba kuporomoka .

Nyumbani automatisering mifumo ya kuruhusu kuongeza faraja ya maisha , usalama , uchumi , kuokoa nishati , kupunguza bei ya kuishi katika nyumba au gorofa .

1 . Urahisi , faraja , automatisering .

eHouse mfumo wa matumizi ya kumuwezesha tata , ndani na kijijini kudhibiti wa mwanga , joto , umeme na elektroniki vifaa ndani ya nyumba , gorofa , ofisi , hoteli , nk . Inajenga uwezekano wa kudhibiti Audio - Video , HiFi mifumo na emulating signaler infrared mtawala kijijini ambayo inaweza kujifunza na kunyongwa na mfumo eHouse . Kuna uwezekano wa kusimamia advanced sana Boiler chumba ufungaji: inapokanzwa , baridi , recuperation , uingizaji hewa , nishati ya jua , Boiler , joto buffer , bonfire kwa maji moto hewa Jacket na mfumo wa usambazaji .

eHouse inawezesha mfumo wa kudhibiti na swichi ya kawaida , IR kijijini mtawala , GSM simu , PC , paneler kugusa graphic kazi msingi Windows XP , Madirisha Simu 6 na waandamizi wao , internet browser , madirisha Explorer , ftp mteja maombi .

eHouse mfumo graphics jopo udhibiti ni barabara ya kiwango PDA au PC na hutolewa programu . Visualization picha zinaweza umba mmoja mmoja kwa ajili ya ufungaji yoyote mwisho user .

eHouse Controllers wajumbe kubwa , advanced kipanya ambayo inaweza iliyowekwa ya kuendesha huduma , mara kwa mara , kuahirishwa na kazi msimu moja kwa moja . PC msaada itawezesha kujenga programu mwenyewe ambayo kazi pamoja na mfuko eHouse , kufanya kumbukumbu na kukimbia watumiaji advanced algorithms ambayo inaweza kuwa muhimu au kuonekana katika siku zijazo .

1 . 2 . Usalama .

Nyumba ni zaidi basi gorofa hatarini , kutokana na umbali kubwa ya majirani na pia pointi zaidi ya wiki . Ni wasiwasi uwezekano ya wizi , shambulio , wizi , moto , mafuriko , hujuma . Katika kesi ya wiki moja au kukosekana kwa mfumo madhubuti wa usalama na sensorer alarm ufuatiliaji wowote inawezekana matukio katika nyumba na premisses , kuhesabu jirani dazeni mita chache kutoka kwetu au mmenyuko polisi ni badala pia matumaini .

Matumizi mfumo wa eHouse ongezeko usalama wa nyumba na ujenzi wa , kwa sababu inashirikisha kujenga - katika mfumo wa usalama na GSM notification / SMS ya matukio . Inawezesha kuunganisha aina yoyote ya sensorer alarm (harakati , mvua , baridi , joto , moto , upepo , gesi , switches kwa uthibitisho wa kufunga milango , madirisha , rollers , milango , nk . ) . Mfumo wa usalama ni aktiverat nje ya eneo la kuulinda ambayo si kutoa muda zaidi kwa ajili ya hatua Intruders . eHouse anatoa nafasi ya kufanya kazi moja kwa moja kwenye Activation sensor , programed katika mfumo .

eHouse samlar moja kwa moja mbalimbali - Channel kuendesha rollers , milango , milango , kivuli awnings nk .

eHouse inawezesha mfumo kuiga mbele ya binadamu katika nyumba kwa mbio kufanyika matukio , kubadilisha TV , ambayo inaweza kukatisha tamaa Intruders kuangalia nyumba za kuvunja - katika .


1 . 3 . Uchumi , nishati ya akiba .

eHouse Mfumo wa kuhusisha mtawala juu ya kusimamia joto , cool , uingizaji hewa , recuperation , Boiler chumba , mfumo ya jua , joto buffer , bonfire na maji Jacket na usambazaji moto hewa , ambayo anaokoa nguvu nyingi na buffering na kutumia bure (nishati ya jua) au nishati rahisi vyanzo (kuni , imara nishati) . Inaweza kuwa programmerad ya kuendesha kikamilifu moja kwa moja bila kuingiliwa binadamu . Inawezesha uwezekano kikomo gharama ya inapokanzwa , baridi , uingizaji hewa mara chache kulingana na bei ya nishati kutumika .

Binafsi udhibiti wa joto vyumba na kudumisha yao kujitegemea , inazalisha akiba ya ziada ya percents kuhusu kadhaa kadhaa , na ufanisi matumizi ya nishati . Katika kesi hii yote joto katika vyumba kudhibitiwa kinachozingatiwa moja kwa moja kwenye ngazi iliyowekwa , bila overheating baadhi ya vyumba vya kuweka ombi joto katika nyingine mmoja . Hali ya hewa , jua , upepo , matukio ya hali ya hewa , muda na msimu , usanifu wa masuala ya , dirisha kawaida na maeneo hawana hayo makubwa ushawishi , kama ni juu ya mifumo ya kati inapokanzwa . Hakuna kubwa gradient kati ya vyumba ambayo mabadiliko kutokana na hali ya hewa , inapokanzwa nishati ya jua , upepo mwelekeo , na wengine wengi haitabiriki masuala .

Ziada akiba inaweza kupatikana kwa mwanga moja kwa moja byte mbali kwa kuweka yao kugeuka mbali moja kwa moja baada ya muda fulani au upande wao juu ya , kwa kipindi cha muda kama matokeo ya kutambua harakati .

Hii uwezekano wa mfumo eHouse inatoa fursa ya refund gharama ya ufungaji wakati wa 1 - 3 miaka (kulingana na gharama ya nishati kutumika) .

2 . eHouse mfumo versions .

eHouse Mfumo ni advanced ufumbuzi wa nyumbani automatisering ambayo kuwawezesha kudhibiti na ushirikiano wa vifaa wengi wa aina tofauti . eHouse inawezesha kufuatilia na kudhibiti hali ya joto , mwanga ngazi , inapokanzwa , baridi , humidity .

eHouse Mfumo inaweza kuwa imewekwa katika maeneo ya tambarare , nyumba , majengo ya umma , ofisi , hoteli na inaweza kutumika kama mfumo wa upatikanaji kudhibiti .

eHouse mfumo wa ufungaji inaweza kuwa ya kiuchumi , starehe au maximal .

Wengi Configuration variants ya mfumo eHouse inajenga uwezekano wa madaraka , kati , kusimamiwa na PC au huru ufungaji .

eHouse ni mfumo sanifu ambayo inatoa nafasi ya kujiuzulu si kutumika sehemu na maombi trim moja kwa moja na mwisho mahitaji user (e . g . HeatManager inaweza kuwa imeshuka katika ufungaji gorofa) .

eHouse ufungaji inaweza iliyoundwa na serikali kuu na moja kwa kila mtawala ngazi (LevelManager) au madaraka na controllers wengi wakatandaza juu ya vyumba . Katika kesi ya pili kuna kiasi kidogo 230V CABLING na urefu wa jumla yao ni mara chache mfupi na hufanya ufungaji bei nafuu sana , ambayo inazidi kufanya kwa ajili ya gharama kubwa ya controllers .

eHouse Inawezesha mfumo wa kudhibiti kivitendo kila kifaa ambayo inaweza kudhibitiwa umeme au umeme , daima maendeleo na kufunguliwa juu ya habari kwenye soko .

eHouse inaweza kudhibitiwa kwa mtawala IR kijijini (Sony standard) , PC , PDA , Simu za mkononi (Windows Simu 6 . 0 au Java MIDP 2 . 0) , Kugusa paneler msingi (Windows muziki 6 . 0 , Windows XP na waandamizi) au kwa kawaida ukuta vyema switches . Kudhibiti inaweza kupatikana via Bluetooth , Infra - Nyekundu (IR) , Ethernet , WiFi , eMail , SMS , ftp , faili nakala .

eHouse kutumia vifaa kawaida (switched on / off na RELAYS e . g . taa , pampu , cutouts , hita) , bila mantiki ndani kudhibiti na si zinahitaji vifaa ghali na ari (e . g . graphic paneler , kubadili paneler) .

eHouse inashirikiana na inaweza kuwa kusimamiwa na PC , ambayo inatoa nafasi ya kujenga programu mwenyewe overlays kwa ajili ya utekelezaji algorithms ya juu na mtu binafsi na kuchambua kumbukumbu na kufanya data kwa njia taka .

eHouse mfumo lina :


Byggelement tabia ya mfumo eHouse inawezesha kuchagua lahaja ya mtu binafsi ya ufungaji ambayo itakuwa yenye ufanisi , taka na mmiliki , na gharama nafuu .

E . g . watu ambao inajenga eHouse ufungaji katika gorofa au ghorofa si haja HeatManager mtawala , Roller mtawala . Wao kwa ujumla wanahitaji LevelManager au CommManager moja kwa moja gorofa ya kudhibiti , au RoomManagers kwa mtu binafsi kudhibiti joto katika vyumba na Audio / mifumo ya video .



eHouse inawezesha mfumo :


2 . 1 eHouse 1 chini ya usimamizi wa PC .

Ingawa wote controllers ya mfumo wa kufanya kazi binafsi bila PC kushikamana na mfumo wa , ongezeko mfumo PC funktionalitet na kudhibiti .

eHouse 1 anatumia PC pamoja na programu zinazotolewa " eHouse paket " (Windows XP na waandamizi) , imewekwa na kazi kama server ya mfumo na vingi - vyombo vya mawasiliano gateway . Maombi ya kuwawezesha kudhibiti kupitia mtandao , TCP / IP , WiFi (eHouse.exe) , Bluetooth (BlueGate.exe) , Barua pepe (EmailGate.exe) , FTP (FtpGate.exe) , SMS (SmsGate.exe) . Kuongeza mfumo inaweza kudhibitiwa na Windows Explorer (moja kwa moja tukio faili nakala) .

eHouse mfumo wanaweza kucheza kumbukumbu meddelanden redio ya hali ya mfumo na matukio (Player.exe) .

Masharti visualization maombi (Visual.exe) inaweza kudhibiti , taswira , na show majimbo ya vifaa kama graphics scalable na udhibiti kazi . Maoni inaweza kuwa mmoja mmoja aliumba katika Corel Draw maombi msaada wa kujenga utendaji jumla kwa kuingiza majina kutoka eHouse mfumo na picha ya kuzalisha kwa ajili ya mbinu nyingi visualization kutoka kwa mmoja kuchora .


Ehouse.exe maombi ni moyo wa mfumo wa akili nyumba ya PC . Wengi muhimu kazi ya maombi ni:



Ziada utendaji wa Programu paket


2 . 1 . Takwimu na mabasi ya nguvu ya eHouse 1 System .

Wote eHouse 1 vifaa ni kazi ya basi data (RS - 485 Kamili Duplex) . Tu vifaa kutoka mfumo eHouse yanaweza kushikamana na basi . PC kompyuta ni kushikamana na eHouse 1 bus via RS232 kubadilisha / RS485 , ambayo tafsiri TX , RX ishara ya tofauti (TX + , TX - , RX + , - ) Kwa ajili ya kuongeza mbalimbali (kwa kilomita 4) , kudumisha kasi ya transmissions (115,200) .

Kamili duplex mode kuongeza data throughput na kikomo migogoro ya basi . Jozi kila mwisho wa terminations tofauti basi lazima imewekwa (120 OM resistor) .



schematic1


Kama vifaa wengi kama 254 eHouse 1 yanaweza kushikamana na eHouse 1 bus . Vifaa lazima kushughulikia kipekee . Kila kifaa 2 Byte anwani ya kitambulisho (ADRH , ADRL) . Kila kifaa ni kabla - programed na default anwani (55 , 55) . Vifaa lazima kushikamana na mmoja wa basi kwa mmoja , na anwani lazima iliyopita kutoka default , mara baada ya uhusiano na thamani ya kipekee .

Na default (1 , 1) lazima kwa ajili ya HeatManager , (2 , 1) lazima kupewa kwa ExternalManager , vifaa (55 , 1 . 249) lazima kwa ajili ya RoomManagers . Anwani (254 , 254) ni zilizotengwa kwa CommManager .

Tarakimu 0 , 255 , 254 , 253 , 252 , 251 kamwe kutumika kwa Controllers eHouse .


eHouse 1 basi anatumia kiwango UTP - 8 cable . mistari 4 ni wakfu kwa mawasiliano (RX + , RX - , TX + , - ) . 4 mwingine ni kwa ajili ya driva Asili nguvu vifaa (2 * GND , 2 * 5V) . Matumizi ya voltage hii si ilipendekeza na thamani inaweza kuwa iliyopita katika matoleo mengine ya mfumo . mistari hii inaweza tu kutumika kwa driva RS232 / RS485 Converter .

Ya basi lazima kusambazwa serially si katika miundombinu ya nyota .


Nguvu basi anatumia 3 * 2 . 5mm2 cable kwa ajili ya kusambaza umeme kati ya wote eHouse 1 vifaa vya voltage (5 V , GND , 12 V) .

Bora chanzo cha nguvu ni PC Power ugavi (angalau 500W) ulinzi na 10a fuses katika mstari 12V na 5V . Sasa lazima mahesabu kwa mbaya kesi (relay kila ni akageuka juu) kuhesabu 20mA kwa relay na 300mA kwa Mtawala .

Katika kesi ya sasa ni ndogo mno ya chanzo ugavi nguvu mwingine unaweza kuwa kushikamana kinyume tarehe ya mwisho ya basi . Umeme lazima vizuri msingi wa kulinda eHouse mfumo dhidi ya uharibifu . Njia bora ni kuunganisha mwanzo na mwisho wa basi uwezo wa kuzuia uhusiano upinzani na voltage matone . Uingizaji hewa mzuri wa PC driva lazima kuhakikisha kuzuia kutoka overheating umeme au byte ni mbali na Thermal ulinzi .


Controllers lazima powered na mistari 12V na GND kwenye soketi nguvu . 5V mistari Mpya nguvu na basi lazima takwimu kukatwa .

5V inaweza kuwa tu kutumika kwa RELAYS driva (kama toleo 5V alikuwa kutumika) .


Katika kesi ya mabasi ya kuongoza nje ya nyumba , chini ya ardhi , au katika maeneo na kuongezeka unyevu wote nyaya lazima kutumia filimbi kama maji PE ulinzi .


Kabla mapya ya ufungaji wa kina wa mradi lazima umba likijumuisha maeneo ya vifaa kila mfumo , cable athari , sensorer , controllers , relay modules , swichi na paneli .

Wengi vipande muhimu ya nyaya lazima mara mbili kwa sababu za kiusalama .


PC lazima powered kutoka UPS kwa ajili ya kuhakikisha kuendelea kufanya kazi hata kama nguvu inashindwa .

Kuongeza inaweza kuwa powered parallelly kutoka 12V gari accumulator . Hata hivyo hii uhusiano lazima diodes imewekwa kati Power ugavi na eHouse Power basi , na kati ya accumulator na eHouse basi nguvu . Matumizi gari accumulator inaruhusu muda mrefu ya umeme kwa ajili ya Controllers , Usalama mfumo , Alarm Sensorer .



2 . eHouse 1 chini ya usimamizi wa CommManager .

Configuration hii CommManager nafasi PC , RS232 / RS485 Converter , ExternalManager , InputExtenders , Expander .

CommManager ina kujenga katika GSM moduli na tundu Ethernet . Hii lahaja ya mfumo inawezesha udhibiti kamili kupitia TCP / IP paneli kazi Windows XP , na Madirisha ya Mkono 6 . 0 na waandamizi wao (bila mahudhurio PC) . GSM moduli inawezesha meddelanden moja kwa moja SMS kutoka mfumo wa usalama na eHouse kudhibiti mfumo wa njia ya SMS , eMail via GPRS (piga - juu mtandao) .

Kuongeza mfumo inaweza kudhibitiwa kwa njia ya WiFi , LAN au Wan kutoka eHouse TCP / IP paneler .

Uhusiano ya CommManager na eHouse 1 basi lazima kuwa walifanya kwa RS - 485 kuvuka cable .

Ya signaler lazima kuwa na kushikamana kama katika meza ya:


CommManager eHouse 1

RX + TX +

RX - TX -

TX + RX +

TX - RX -

GND GND


eHouse Modules 1 bado anaweza kuwa kimeundwa kwa eHouse.exe maombi ziada vigezo / viatcp / extendedaddress / tcpquery .

/ Viatcp - eHouse maombi byte juu mode Uwazi kati Ethernet na eHouse 1 bus . majukumu mengine yote ya CommManager ni walemavu . mode Uwazi ni moja kwa moja baada ya deactivated Timeout (4 min) au vifaa restart ya CommManager . eHouse maombi ya kazi kama TCP / IP mteja dhidi ya RS - 485 UART .

/ Extendedaddress - kurudia kwenye mode kupanuliwa kushughulikia kwa eHouse modules 1 (kila moduli lazima kuwa chaguo " Kupitia Mawasiliano Moduli " kuwezeshwa katika eHouse.exe maombi .

/ Tcpquery kuwawezesha msaada kamili wa eHouse.exe maombi juu TCP / IP ikiwa ni pamoja na mbio matukio , querying vifaa , hifadhi ya hali yao (sawa funktionalitet kama kazi ya RS - 485 interface .



schematic2



2 . 3 . Ethernet eHouse (eHouse 2)

Hii lahaja ya ufungaji kazi chini ya TCP / IP miundombinu Ethernet (10Mbit) . Moja tu isipokuwa ni HeatManager ambayo bado ni kushikamana via RS - 485 kwa njia ya kuvuka cable . CommManager inashirikiana na LevelManagers , EthernetRoomManager ' s , TCP / IP paneli (Windows XP , Madirisha ya Mkono 6 . 0) kutumia eHouse itifaki na changamoto - majibu uthibitishaji sababu za usalama .



schematic3



3 . eHouse System Controllers .



3 . 1 RoomManager (RM) .


RoomManager (RM) ni kujitegemea zilizomo microcontroller na kujenga katika peripherals kwa kusimamia umeme , elektroniki vifaa katika chumba . Faraja na mitambo maximal anatumia 1 RM kwa kila chumba kuu (defined by user ambayo chumba ni muhimu) . Katika ufungaji za bajeti angalau kwa RM 1 ghorofa inahitajika . ufumbuzi huu kuweka baadhi ya kizuizi juu ya infrared Kudhibiti na kuweka mpango .


Kuu Utendaji wa RoomManager:


RoomManager inaweza configured na kusimamiwa na PC na imewekwa " eHouse.exe " maombi , ambayo inawezesha programu utendaji wote na chaguzi mtawala wa kujitegemea zilizomo moduli huru na wote wa ndani inaweza kuwa walifanya kazi ndani ya nchi bila ya mahudhurio ya PC .


RoomManager lina ya aina kadhaa tofauti ishara (ambayo ni pembejeo au matokeo) .

Kila signal ina matukio kadhaa binafsi na chaguzi yanayohusiana na hayo , kulingana na aina ya ishara .

Pembejeo signaler ni:

Pato signaler ni:


3 . 1 . Description signaler .


3 . 1 . Analog Pembejeo (ADC) .

Kila pembejeo Analog ina kazi <mbalimbali ; 0 ; 5V) na azimio 10 bits . Ni ina ngazi ya mtu mmoja mmoja kupewa voltage ndogo na maximal (ambayo anatoa 3 safu ya operesheni ADC) . Kuvuka ngazi hii itakuwa kuanzisha tukio moja kwa moja kukimbia defined na iliyowekwa na " eHouse.exe " maombi . Ngazi hizi ni kwa ajili ya kila mtu binafsi na Channel ADC kila mpango wa RoomManager .

Tatu matukio yanayohusiana na kila ADC kwa viwango vya kuvuka kwa kipimo maadili:


Kwanza pembejeo ni kwa ajili ya sensor ngazi ya Mwanga (photo transistor) au nyingine na inverted wadogo , pili sensor joto

Channel 3 - 8 kutumiwa na sensor joto au kufanya kazi nyingine katika kazi mbalimbali 0 - 5V .


(*) Kumtaja mkataba kutoka " eHouse.exe " maombi .




schematic4


3 . 1 . 2 . Digital Pembejeo .


Digital pembejeo kuchunguza viwango mantiki mbili (1 na 0) . Ili kuwahakikishia sahihi margin kosa pembejeo ina hysteresis 1V . Pembejeo kwa ajili ya usalama sababu ni Hadi kuvuta 5V nguvu ugavi , na shorting pembejeo chini mtawala signal kuamsha pembejeo sasa . Elektroniki sensorer na aina yoyote ya switches lazima kuwahakikishia ngazi hii juu ya mstari wa muda mrefu na bora ufumbuzi ni wakati vifaa ina kujenga katika relay na si kushikamana kuwasiliana (ambayo ni kushikamana na Pembejeo Mdhibiti kama kubadili kawaida) . Hali hii huonyesha kiwango sahihi voltage na vifaa tofauti ambayo inaweza kuwa powered kutoka vifaa vingine salama . Vinginevyo , ugavi thamani tofauti au malfunction sensor huweza kudumu uharibifu wa mtawala pembejeo au wote .


Kuna ni mbili tukio defined kwa kila mchango juu ya hali ya kubadilisha:



schematic5



3 . 1 . 3 . Matokeo ya digital


Digital matokeo ya moja kwa moja unaweza kuendesha gari RELAYS Module na ni inaweza kuweka mantiki majimbo 0 na 1 (kugeuka mbali na mawasiliano relay) . Tukio kupewa kwa matokeo ni:

Ni unaweza kuwa na kukimbia kama:



schematic6


3 . 1 . 5 . PWM (Pulse upana Modulated) Matokeo .


PWM Pato ni DC dimmers , ambayo variable wajibu mzunguko (na 8 bits azimio) .


schematic20


PWM matokeo pamoja na madereva Power imewekwa kwa hiari kwenye Relay Module , inaweza kudhibiti fluently (255 nafasi) ngazi ya mwanga wa taa powered 12V/DC - 30W . Hatimaye nje ya uwezo wa madereva na opto - isolator juu pembejeo , inaweza kutumika kwa gari nguvu juu na mizigo kufata (e . g . DC motors , ventilators , pampu) .

PWM pato la RM , EM , HM ni uwezo na gari 1 LED kushikamana moja kwa moja kama element ya opto - isolator . Opto - isolator ni lazima ya kulinda Mtawala dhidi ya uharibifu wa kudumu wa mfumo mzima unasababishwa na kuharibika .



Uhusiano mfano wa nje madereva nguvu PWM na eHouse System .



schematic8



Uhusiano lazima barabara kama mfupi iwezekanavyo .


3 . 1 . 6 . IR Remote Udhibiti wa RoomManager .


Kila RoomManager inaweza kudhibitiwa kwa kiwango mtawala IR Sony kijijini (SIRC) . Kijijini Mdhibiti inawezesha:

hawawajui ya tukio moja kwa moja mitaa Remote vifungo Mdhibiti inaweza kuwa walifanya mmoja mmoja .


Default Mdhibiti kijijini aina ni Sony RMT - V260A (anatumia VIDEO 2 kuweka) .

Kuzingatia idadi ya kazi kubwa katika mfumo , mtawala kijijini lazima kama vifungo wengi iwezekanavyo (pamoja na kubadili ndani kwa ajili ya kubadilisha vifaa) .


Default kijijini mtawala button utendaji (kabla ya - configured kuweka VIDEO 2) .


Kifungo Kazi

Wazi Cancel

0 - 9 0 - 9 kuchagua NR ya pembejeo , pato , ADC Channel , PWM Channel

Kucheza ON

Kuacha OFF

gurudumu + +

gurudumu - -

TV / Video Joto (Ngazi)

Kuonyesha Mwanga (Ngazi)

Pembejeo Kuchagua Digital Outs

Audio Kufuatilia Analog Input (Ngazi)

Rec Reset sasa RoomManager (zinahitaji kubwa OK pia)

OK Kipaimara ya upya na kubadilisha mpango

Nguvu Toggle (Switch kwa ngazi nyingine)

Smart Picha Programu ya Uchaguzi (kimataifa ufafanuzi kwa sasa max RM 24 mipango)

Orodha ya Kudhibiti nyingine RoomManager (pato tu inaweza kubadilishwa) [" Menu " + Nr_of_RoomManager

+ " OK " + " Pembejeo Select " + OutputNr + ON / OFF / Toggle]

Pause Winamp (Play)

SAT Winamp (Stop)

Index Winamp ijayo (Next Track)

Index Winamp uliopita (Previous Track)

SP / LP Winamp (Shuffle)

Upana Winamp (Repeat)

Ujazo + Winamp (Volume +)

Ujazo - Winamp (Volume - )


Kijijini Mtawala matumizi itawezesha utekelezaji wa tukio lolote , ila kubadilisha Configuration na kipanya toleo .


Hatua kwa ajili ya kudhibiti IR:

1 . Kuchagua Mode:

2 . Kuchagua channel NR:

0 . max

3 . Change thamani

(E . g . Mwanga Level , Channel 1 , + , + , +)


RoomManager inapuuzia kubwa ya kifungo kwa muda mrefu hivyo lazima + taabu mara nyingi kubadili kiwango inatarajiwa .


Kuna uwezekano wa matumizi controllers zima kijijini (pamoja na kujengwa - katika Sony kiwango msaada) , na LCD kugusa jopo (e . g . Fikra , Logitech {Harmony}) na kujenga taka Configuration maelezo na mtawala kijijini kujenga IR Control Panel kwa eHouse Management .


Badala ya ari kifungo kwa ajili ya kudhibiti , kuna uwezekano wa hawawajui yoyote mitaa RoomManager tukio vifungo bure inapatikana katika Remote Mtawala (max 200) . Kuna uwezekano wa kudhibiti Audio mbalimbali / Video , HiFi mfumo via mtawala Single Sony Remote , na assigning wengi utendaji kifungo .


Kubadilisha pato serikali (ON / OFF) .


1 . Waandishi wa habari (Input Chagua) kifungo mtawala kijijini

2 . Vyombo vya habari NR 0 . 24

3 Kuchagua taka hali


Mifano:

(Pembejeo Kuchagua) - > (1) - > (3) - > (Play) = Output 13 ON

(Pembejeo Kuchagua) - > (7) - > (Stop) = Output 7 OFF

(Pembejeo Kuchagua) - > (1) - > (7) - > (Power) = Output 17 Change State


Mabadiliko ya Mpango RoomManager .


1 . Waandishi wa habari (Smart Picha)

2 . Kuchagua NR 1 . 24

3 . Waandishi wa habari (OK)


Mifano:

(Smart Picha) - > (1) - > (3) - > (OK) = Chagua Programu ya 13

(Smart Picha) - > (7) - > (OK) = Chagua Programu ya 7

(Smart Picha) - > (1) - > (7) - > (OK) = Chagua Programu ya 17


Shifting ADC Ngazi .


1 . Waandishi wa habari (Audio Monitor)

2 . Kuchagua channel 1 . 8

3 . Kugeuka gurudumu (+) au ( - ) (1 Pulse = kuhama ca 5mV , kwa takriban Temp 0 . 5 shahada) .


Mfano kuongeza inapokanzwa kuhusu 1 . 5 shahada , kudhibitiwa na ADC channel 2

1 . (Audio kufuatilia) - > (2) - > (Wheel +) - > (Wheel +) - > (Wheel +)


Mwanga Ngazi ya Udhibiti .

1 . Waandishi wa habari (Display)

2 . Alichagua dimmer Channel:

3 . Kuchagua mode ,

4 . (OFF) .

Kwa Dimmer namba:

4 (Toggle) .

Kwa Dimmer Idadi:

1 - 3 - > kama Mwanga Level ni 0 kuanza brightening kuchaguliwa dimmer vinginevyo kuanzisha dimming .

4 (ON) .

Kwa Dimmer Idadi:

4 ( - ) .

Kwa Dimmer Idadi:

0 - > kubadili mbali pato mwisho (mwanga kundi) ,

1 - 3 - > kuanza dimming ya kuchaguliwa PWM dimmer (chini ya Min Thamani au mwongozo kuacha) ,

9 - > kuanza dimming zote PWM Dimmers (chini ya Min thamani au mwongozo kuacha)

4 . (+) .

Kwa Dimmer Idadi:

Mifano:

(Display) - > (1) - > (+) - > . (Kuchelewa e . g . 10s) . - > (Stop) - Kuanza brightening PWM dimmer 1 na kuacha baada ya 10s

(Display) - > (9) - > (+) - Kuanza brightening Dimmers PWM wote hadi Max Maadili .

(Display) - > (+) - Kurejea kwenye NR ijayo pato (ijayo mwanga kundi)

(Display) - > ( - ) - Kugeuka mbali sasa pato NR (sasa mwanga kundi)

(Display) - > (9) - > ( - ) - > (Kuchelewa) - > > - > (1) - > (Stop) - kuanza dimming wote Dimmers PWM , kuacha PWM dimmer 1 , katika taka nafasi nyingine PWM Dimmers mapenzi fade nje chini ya Ongezeko la Thamani Ndogo .


Kudhibiti nyingine RoomManager matokeo .


Kudhibiti inawezekana tu juu PC server eHouse .

1 . Waandishi wa habari (Menu) ,

2 . Kuchagua (Address Low) ya taka RoomManager ,

3 . Waandishi wa habari (OK) ,

4 . Kutekeleza hatua kama kwa RoomManager mitaa

(Pembejeo Kuchagua - > (Output NR) - (Power au Play au Stop)

5 . Kudhibiti kwa RM mitaa kurejeshwa baada ya dakika ya kuto 2 kijijini mtawala au uteuzi mwongozo wa RoomManager NR 0 .


Mifano

(Menu) - > (2) - > (OK) Kuchagua RoomManager (na anwani = 55 , 2)

(Pembejeo Kuchagua) - > (1) - > (2) - > (Power) Mabadiliko ya hali ya Pato 12 ya kuchaguliwa RM

(Pembejeo Kuchagua) - > (1) - > (0) - > (Play) Turn On Output 10 ya kuchaguliwa RM

(Pembejeo Kuchagua) - > (4) - > (Stop) Turn Off Output 4 ya kuchaguliwa RM

(Menu) - > (OK) Kurejesha mitaa RM uteuzi .




Wakati kubadilisha kazi , NR ya nje , pembejeo , mpango , nk daima reset 0 , hivyo si lazima kuchagua 0 kama haya (Menu) - > (0) - > (OK)




Kusimamia Winamp Maombi .


Winamp maombi lazima imewekwa na mbio eHouse Server PC . eHouse maombi lazima kazi daima . Winamp ni kudhibitiwa via IR (Sony kijijini mtawala) kupitia RoomManager .


Predefined kijijini mtawala vifungo na kazi zao:


RC Kazi button

Pause Winamp (Play) au kurudia kufuatilia sasa ,

SAT Winamp (Stop) fade nje na kuacha ,

Index Winamp ijayo (Next Track) ,

Index Winamp uliopita (Previous Track)

> ; Winamp (FF) Forward sekunde chache

< ; Winamp (Rewind) Rewind sekunde chache

SP / LP Winamp (Shuffle) Toggle Shuffle mode

Upana Winamp (Repeat) Toggle Repeat

Ujazo + Winamp (Volume +) Kuongeza Volume 1%

- Winamp (Volume - ) Upungufu Volume 1%


. Assigning matukio ya RoomManager mitaa Remote Mdhibiti Buttons .

RoomManager ina kujenga katika kazi kwa ajili ya tukio utekelezaji wa ndani juu ya uendelezaji programmerad button ya mtawala kijijini max ( . 200 matukio ya vifungo zoezi inawezekana) .

Na kujenga ufafanuzi wa vifungo kijijini mtawala:


Kudhibiti wa vifaa nje (Audio / Video / HiFi) kupitia IR mtawala Remote kificho wivu .

RoomManager vyenye IR transmitter na kujenga katika mantiki ya kupeleka ishara IR katika viwango vya wengi mtengenezaji .

Wao inaweza alitekwa , kujifunza na kucheza (hadi 248 kwa kila namba RM) . Baada ya kukamata IR code , eHouse matukio ni umba . Hii inaweza matukio lazima ifanyike kwa njia nyingi .


3 . Kufafanua codes Remote , kudhibiti vifaa nje .


Katika ili kujenga na kuongeza IR Remote Mdhibiti kanuni kwa ajili ya usimamizi wa nje ya vifaa (TV , HiFi , Video , DVD nk) chini ya usimamizi wa kuchaguliwa RoomManager , hatua zifuatazo wanapaswa kuwa walifanya:


4 . Kujenga macros - baadae 1 na 4 kijijini codes kunyonga .

usimamizi ya kuchaguliwa RoomManager , hatua zifuatazo wanapaswa kuwa walifanya:


Wachache viwango vya aina kadhaa IR Remote Controllers ni mkono na RoomManager (lazima kuthibitishwa na kifaa kupima na kijijini mtawala) . Kuhakikiwa viwango ni (Sony , Mitsubishi , AIWA , Samsung , Daewoo , Panasonic , Matsumi , Nokia na wengi zaidi) . Njia bora ni kuamua juu ya mmoja wa Mtengenezaji Audio / vifaa Video .



3 . 1 . 7 . Kudhibiti na ndogo - miniatyr IR / RF kijijini mtawala (elektroniki muhimu)

eHouse mfumo inasaidia pia funguo za elektroniki (IR Infra - Nyekundu na redio Frequency RF) , vyenye vifungo 4 .

Kubwa chini kifungo uzinduzi IR kanuni kwa ajili ya kubadilisha mpango wa sasa RoomManager (sawa na mlolongo wa vifungo kubwa katika Sony RC (SmartFile> ProgramNR 1> OK) . Maelezo lazima umba katika RoomManager au " eHouse.exe " maombi .


3 . 1 . 2 . Ugani modules kwa RoomManager .

3 . 1 . 2 . 1 Bluetooth Module .

RoomManager wanaweza kushirikiana na Bluetooth , kwa kupokea amri Bluetooth kwa eHouse 1 mfumo . Inaweza kutumika kwa ajili ya kueneza mbalimbali ya Bluetooth juu nyumba . Wote kutumika modules BT lazima paired pamoja na vifaa kwa ajili ya kutuma Bluetooth amri (PDA , simu za) . Password (" BT Password " *), Na kiambishi awali ya kifaa jina (" BT Jeshi " *) Kwa ajili ya moduli Bluetooth ni defined katika eHouse.exe maombi . Ni inafanya uwezekano wa kutambua vifaa BT ya idhini ya kuwezesha na kuongeza usalama wa uhusiano .


3 . 1 . 2 . Mifare Upatikanaji Kadi Reader .

RoomManager wanaweza kushirikiana na Mifare Kadi Reader . Hii itawezesha kupata ufumbuzi kudhibiti , haki ya vikwazo , udhibiti wa kiwango cha juu . Ni hasa kusaidia katika hoteli , majengo ya umma , ofisi , upatikanaji wa kudhibiti maombi .

Kufunga kadi na msomaji ni watumiaji kwenye PC eHouse Server na tukio programmerad inaweza kuwa ilizindua (e . g . kufungua mlango)

Kama kadi ya mara ulioamilishwa katika mfumo mask eHouse kupata haki ni mabadiliko kwa sasa RoomManager .

Upatikanaji haki inaweza kuweka kwenye:


Ni inawezekana kuweka matokeo programmerad (kwa ajili ya 10s) e . g . kwa ajili ya kufungua electro - sumaku , signal kizazi , uthibitisho taa .

Upatikanaji haki pamoja na matokeo ya wakfu ni mmoja mmoja programmerad kwa kila Kadi Mifare . Jina kwa kila kadi inaweza pia defined .



3 . 2 ExternalManager - Roller Mdhibiti


ExternalManager ni muundo wa RoomManager na kuruhusu udhibiti wa rollers , milango , milango , kivuli awnings . Pamoja na InputExtender kulinda nyumba na majengo kwa njia salama sana kwa sababu ni kudhibitiwa nje ufuatiliaji wa eneo (na wala kutoa muda zaidi kwa ajili ya Intruders) . Ni inaweza kudhibitiwa via mtawala salama kijijini (kwa kutumia nguvu KEELOQ kificho algorithm na microchip) , ambayo ni kawaida kutumika katika usalama mzuri mifumo ya . Matukio Alarm ni ulianzishwa mara moja , bila kuchelewa nini hufanyika katika mifumo ya vifaa katika keyboards , ziko ndani ya nyumba . Mfumo wa usalama zituma meddelanden SMS:


kwa mbili kikundi cha watu (watendaji na waandishi wa habari) .


Watendaji kundi kupokea:


Waandishi wa habari kundi kupokea (inaweza kuwa majirani , polisi , usalama , ufuatiliaji shirika):


Kuu tofauti kutoka RoomManager ni:


ExternalManager pia ni iliyowekwa na configured na " eHouse.exe " maombi . Kifaa binafsi zilizomo ndani ya nchi na wanaweza kufanya kazi bila kompyuta mahudhurio .

Kutokana na similarity kubwa RoomManager tofauti tu itakuwa alielezea .


3 . 2 . 1 . Signaler maelezo .


3 . 2 . 1 . Rollers , milango , milango anatoa matokeo .

Haya matokeo ni jozi ya matokeo kwa ajili ya kuendesha rollers , milango , milango anatoa katika kiwango SOMFY (default kuweka) au anatoa moja kwa moja .

Kuna uwezekano wa kudhibiti hadi rollers 13 wa kujitegemea , milango na milango mifumo .

Kila roller channel katika SOMFY kiwango = Roller Open (1 sec Pulse juu ya A pato) , Roller Close (1 sec Pulse juu ya uzalishaji B) , Kuacha (1 sec Pulse juu zote mbili A na matokeo B} .

matokeo pia inaweza kutumika kwa ajili ya kudhibiti moja kwa moja ya anatoa motor (kuendesha Mpya A kwa ajili ya kuhamia katika mwelekeo mmoja , kuendesha line B kwa ajili ya kuhamia katika nyingine mwelekeo) . Anatoa lazima kujenga wenyewe katika ulinzi dhidi ya kurudia kwenye wawili maagizo , block rollers , mwisho switches , kasi ya ulinzi nk . Vinginevyo katika kesi ya malfunction ya relay , Configuration makosa ya moduli , kuzuia gari na baridi au hujuma , inawezekana gari uharibifu . Mfumo imejenga - katika Programu ya ulinzi dhidi ya kuhamia mwelekeo wote wakati huo muda , lakini anaweza ' t kuangalia kama gari itafikia mwisho au wasn ' t blocked na ISN ' t kutosha kulinda rollers . mode Hii inaweza tu kutumika katika mwenyewe hatari na kampuni iSys si kuwajibika kwa uharibifu wa anatoa . Mfumo tu Somfy inaweza kutumika kwa usalama kwa sababu ni kuhusisha mwenyewe ulinzi wa anatoa .



Uhusiano ya Rollers , Milango , Milango Drives


schematic9



3 . 2 . 1 . 2 . PWM (Pulse upana Modulated) Matokeo .


PWM DC dimmers pato ni matokeo ambayo variable wajibu mzunguko (na 8 bits wa awali) .



PWM matokeo pamoja na madereva Power imewekwa kwa hiari kwenye Relay Module , inaweza kudhibiti fluently (255 nafasi) ngazi ya mwanga wa taa powered 12V/DC - 30W . Hatimaye nje Power madereva na opto - isolator juu pembejeo inaweza kutumika kwa gari High Nguvu na mizigo kufata (e . g . DC Motors , Ventilators , Pampu) .

PWM pato la RM , EM , HM ni uwezo na gari 1 LED kushikamana moja kwa moja kama element ya opto - isolator . Opto - isolator ni lazima , kulinda mtawala dhidi ya uharibifu wa kudumu wa mfumo mzima unasababishwa na kuharibika .


Uhusiano mfano wa nje madereva nguvu PWM na mfumo eHouse .



schematic11



Uhusiano na Module RELAYS lazima barabara kama mfupi iwezekanavyo .



3 . 2 . 1 . 3 . Matokeo ya digital .

ExternalManager have 2 matokeo kiwango sawa na RoomManager . pato Hii inaweza kuwa kuweka 1 mantiki , 0 , muda 1 (kuhusu 2 sec) au kufanya mabadiliko . Ni inaweza kutumika kwa ajili ya kulala nje ya misingi ya umeme nk .


3 . 2 . 1 . 4 . Digital Pembejeo .

ExternalManager na wajumbe wa pembejeo 12 digital sawa na RoomManager . Matukio ya mitaa ExternalManager inaweza kuwa na kupewa kwa mataifa ya pembejeo hii .


3 . 2 . 1 . 5 . Analog pembejeo .

Kila pembejeo Analog ina kazi <mbalimbali ; 0 ; 5V) na azimio 10 bits . Ni ina ngazi ya mtu mmoja mmoja kupewa voltage ndogo na maximal (ambayo anatoa 3 safu ya operesheni ADC) . Kuvuka ngazi hii itakuwa kuanzisha tukio moja kwa moja kukimbia , defined na iliyowekwa na " eHouse.exe " maombi . Ngazi hizi ni kwa ajili ya kila mtu binafsi na Channel ADC kila mpango wa RoomManager .

Tatu matukio yanayohusiana na kila ADC kwa kuvuka maadili kipimo:



(*) Kumtaja mkataba kutoka " eHouse.exe maombi .


3 . 2 . Moja kwa moja za kudhibiti na RF elektroniki muhimu .


ExternalManager inaweza kudhibitiwa ndani ya nchi na muhimu za elektroniki (RF kijijini mtawala - 100 m maximal mbalimbali katika eneo wazi) .


RF Kijijini Controllers inaweza kuongeza na kuondoa mmoja mmoja katika eHouse maombi , nini ni vizuri sana katika kesi ya kupoteza au kuiba moja kijijini . Mbalimbali ya RC ni max . 100 m katika shamba wazi . Kwa kila kifungo mchanganyiko na kila Mdhibiti Remote , Rollers mazingira pamoja pamoja na mabadiliko eneo inaweza kupewa .
Mipango unaweza kuelezwa mmoja mmoja kwa kila mchanganyiko wa vifungo na mtawala kijijini (E . g . kwa ajili ya watoto , usalama wa shirika , mkulima , nk . ) .


Kutuma wa kanuni RF ni ulianzishwa wakati baadhi ya mchanganyiko wa vifungo wengine watatu ni kushikilia wakati nguvu kubwa button .

Katika kesi ya muhimu RF signal elektroniki anatumia nguvu KEELOQ code msingi leseni ya shirika microchip . Kila muhimu za elektroniki lazima aliongeza eHouse ndani ya maombi katika " Nje Meneja " * Tab kwa ExternalManager kifaa .

Zifuatazo hatua lazima kuwa walifanya ya kufanya hivyo:


Kuongeza ExternalManager RF vifungo mipango (Rollers , matokeo , eneo settings) inaweza kupewa kwa macho yoyote ya kifungo mmoja mmoja kwa kila elektroniki muhimu .

Zifuatazo hatua lazima kuwa walifanya ya kufanya hivyo:


Binafsi RF Button mipango ya muhimu kila elektroniki inatoa fursa , kupita kijijini controllers kwa watoto , huduma ya wafanyakazi , ufuatiliaji au usalama shirika , bustani na haki mdogo sana (e . g . kubadilisha tu usalama wa eneo na kufungua mlango ili kuwezesha majengo ya kuingia na kuangalia kama kila kitu ni sawa .




3 . HeatManager - Boiler Room na joto ya Kati mtawala

HeatManager ni ubinafsi zilizomo mtawala wa kusimamia:

Kifaa inaweza kudhibiti advanced sana na baridi inapokanzwa na ufungaji pamoja na matumizi ya bure na Chip vyanzo vya nishati umakini inapunguza gharama ya joto na baridi , kufanya nini inawezekana refund gharama ya ufungaji katika 1 - 3 miaka .

Kutokana na HeatManager kubwa sana funktionalitet inaweza kupitisha na kukanza yoyote / kylning ufungaji Configuration .

Kuu kazi ni:


Mtawala kupima na kudhibiti joto zifuatazo:


Nje joto Kaskazini (inaweza kuchukuliwa kutoka RoomManager programmerad)

Nje joto Kusini (inaweza kuchukuliwa kutoka RoomManager programmerad)

Ndani joto la kawaida (inaweza kuchukuliwa kutoka RoomManager programmerad)


3 . 1 . HeatManager Matokeo .


3 Pato - Nakala ya bonfire (kwa ajili ya taa kwa sasa) Green / Yellow / Red

Taa macho inategemea ya joto ya maji Jacket na convection .

Tjacket - kipimo maji Jacket joto (mara mbili)

Tconv - kipimo convection joto hapo juu bonfire

Wote kugeuka mbali - Tconv < " Conv . Mbali " * , na Tjacket < " Nyekundu " * .

Kijani Blinking - Tupu bonfire au kutaa mbali (Tjacket < " Kijani " *) Na (" Conv . Mbali " * < Tconv < " Conv . Juu " *)

Kijani kuendelea - " Kijani " * < Tjacket < " Njano " * - " Margin " *

Kijani na Yellow - " Njano " * - " Margin " * < Tjacket < " Njano " * + " Margin " *

Njano - " Njano " * + " Margin " * < Tjacket < " Nyekundu " * - " Margin " *

Njano na Red - " Nyekundu " * - " Margin " * < Tjacket < " Nyekundu " * + " Margin " *

Nyekundu - " Nyekundu " * + " Margin " * < Tjacket < " Alarm " *

Nyekundu Blinking - Tjacket>= " Alarm " *


Bonfire Maji Pump (kati bonfire maji Jacket na Moto Maji Buffer) .


Tjacket = Average (T Jacket 1 na T Jacket 2) kipimo

Tconv = Kipimo convection joto hapo juu bonfire

Tjacket > " Bonfire Pump " * Na Tconv> " Conv . mbali " * (Bonfire ni inapokanzwa) (Pump Juu)

Tjacket < " Bonfire Pump " * - " Margin " * (Pump Off)


Boiler Maji Pump (kati Boiler maji Jacket na Moto Maji Buffer)

Tboiler> " Boiler Pampu " * (Pump Juu)

Tboiler < " Boiler Pampu " * - " Margin " * (Pump Off)


Boiler ON / OFF kudhibitiwa na joto la Moto Maji Buffer .

Tbm - Kipimo joto ya katikati buffer

Tbm > " Min T " * (Boiler OFF)

Tbm < " Min T " * - " Margin " * Na na mbali ya nishati ya jua bonfire mbali (Boiler ILIYO)


Recuperator (Hewa ON / OFF) .

Tint - kipimo sensor ya Kati Kukanza Internal joto

Tint > " T tafsiri " * (Kukanza Mode - Vent OFF mwongozo au mfumo kamili auto) ,

Tint < " T tafsiri " * - " Margin " * (Kukanza Mode - Vent juu ya mwongozo au mfumo kamili auto) ,

Tint > " T tafsiri " * (Kylning Mode - Vent juu ya mwongozo au full auto mode) ,

Tint < " T tafsiri " * - " Margin " * (Kylning Mode - Vent OFF mwongozo au mfumo kamili auto) .


Recuperator (Level 1 / Level 2 / Level 3) .

Kudhibiti Uingizaji hewa Level mwenyewe au kutokana na kipanya .


Maji Heater Pump (kati buffer na heater) .

Tint - kipimo sensor ya Kati Kukanza Internal joto

Tint < T tafsiri * - Margin * (Kukanza mode - Pampu ILIYO)

Tint > T tafsiri * (Pump OFF)


(*) Maji heater / COOLER Pump kwa GHE .

Pampu ni akageuka juu wakati uingizaji hewa , recuperation via GHE ni bomba na hali ya ziada ni alikutana:


Tatu njia cutout kudhibiti (+) (kati ya Moto Maji Buffer na Maji heater) .

Theat - Kipimo cha joto la Air baada ya Maji heater .

Theat > " T heater " * (Off)

Theat < " T heater " * - " Margin " * (Muda juu) wakati wa hewa katika inapokanzwa mode .


Tatu njia cutout kudhibiti ( - ) (Kati ya Moto Maji Buffer na Maji heater) .

Theat - Kipimo cha joto la Air baada ya Maji heater .

Theat > " T heater " * (Muda juu) wakati hewa katika inapokanzwa mode .

Theat < " T heater " * - " T hist " * (OFF)


Maalum algorithm makadirio alikuwa kutekelezwa kwa muda wa harakati za kudhibiti cutout umeme kuweka heater joto katika ngazi ya taka kutegemea kwenye Moto Maji joto Buffer , delta ya joto na kadhalika .


Nishati ya jua Mfumo wa Maji Pump (kati ya mfumo wa jua na Moto Maji Buffer) .

T Nishati ya jua (kipimo)> " T Solar " * (ON) ,

T Nishati ya jua (kipimo) < " T Solar " * - " Margin " * (OFF) ,


Boiler Nguvu (On / Off) .

Unaweza kutumika kwa kugeuza nguvu ya Boiler katika majira ya joto , nk .


Boiler mlemavu mafuta ya ugavi wa gari (On / Off) .

Mafuta gari ugavi inaweza kuwa nje walemavu na HeatManager e . g . kwa flash nje wote mafuta katika eneo la moto Boiler . Hasa kwa ajili ya nishati imara driver .


Override mafuta ya gari ugavi (On / Off) .

Mafuta gari ugavi inaweza kuwa nje overriden na HeatManager e . g . kwa ajili ya shehena mafuta kwa mara ya kwanza au baada ya flash nje . Hasa kwa ajili ya nishati imara driver .


Bonfire Moto Air Distribution blower (alikuwa System)

Tconv = Kipimo joto thamani ya convection juu bonfire .

Tconv > " Conv . Juu " * (Tarehe) ,

Tconv < " Conv . Mbali " * (Off) .


Moto Maji Buffer sasa .

TBD , Tbm , Tbt - Kipimo joto ya buffer mtiririko (chini , katikati , juu) .

TBD > " T buffer min " * (Kuendelea taa)

T wastani buffer> 100% Short wakati mbali kulinganisha na muda .

wastani buffer < 100% Uwiano juu kwa muda off .

0 . 2 sec na TIME_OFF (Tbt + Tbm) / 2 chini kisha 45 C - kutosha kwa ajili ya kuchemshia maji .

TIME_ON = TIME_OFF 0 . 2 sec (Tbt) < " T heater " * 5 C si kutosha joto kwa inapokanzwa (maji heater usambazaji) .


Boiler Alarm .

T Boiler kipimo> " T alarm " * (Tarehe)

T Boiler kipimo < " T alarm " * (Off)



* matumizi ya kumtaja kutoka " eHouse.exe " maombi ya vigezo .


3 . 2 . HeatManager Matukio .

HeatManager ni kujitolea mtawala kwa inapokanzwa , baridi , uingizaji hewa kazi katika wengi modes . Katika nyingine kufikia funktionalitet kamili na ndogo za binadamu mwingiliano , ari seti ya tukio alikuwa defined , kufanya wake wote utendaji . Inaweza kuwa na kukimbia mwenyewe au kutoka kipanya advanced (248 nafasi) kujenga katika HeatManager kama katika vifaa vingine ya mfumo eHouse .

Matukio ya HeatManager:



* PWM inaweza kudhibiti mashabiki ziada DC au vifaa vingine kudhibitiwa (Pulse upana modulated pembejeo) . Nguvu ya ziada inahitajika dereva na opto - kutengwa .


Ari Recuperator Matukio (AMALVA REGO - 400) au nyingine (*)


(*) Udhibiti wa moja kwa moja recuperator unaweza kuhitaji kuingiliwa ndani ndani mzunguko wa recuperator (moja kwa moja na uhusiano na mashabiki , bypass , Kasi Trafo , nk .

iSys kampuni si wajibu kwa yeyote uharibifu ambayo hutokea katika aina hii ya kazi .

Recuperator Amalva haja cable uhusiano kwa HeatManager yanayopangwa ugani (UART2) Serial kujengwa kwa bandari - katika katika REGO bodi .

Sahihi kutuliza lazima kuundwa kwa wote ulinzi wa vifaa .


HeatManager inasaidia mipango ya 24 kwa ajili ya kazi unattended . Kila mpango na wajumbe wote joto ngazi , uingizaji hewa , recuperation modes . HeatManager moja kwa moja kurekebisha inapokanzwa na uingizaji hewa vigezo kupata taka joto katika njia zaidi ya kiuchumi . Pampu wote ni moja kwa moja kurejea kwenye / off ufuatiliaji ngazi programed ya joto .

Mipango wanaweza kukimbia manually kutoka " eHouse " maombi au kukimbia moja kwa moja kutoka kipanya advanced kuruhusu kwa ajili ya msimu , mwezi , muda , nk marekebisho kwa ajili ya kudhibiti kuu inapokanzwa mfumo na uingizaji hewa .


3 . Uingizaji hewa , recuperation , inapokanzwa , kylning modes .


Moto Distribution hewa kutoka bonfire (alikuwa) - Ni kurejea kwenye moja kwa moja na kujitegemea na masharti mengine ya joto na baridi , kama bonfire ni inapokanzwa na chaguo hili ni kazi kwa ajili ya mpango wa sasa wa HeatManager .


Mwongozo Mode - Kila vigezo: uingizaji hewa , recuperation , inapokanzwa , baridi , ni preset manually katika mazingira ya mpango (uingizaji hewa ngazi , baridi , inapokanzwa , recuperator joto exchanger , joto ardhini exchanger , joto ya inapokanzwa , joto aliomba .

Katika kesi ya joto ndani ya chumba overstep wakati wa kukanza - uingizaji hewa , inapokanzwa recuperation , na kazi msaidizi ni kusimamishwa na kuanza wakati ndani ya joto chini ya matone thamani " T requested " * - " Margin " * .


Kamili Auto Mode - Required kiwango cha joto uingizaji hewa na heater ni preset katika mazingira ya mpango . Wote mazingira mengine ni kubadilishwa moja kwa moja na kudumisha aliomba joto katika chumba , na joto au baridi . Wakati wa kukanza , HeatManager anayeshika heater joto juu programmerad ngazi , kurekebisha umeme njia tatu cutout . HeatManager inao required joto kwa gharama ya chini ya nishati kutumika , byte moja kwa moja na mbali msaidizi vifaa kama mashabiki , ardhi joto exchanger , baridi , heater . Katika kesi ya overstep aliomba uingizaji hewa joto , inapokanzwa na vifaa vyote msaidizi ataacha . Uingizaji hewa , recuperation , inapokanzwa ni yalianza wakati ndani ya chumba joto matone chini " T aliomba " * - " Margin " * .


Katika kylning mode katika kesi ya joto ndani ya chumba kushuka chini " T requested " * - " Margin " * Uingizaji hewa , recuperation , baridi na vifaa msaidizi kuacha pia . Yao ni yalianza wakati joto overstep " T aliomba " * Thamani .

Masharti Uingizaji hewa Mode . Masharti ya uingizaji hewa mode imechukuliwa fomu full auto mode - na uingizaji hewa uninterrupted na recuperation . Uingizaji hewa , recuperation kazi wakati wote kudumisha ndani joto katika ngazi ya taka . Katika kesi ya ndani ya chumba overstep joto wakati wa kukanza mode , au kushuka chini wakati kylning mode heater , baridi , uingizaji hewa , vifaa msaidizi ni kuweka na nishati ya kuokoa mode , na uingizaji hewa makofi hewa safi na mojawapo joto la wastani wa sawa na T ombi katika chumba . Nje joto ni kuchukuliwa , kuongeza ufanisi wa mfumo .



HeatManager Moduli pini eneo .


Kontakt J4 - Analog pembejeo (IDC - 20) kwa ajili ya moja kwa moja sensorer joto uhusiano (LM335)


Sensor PIN J4 Description joto sensor

Ardhi - GND (0V) 1 Common siri kwa ajili ya kuunganisha LM335 wote joto sensorer

Ardhi - GND (0V) 2 Common siri kwa ajili ya kuunganisha LM335 wote joto sensorer

ADC_Buffer_Middle 3 50%

ADC_External_N * 4 Nje Kaskazini (Je, kuwa na kuchukuliwa kutoka meneja programmerad chumba

kama sensor si zimeunganishwa ndani ya nchi inahitaji Online PC uhusiano

na eHouse.exe maombi ya mbio kuendelea) .

ADC_External_S * 5 Nje Kusini (Je, kuwa na kuchukuliwa kutoka RoomManager programmerad

kama sensor si zimeunganishwa ndani ya nchi . Inahitaji Online PC uhusiano

na eHouse.exe maombi ya msaada) .

ADC_Solar 6 Sola mfumo (juu kumweka) .

ADC_Buffer_Top 7 90% urefu wa Maji Moto Buffer (kwa ajili ya mchakato wa kudhibiti inapokanzwa) .

Jacket wa boiler - pato bomba (kwa ajili ya pampu kudhibiti boiler) .

ADC_GHE 9 Ground Joto Exchanger (udhibiti wa GHE katika Auto Kamili

au masharti ya uingizaji hewa modes)

ADC_Buffer_Bottom 10 10%

ADC_Bonfire_Jacket 11 Maji Jacket ya bonfire 1 (inaweza kuwa pato pipe)

ADC_Recu_Input 12 Recuperator pembejeo wazi hewa

ADC_Bonfire_Convection 13 Zaidi ya bonfire (wachache cm kutoka bomba bomba)

(Hutumika kwa Moto Air Distribution na bonfire kwa sasa)

ADC_Recu_Out 14 Recuperator Nje (kwa ajili ya kusambaza nyumba katika hewa wazi)

ADC_Bonfire_Jacket 2 15 Water Jacket ya bonfire 2 (inaweza kuwa pato pipe)

ADC_Heater 16 Ziko kuhusu 1 mita katika hewa baada ya Maji heater (kwa ajili ya kurekebisha heater

joto na umeme cutout njia tatu)

ADC_Internal * 17 ya Ndani Chumba (Je, kuwa na kuchukuliwa kutoka meneja programmerad chumba , kama

sensor si zimeunganishwa ndani ya nchi . Inahitaji Online PC uhusiano na

" eHouse.exe " maombi ya mbio kuendelea)

ADC_Recu_Exhaust 18 Air nimechoka na nyumba (ziko katika hewa vent duct)

VCC (5 V - imetulia) 19 VCC (pato 5 V kutoka kujenga katika kiimarishaji) kwa ajili ya driva Analog

sensorer (Si kuungana)

VCC (5 V - imetulia) 20 VCC (pato 5 V kutoka kujenga katika kiimarishaji) kwa ajili ya driva Analog

sensorer (Si kuungana)





* ADC_Internal Ndani joto la kawaida (katika kesi ya kukosa , hii joto sensor inaweza kusoma kutoka

programmerad sensor kushikamana na yoyote RoomManager , inahitaji kuendelea kufanya kazi ya

eHouse.exe maombi ya PC)

* ADC_External_N Nje Kaskazini joto (katika kesi ya ukosefu , hii joto sensor inaweza kusoma kutoka

programmerad sensor kushikamana na yoyote RoomManager , inahitaji kuendelea kufanya kazi ya

eHouse.exe maombi ya PC)

* ADC_External_S Nje Kusini joto (katika kesi ya ukosefu , hii joto sensor inaweza kusoma kutoka

programmerad sensor kushikamana na yoyote RoomManager , inahitaji kuendelea kufanya kazi ya

eHouse maombi ya PC)





Kontakt J5 - Matokeo ya HeatManager (IDC - 40)


Pato Jina OUT NR Description

NR Pin

Relay J5

Bonfire_Pump 1 3 Bonfire maji pampu uhusiano

Heating_plus 2 4 umeme njia tatu cutout kudhibiti + (kuongeza Temp)

Heating_minus 3 5 umeme njia tatu cutout kudhibiti - (Kupungua Temp)

Boiler_Power 4 6 Geuka wa boiler nguvu ugavi

Fuel_supply_Control_Enable 5 7 Disable usambazaji mafuta gari

Heater_Pump 6 8 Maji heater pampu uhusiano

Fuel_supply_Override 7 9 kuu udhibiti wa mafuta ya gari ugavi

Boiler_Pump 8 10 Boiler pampu ya maji

FAN_HAD 9 11 Moto hewa usambazaji kutoka bonfire (shabiki uhusiano)

FAN_AUX_Recu 10 12 ziada msaidizi mashabiki kwa recuperator (kuongeza ufanisi wa uingizaji hewa)

FAN_Bonfire 11 13 msaidizi Picha kwa bonfire (kama mvuto ukame si wa kutosha)

Bypass_HE_Yes 12 14 Recuperator joto exchanger off (au nafasi bypassed ya servomotor)

Recu_Power_On 13 15 Recuperator nguvu juu ya udhibiti wa moja kwa moja ya recuperator .

Cooler_Heater_Pump 14 16 Maji heater / baridi pampu uhusiano kwa uingizaji hewa kupitia

ardhi joto exchanger .

FAN_GHE 15 17 Auxiliary Picha kwa mtiririko kuongeza hewa kupitia chini exchanger joto .

Boiler_On 16 18 Ili Boiler kudhibiti pembejeo (juu ya mbali /) .

Solar_Pump 17 19 Sola mfumo wa maji ya bomba .

Bypass_HE_No 18 20 Recuperator joto exchanger juu (au bypassed nafasi ya servomotor) .

Servomotor_Recu_GHE 19 21 Air kwa ajili ya uingizaji hewa kuchukuliwa kutoka nchi exchanger joto .

Servomotor_Recu_Deriver 20 22 Air kwa ajili ya uingizaji hewa kuchukuliwa kutoka deriver .

WENT_Fan_GHE 21 23 Auxiliary Picha kwa exchanger joto ardhini 2 .



Kontakt J3 - Matokeo sasa HeatManager (IDC - 16)


Pato J3 Pin Description

Recu Kiwango 1 1 (mshale juu ya tundu) Recuperator ngazi ya 1 ya moja kwa moja kudhibiti **

Recu Ngazi ya 2 2 Recuperator ngazi ya 2 ya moja kwa moja kudhibiti **

Alarm Jua LED * 3 Alarm overheating nishati ya jua (LED)

Recu Kiwango 3 4 Recuperator ngazi 3 moja kwa moja kudhibiti **

Nyekundu LED * 5 Bonfire sasa (Red LED + anode)

Recu Joto Exchanger 6 Recuperator joto Exchanger moja kwa moja kudhibiti REGO **

Kijani * 7 Bonfire sasa (Green LED + anode)

Recu ILIYO Bis 8 Recuperator Power On Udhibiti wa moja kwa moja **

Njano * 9 Bonfire sasa (Yellow LED + anode)

NC 10 N / A

Ardhi - GND (0V) 11 Ground Cathodes ( - ) Kwa ajili ya LED

Ardhi - GND (0V) 12 Ground Cathodes ( - ) Kwa ajili ya LED

Boiler Alarm * 13 Boiler overheating (LED + anode)

5 V (Built - katika pato kiimarishaji)

14 Je, si kuungana

Bluu 15 joto ngazi kwa buffer ya maji moto (Blue + LED)

Kiwango cha Kufuta 16 Firmware kufuta si kuungana

Buzzer - Alarm buzzer 5V badala ya nje IR transmitter na 5 V (VCC)


* Matokeo ya uwezo na gari moja tu LED . Anode (+) lazima kushikamana pato , Cathode ( - ) Na GND ya HeatManager (0V - pini 12 au 11 kontakt J3)

** Uhusiano na matokeo hayo inahitaji madereva ULN2003 na RELAYS ,




Connectors ya RoomManager , Rev ExternalManager . 6 .


Digital pembejeo - kontakt IDC - 16 kiume (J3)


Wote pato digital ni kushikamana na kuvuta UP resistors (10k) na VCC (5 V) Pembejeo ni kushikamana na processor via resistor Serial 330 OM kwa ulinzi . Kawaida hali ya pembejeo ni mantiki 1 na lazima mfupi - mzunguko kupitia kubadili GND na mabadiliko ya hali ya 0 mantiki .

Sensorer au swichi siri NC (kawaida kushikamana) wanapaswa kushikamana na pembejeo X , Com siri (ya kawaida) na GND .


PIN J3 PRC Description

1 INT2 int 2 (digital pembejeo) (mraba pedi juu ya TAKURU)

2 INT3 int 3 (digital pembejeo)

3 INT1 int 1 (digital pembejeo)

4 INT4 int 4 (digital pembejeo)

5 IN1 katika 1 (digital pembejeo)

6 INT5 int 5 (digital pembejeo)

7 IN2 katika 2 (digital pembejeo)

8 INT6 int 6 (digital pembejeo)

9 IN3 katika 3 (digital pembejeo)

10 INT7 int 7 (digital pembejeo)

11 GND Ground GND (0V)

12 GND Ground GND (0V)

13 IN4 katika 4 (digital pembejeo)

14 VCC Ndani kiimarishaji pato (5 V) . Je, matumizi ya

15 IN5 katika 5 (digital pembejeo)

16 FL_CLR Wazi firmware (kazi 0V) . Don ' t kuungana


Analog pembejeo - kontakt IDC - 20 kiume (J4) .


Wote pembejeo Analog ni kushikamana via Ng'oa - Juu resistors 4k7 na 5 V . Pembejeo ni kushikamana na processor via OM Serial resistor 330 kwa ajili ya ulinzi . Unconnected pembejeo serikali ni 5 V .

Wote pembejeo kipimo Analog voltage ngazi ya kati ya kila pembejeo na Channel GND ya mtawala .

LM335 sensorer joto lazima kushikamana kati GND na pembejeo . Tatu PIN (Kurekebisha) zinaweza kukatwa .

PIN J4 PRC Description

1 GND Ground - GND (Pamoja sensorer joto , na mwanga kiwango)

2 GND Ground - GND (Pamoja sensorer joto , na mwanga kiwango)

3 AN1 Analog Pembejeo 1 < 0 , VCC) (Je, matumizi ya kama juu ya - bodi sensor imewekwa

- picha transistor)

4 AN2 Analog Pembejeo 2 < 0 , VCC) (Je, matumizi ya kama juu ya - bodi sensor imewekwa - LM335)

5 AN3 Analog Pembejeo 3 < 0 , VCC) (Je, matumizi ya kama juu ya - bodi sensor imewekwa - LM335)

6 AN4 Analog Pembejeo 4 < 0 , VCC)

7 AN5 Analog Pembejeo 5 < 0 , VCC)

8 AN6 Analog Pembejeo 6 < 0 , VCC)

9 AN7 Analog Pembejeo 7 < 0 , VCC)

10 AN8 Analog Pembejeo 8 < 0 , VCC)

11 AN9 Analog Pembejeo 9 < 0 , VCC) Ni kwa ajili ya HeatManager , Don't kuungana vinginevyo

12 AN10 Analog Pembejeo 10 < 0 , VCC) Ni kwa ajili ya HeatManager , Don't kuungana vinginevyo

13 AN11 Analog Pembejeo 11 < 0 , VCC) Ni kwa ajili ya HeatManager , Don't kuungana vinginevyo

14 AN12 Analog Pembejeo 12 < 0 , VCC) Ni kwa ajili ya HeatManager , Don't kuungana vinginevyo

15 AN13 Analog Pembejeo 13 < 0 , VCC) Ni kwa ajili ya HeatManager , Don't kuungana vinginevyo

16 AN14 Analog Pembejeo 14 < 0 , VCC) Ni kwa ajili ya HeatManager , Don't kuungana vinginevyo

17 AN15 Analog Pembejeo 15 < 0 , VCC) Ni kwa ajili ya HeatManager , Don't kuungana vinginevyo

18 AN16 Analog Pembejeo 16 < 0 , VCC) Ni kwa ajili ya HeatManager , Don't kuungana vinginevyo

19 VCC (5 V ndani kiimarishaji pato) si kuungana

20 VCC (5 V ndani kiimarishaji pato) si kuungana


Digital Matokeo - kontakt IDC - 40 kiume (J5)


Wote matokeo ya controllers OUTxx ni Open Collector (OC) ya aina , max sasa 100mA , max voltage 20V , hii maadili ni ya kutosha kwa ajili ya moja kwa moja gari RELAYS kati ya uzalishaji na usambazaji wa nguvu chanya .

NR Signal RM Relay Meneja Nje

1 , 2 VCCDRV Relay ya umeme kutoka mbunge (5 V huru kutoka RoomManager)

kwa madereva ulinzi . Si kuungana na 5 V juu ya Mdhibiti

3 OUT1 1 Roller 1 Open

4 OUT2 2 Roller 1 Close

5 OUT3 3 Roller 2 Open

6 OUT4 4 Roller 2 Close

7 OUT5 5 Roller 3 Open

8 OUT6 6 Roller 3 Close

9 OUT7 7 Roller 4 Open

10 OUT8 8 Roller 4 Close

11 OUT9 9 Roller 5 Open

12 OUT10 10 Roller 5 Close

13 OUT11 11 Roller 6 Open

14 OUT12 12 Roller 6 Close

15 OUT13 13 Roller 7 Open

16 OUT14 14 Roller 7 Close

17 OUT15 15 Roller 8 Open

18 OUT16 16 Roller 8 Close

19 OUT17 17 Nje Open Gate

20 OUT18 18 Nje Gate Close

21 OUT19 19 Garage Door Open

22 OUT20 20 Garage Door Close

23 21 OUT21 Kuu Door Roller (Open)

24 22 OUT22 Kuu Door Roller (Close)

25 OUT23 23 Gate Open

26 OUT24 24 Digital Output 1

27 OUT25 25 Roller 9 Open RM - Ltd (baadaye kutumia)

28 OUT26 26 Roller 9 Close RM - Ltd (baadaye kutumia)

29 OUT27 27 Roller 10 Open RM - Ltd (baadaye kutumia)

30 OUT28 28 Roller 10 Close RM - Ltd (baadaye kutumia)

31 OUT29 29 Roller 11 Open RM - Ltd (baadaye kutumia)

32 OUT30 30 Roller 11 Close RM - Ltd (baadaye kutumia)

33 OUT31 31 Digital Output 2

34 OUT32 32 Alarm taa , RM - Ltd (baadaye kutumia)

35 OUT33 33 Alarm Pembe , RM - Ltd (baadaye kutumia)

36 OUT34 34 (diode 2)

37 OUT35 35 (diode 1)

38 CPP3 (PWM pato) kwa nguvu dimmer dereva 3

39 CPP2 (PWM pato) kwa nguvu dimmer dereva 2

40 CPP1 (PWM pato) kwa nguvu dimmer dereva 1



2 pini connectors (Joto sensorer T1 , T2) J7 , J8


4 kontakt pini (Power) J2


1 Pato 5 V (Internal kiimarishaji RM , EM , HM) , si kuungana na 5 V nguvu basi wala

VCCDRV (Juu ya IDC - 40 siri soketi) .

2 GND (0V)

3 GND

4 Power ugavi 12 V (pembejeo kwa ajili ya 5 kiimarishaji V) RM , EM , HM .


Kontakt RJ - 45 eHouse 1 Data Bus (J1)


1 GND (0V)

2 GND

3 VCC (5 V) Ndani ya pato kiimarishaji lazima disconnected .

4 VCC (5 V) Ndani ya pato kiimarishaji lazima disconnected .

5 TX + Transmitter tofauti pato chanya (+) eHouse 1 RS basi data - 485 .

6 TX - Transmitter tofauti pato hasi ( - ) EHouse 1 data bus RS - 485 .

7 RX + kupokea tofauti mchango chanya (+) eHouse 1 RS basi data - 485 .

8 RX - Receiver tofauti pembejeo hasi ( - ) EHouse 1 data bus RS - 485 .



Kontakt 10pin kiume SIP - 10 RS232 ttl - UART 2 (J6)


1 GND (0V)

2 VCC (5 V) ndani kiimarishaji pato HM , RM , EM kwa driva ugani modules

(Bluetooth , Mifare kadi msomaji) ,

3 RX2 Kupokea mchango UART 2 (RS232 ttl) kwa ajili ya uhusiano na TX pato juu Bluetooth ,

InputExtender , Recuperator , Kadi Mifare Reader) ,

4 TX2 Transmitter pato UART 2 (RS232 ttl) kwa ajili ya uhusiano na pembejeo RX juu ya Bluetooth ,

InputExtender , Recuperator , Kadi Mifare Reader) ,

5 RX Kupokea mchango UART 1 (RS232 ttl) si kuungana (kutumiwa na RS - 485 dereva) ,

6 TX Transmitter pato UART 1 (RS232 ttl) si kuungana (kutumiwa na RS - 485 dereva) ,

7 RX2IN kupokea pembejeo UART 2 (RS232C standard) ikiwa imewekwa MAX3232 badala ya MAX3086 ,

8 TX2OUT Transmitter pato UART 2 (RS232C standard) ikiwa imewekwa MAX3232 badala ya MAX3086 ,

9 RX1IN kupokea Pembejeo UART 1 (RS232C standard) ikiwa imewekwa MAX3232 badala ya MAX3086 ,

10 TX1OUT Transmitter pato UART 1 (RS232C standard) ikiwa imewekwa MAX3232 badala ya MAX3086 .



3 . 4 . InputExtender I / II (Usalama Mfumo)


InputExtenders ni sehemu ya mfumo wa usalama eHouse pamoja na ExternalManager . Kila InputExtender mimi inaruhusu kuunganisha hadi sensorer alarm 28 . Kujiondoa maoni kutoka nchi kuzalisha alarm au onyo kulingana na tafsiri ya sasa ya eneo na kama ishara ya chombo hicho lazima checked au . InputExtender ina 1 Analog pembejeo ambayo wanaweza kufanya kazi kama Tamper (hujuma) kwa kutambua mabadiliko ya ghafla ya voltage juu yake .


ExternalManager wanaweza kushirikiana na max . 3 InputExtenders . Maximal idadi ya maeneo ambayo inaweza defined ni 25 iliyopita pamoja kwa kila InputExtenders .

Kila InputExtender ' s pembejeo (Sensor) jina pekee inaweza kupewa katika eHouse.exe maombi .

Kuna pia ni uwezekano kwa majina ya viumbe Intuitive ya kanda ambayo inatoa urahisi wa habari katika mfumo wa kumbukumbu na taswira na akustisk signalization wa matukio .


InputExtender II (Bis) ni kupishana InputExtender I , kuruhusu moja kwa moja na moja kwa moja kurudia kwenye vifaa katika mwitikio wa Activation sensor . Mask ni mmoja mmoja aliumba kwa kila sensor na kila eneo .

InputExtender Bis inaruhusu uhusiano wa sensorer alarm 14 . Kujiondoa maoni kutoka ardhi kuzalisha alarm au onyo kwa kutegemea eneo sasa ufafanuzi na kama ishara ya chombo hicho lazima checked au . InputExtender II 1 Analog pembejeo ambayo wanaweza kufanya kazi kama tamper (Hujuma) kwa kutambua mabadiliko ya ghafla ya voltage juu yake .

Kuna pia ni matokeo ya moja kwa moja 14 kwa ajili ya pembejeo . Kila pato Activation ni kufanya kama ni kuwezeshwa kwa eneo sasa na sensor Activation alikuwa wamekutana Activation muda inategemea sensor Activation . Kila mask pato ni kuweka mmoja mmoja kwa kila eneo .

InputExtenders ina mapema Onyo pato - ambayo ni mara moja ulioamilishwa katika kesi ya kazi sensor (kufuatiliwa katika eneo sasa) , na ni deactivated 10sec baada ya sensorer deactivated .


Alarm pembe , taa ni aktiverat baada ya dakika 1 kutoka kubadilisha eneo , ambayo inatoa uwezekano wa kuondoa chanzo cha alarm kabla ya kutuma ishara ya ufuatiliaji au usalama wa shirika .


eHouse maombi baada ya kupokea ishara kutuma SMS notification na mbili defined makundi:


eHouse watendaji - ambao ni taarifa juu ya kila mabadiliko ya eneo na usalama sensorer ukiukaji ,

taarifa watumiaji - ambao ni taarifa juu ya usalama na ukiukwaji sensorer alarm deactivation kwa watumiaji wa mamlaka (watendaji , elektroniki RF funguo , PDA , paneler , au kutoka maombi eHouse) . kikundi hiki kinaweza simu namba ya majirani , polisi , usalama wa shirika , nk .


schematic12


Connectors InputExtender IE1 / IE2


Connectors A1 - A28 ( A14 * ) (RJ - 12 Alarm Sensorer Connections)


PIN Kazi Description

1 . 12V Power kwa alarm sensor 12V

2 . 0V Ground GND ya Alarm Sensor

3 . Sabotage1 vya NC (kawaida kushikamana) sabotage kubadili (kama si kutumika kufupisha na Sabotage2 (PIN 4)

4 . Sabotage2 vya Com (Common) sabotage kubadili (kama si kutumiwa kufupisha na Sabotage1 (PIN 3)

5 . 0V GND (Ground) - Kuungana vya KOM (Common) relay ya Alarm Sensor

6 . IN1 - 28 ( 14 * ) Pato la Sensor - Kuungana vya NC (kawaida Connected) relay ya Alarm Sensor . Mawasiliano lazima pekee kutoka voltage yoyote , katika kesi nyingine kuna ni mbaya hatari ya mzunguko uharibifu .


Katika kesi ya matatizo na kutafuta siri 1 , 12V voltage lazima kupimwa na multimeter .


* Kwa InputExtender Bis (IE2)


Kontakt SensIn (IDC - 40 Global kontakt kwa wote ufungaji sensorer - badala ya A1 - A28)


PIN Kazi Description

1 . 0V GND (Ground) Nguvu ya Sensorer Usalama

2 . 0V GND (Ground) Nguvu ya Sensorer Usalama

3 . 0V GND (Ground) Nguvu ya Sensorer Usalama

4 . 0V GND (Ground) Nguvu ya Sensorer Usalama

5 . Input hujuma kwa serially kushikamana switches hujuma katika alarm Sensorer katika hali ya kawaida ni lazima kawaida Ilifungwa . Upande mwingine ya switches Sabotage ni kushikamana na uhusiano tamper

Kama si kutumika kwanza safu ya tamper lazima kufupisha na jumper .

6 . IN1 Pato kutoka Alarm Sensor - NC (kawaida Ilifungwa) mawasiliano ya sensor relay au kubadili

7 . IN2 Pato kutoka Alarm Sensor - NC (kawaida Ilifungwa) mawasiliano ya sensor relay au kubadili

8 . IN3 Pato kutoka Alarm Sensor - NC (kawaida Ilifungwa) mawasiliano ya sensor relay au kubadili

9 . IN4 Pato kutoka Alarm Sensor - NC (kawaida Ilifungwa) mawasiliano ya sensor relay au kubadili

10 . IN5 Pato kutoka Alarm Sensor - NC (kawaida Ilifungwa) mawasiliano ya sensor relay au kubadili

11 . IN6 Pato kutoka Alarm Sensor - NC (kawaida Ilifungwa) mawasiliano ya sensor relay au kubadili

12 . IN7 Pato kutoka Alarm Sensor - NC (kawaida Ilifungwa) mawasiliano ya sensor relay au kubadili

13 . IN8 Pato kutoka Alarm Sensor - NC (kawaida Ilifungwa) mawasiliano ya sensor relay au kubadili

14 . IN9 Pato kutoka Alarm Sensor - NC (kawaida Ilifungwa) mawasiliano ya sensor relay au kubadili

15 . IN10 Pato kutoka Alarm Sensor - NC (kawaida Ilifungwa) mawasiliano ya sensor relay au kubadili

16 . IN11 Pato kutoka Alarm Sensor - NC (kawaida Ilifungwa) mawasiliano ya sensor relay au kubadili

17 . IN12 Pato kutoka Alarm Sensor - NC (kawaida Ilifungwa) mawasiliano ya sensor relay au kubadili

18 . IN13 Pato kutoka Alarm Sensor - NC (kawaida Ilifungwa) mawasiliano ya sensor relay au kubadili

19 . IN14 Pato kutoka Alarm Sensor - NC (kawaida Ilifungwa) mawasiliano ya sensor relay au kubadili

20 . IN15 Pato kutoka Alarm Sensor - NC (kawaida Ilifungwa) mawasiliano ya sensor relay au kubadili
( si kuungana * kwa IE2 - moduli vinaweza kuharibika )

21 . IN16 Pato kutoka Alarm Sensor - NC (kawaida Ilifungwa) mawasiliano ya sensor relay au kubadili
( si kuungana * kwa IE2 - moduli vinaweza kuharibika )

22 . IN17 Pato kutoka Alarm Sensor - NC (kawaida Ilifungwa) mawasiliano ya sensor relay au kubadili
( si kuungana * kwa IE2 - moduli vinaweza kuharibika )

23 . IN18 Pato kutoka Alarm Sensor - NC (kawaida Ilifungwa) mawasiliano ya sensor relay au kubadili
( si kuungana * kwa IE2 - moduli vinaweza kuharibika )

24 . IN19 Pato kutoka Alarm Sensor - NC (kawaida Ilifungwa) mawasiliano ya sensor relay au kubadili
( si kuungana * kwa IE2 - moduli vinaweza kuharibika )

25 . IN20 Pato kutoka Alarm Sensor - NC (kawaida Ilifungwa) mawasiliano ya sensor relay au kubadili
( si kuungana * kwa IE2 - moduli vinaweza kuharibika )

26 . IN21 Pato kutoka Alarm Sensor - NC (kawaida Ilifungwa) mawasiliano ya sensor relay au kubadili
( si kuungana * kwa IE2 - moduli vinaweza kuharibika )

27 . IN22 Pato kutoka Alarm Sensor - NC (kawaida Ilifungwa) mawasiliano ya sensor relay au kubadili
( si kuungana * kwa IE2 - moduli vinaweza kuharibika )

28 . IN23 Pato kutoka Alarm Sensor - NC (kawaida Ilifungwa) mawasiliano ya sensor relay au kubadili
( si kuungana * kwa IE2 - moduli vinaweza kuharibika )

29 . IN24 Pato kutoka Alarm Sensor - NC (kawaida Ilifungwa) mawasiliano ya sensor relay au kubadili
( si kuungana * kwa IE2 - moduli vinaweza kuharibika )

30 . IN25 Pato kutoka Alarm Sensor - NC (kawaida Ilifungwa) mawasiliano ya sensor relay au kubadili
( si kuungana * kwa IE2 - moduli vinaweza kuharibika )

31 . IN26 Pato kutoka Alarm Sensor - NC (kawaida Ilifungwa) mawasiliano ya sensor relay au kubadili
( si kuungana * kwa IE2 - moduli vinaweza kuharibika )

32 . IN27 Pato kutoka Alarm Sensor - NC (kawaida Ilifungwa) mawasiliano ya sensor relay au kubadili
( si kuungana * kwa IE2 - moduli vinaweza kuharibika )

33 . IN28 Pato kutoka Alarm Sensor - NC (kawaida Ilifungwa) mawasiliano ya sensor relay au kubadili

( kufanya si kuungana * kwa IE2 - moduli vinaweza kuharibika )

34 . N / C N / A

35 . N / C N / A

36 . N / C N / A

37 . 12V 12 V Power ugavi kwa Sensorer Alarm ( Si kuungana na pembejeo yoyote , inaweza kuharibu modules )

38 . 12V 12 V Power ugavi kwa Sensorer Alarm ( Si kuungana na pembejeo yoyote , inaweza kuharibu modules )

39 . 12V 12 V Power ugavi kwa Sensorer Alarm ( Si kuungana na pembejeo yoyote , inaweza kuharibu modules )

40 . 12V 12 V Power ugavi kwa Sensorer Alarm ( Si kuungana na pembejeo yoyote , inaweza kuharibu modules )




* Kwa InputExtender Bis (IE2)



Kontakt Tamper (Sabotage Count IDC - 58 msumari wa kiume) - NR ya sensorer kwa ajili ya kuangalia sabotage (lazima kuwa imewekwa hatimaye kutoka A1 na A28)

NR Description safu (jumper) Idadi ya usalama sensorer kushikamana na matako A1 - 28

1 0 Alarm Sensorer / Hakuna ya kuangalia

2 1

3 2

4 3

5 4

6 5

7 6

8 7

9 8

10 9

11 10

12 11

13 12

14 13

15 14

16 15

17 16

18 17

19 18

20 19

21 20

22 21

23 22

24 23

25 24

26 25

27 26

28 27

29 28

Connectors tu kwa ajili ya InputExtender II Bis (IE2)


Kontakt INP2 (IDC - 16 Global uhusiano wa sensorer alarm - badala ya A1 - A14)

(Au badala ya pembejeo kontakt kwa IE)


PIN Kazi Description

1 . 0V GND (Ground) Alarm Sensorer

2 . Hujuma Pembejeo kwa ajili ya matokeo serially kushikamana hujuma ya alarm sensorer . Ni lazima kawaida C.
Hujuma Pembejeo kwa ajili ya serially kushikamana switches hujuma katika Sensorer kelele katika kawaida hali

ni lazima kawaida Ilifungwa . upande mwingine wa switches Sabotage ni kushikamana tamper uhusiano . Kama si kutumiwa safu ya kwanza ya tamper lazima kuwa kufupisha na jumper .

3 . IN1 Pato kutoka Alarm Sensor - NC (kawaida Ilifungwa) mawasiliano ya sensor relay au kubadili

4 . IN2 Pato kutoka Alarm Sensor - NC (kawaida Ilifungwa) mawasiliano ya sensor relay au kubadili

5 . IN3 Pato kutoka Alarm Sensor - NC (kawaida Ilifungwa) mawasiliano ya sensor relay au kubadili

6 . IN4 Pato kutoka Alarm Sensor - NC (kawaida Ilifungwa) mawasiliano ya sensor relay au kubadili

7 . IN5 Pato kutoka Alarm Sensor - NC (kawaida Ilifungwa) mawasiliano ya sensor relay au kubadili

8 . IN6 Pato kutoka Alarm Sensor - NC (kawaida Ilifungwa) mawasiliano ya sensor relay au kubadili

9 . IN7 Pato kutoka Alarm Sensor - NC (kawaida Ilifungwa) mawasiliano ya sensor relay au kubadili

10 . IN8 Pato kutoka Alarm Sensor - NC (kawaida Ilifungwa) mawasiliano ya sensor relay au kubadili

11 . IN9 Pato kutoka Alarm Sensor - NC (kawaida Ilifungwa) mawasiliano ya sensor relay au kubadili

12 . IN10 Pato kutoka Alarm Sensor - NC (kawaida Ilifungwa) mawasiliano ya sensor relay au kubadili

13 . IN11 Pato kutoka Alarm Sensor - NC (kawaida Ilifungwa) mawasiliano ya sensor relay au kubadili

14 . IN12 Pato kutoka Alarm Sensor - NC (kawaida Ilifungwa) mawasiliano ya sensor relay au kubadili

15 . IN13 Pato kutoka Alarm Sensor - NC (kawaida Ilifungwa) mawasiliano ya sensor relay au kubadili

16 . IN14 Pato kutoka Alarm Sensor - NC (kawaida Ilifungwa) mawasiliano ya sensor relay au kubadili


Kontakt (Songea Kati) (IDC - 16 uhusiano kwa kudhibiti matokeo ya Expander EX)

(Flat cable 16 siri , 1 na uhusiano 1) .

Kwa taarifa tu - inverting uhusiano inaweza kusababisha uharibifu wa kudumu wa modules na nguvu vifaa .


PIN Kazi Description

1 . VCCDRV Power Ugavi kwa RELAYS (5 V) si UPS ' ed

2 . VCCDRV Power Ugavi kwa RELAYS (5 V) si UPS ' ed

3 . OUT1 Output kudhibitiwa na pembejeo IN1 (**)

4 . OUT2 Output kudhibitiwa na pembejeo IN2 (**)

5 . OUT3 Output kudhibitiwa na pembejeo IN3 (**)

6 . OUT4 Output kudhibitiwa na pembejeo IN4 (**)

7 . OUT5 Output kudhibitiwa na pembejeo IN5 (**)

8 . OUT6 Output kudhibitiwa na pembejeo IN6 (**)

9 . OUT7 Output kudhibitiwa na pembejeo IN7 (**)

10 . OUT8 Output kudhibitiwa na pembejeo IN8 (**)

11 . OUT9 Output kudhibitiwa na pembejeo IN9 (**)

12 . OUT10 Output kudhibitiwa na pembejeo IN10 (**)

13 . OUT11 Output kudhibitiwa na pembejeo IN11 (**)

14 . OUT12 Output kudhibitiwa na pembejeo IN12 (**)

15 . OUT13 Output kudhibitiwa na pembejeo IN13 (**)

16 . OUT14 Output kudhibitiwa na pembejeo IN14 (**)


(**) Pato humenyuka moja kwa moja kwenye Activation ya alarm sensor

1 Mstari connectors

PIN 1 ina pedi mraba juu ya PCB .

2 Mstari connectors

PIN 1 ina pedi mraba juu ya PCB na mshale juu ya bima .


1 2

3 4

5 6

7 8

.

.

39 40


Sambamba uhusiano wa sensorer alarm kwa zaidi ya moja mifumo ya usalama .


- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Alarm Sensor | (*) Shotky diodes low voltage ngazi .

| *

| - - - - - - | < - - - - - - - - - Na kwanza mfumo wa usalama

| | *

| o - - - - - | < - - - - - - - - - - Na mfumo wa usalama ijayo

| | *

Pato wa NC relay | - - - - - - - - - o - - - - - | < - - - - - - - - - - Na sensor pembejeo mfumo wa InputExtender eHouse

kwa alarm notification |

KOM | - - - - - - - - o - - - - - - - - - - - - - - - - - - Kawaida GND ya mifumo yote (OV)

| GND

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Hujuma matokeo ya lazima kushikamana na mfumo mmoja tu bila ya mabadiliko yoyote

Kutumia Diodes kwa ajili ya kujitenga wa mifumo ya usalama nyingi husababisha kupungua margin ya makosa na InputExtender inaweza kuzalisha alarm bandia katika kesi ya nguvu sana mvurugano (radi , karibu hatiani kwa Antena GSM Mwenye nguvu signaler) .



3 . 5 . Expander (EX) .

Moduli kufanya kazi hautokani mantiki , huonyesha tu (5 V) UPS kwa ajili ya eHouse mfumo wa usalama (IE) na RS232 - RS485 Converter . Nguvu ni kuchukuliwa kutoka 12 V UPS . Moduli inawezesha uhusiano rahisi wa mfumo mzima wa usalama:

Expander ina RELAYS kwa byte moja kwa moja kwenye Alarm Pembe , Mwanga , Mapema Onyo signal , Pato 1 ya ExternalManager , Pato 2 ya ExternalManager .

Tu vifaa hutolewa kwa nguvu 15V yanaweza kushikamana na mawasiliano ya relay . Uhusiano wa vifaa 230V kunaweza kusababisha uharibifu wa kudumu wa eHouse wote mfumo .


3 . 5 . 1 . Expander matokeo na connectors kwa IE / IE2


Kontakt (RELAYS IDC - 40 siri) kwa ajili ya kuunganisha Relay Module na ExternalManager


NR Signal RM Relay Meneja Nje

1 , 2 VCCDRV ya umeme kutoka mbunge (5 V Independent kutoka RoomManager)

kwa madereva ulinzi .

3 OUT1 1 Roller 1 wazi

4 OUT2 2 Roller 1 karibu

5 OUT3 3 Roller 2 wazi

6 OUT4 4 Roller 2 karibu

7 OUT5 5 Roller 3 wazi

8 OUT6 6 Roller 3 karibu

9 OUT7 7 Roller 4 wazi

10 OUT8 8 Roller 4 karibu

11 OUT9 9 Roller 5 wazi

12 OUT10 10 Roller 5 karibu

13 OUT11 11 Roller 6 wazi

14 OUT12 12 Roller 6 karibu

15 OUT13 13 Roller 7 wazi

16 OUT14 14 Roller 7 karibu

17 OUT15 15 Roller 8 wazi

18 OUT16 16 Roller 8 karibu

19 OUT17 17 Nje mlango wazi

20 OUT18 18 Nje lango karibu

21 OUT19 19 Garage mlango wazi

22 OUT20 20 Garage mlango karibu

23 21 OUT21 Kuu mlango roller (wazi)

24 22 OUT22 Kuu mlango roller (karibu)

25 OUT23 23 Mlango wazi

26 OUT24 24 Digital pato 1

27 OUT25 25 Roller 9 wazi RM - Ltd (baadaye kutumia)

28 OUT26 26 Roller 9 karibu RM - Ltd (baadaye kutumia)

29 OUT27 27 Roller 10 wazi RM - Ltd (baadaye kutumia)

30 OUT28 28 Roller 10 karibu RM - Ltd (baadaye kutumia)

31 OUT29 29 Roller 11 wazi RM - Ltd (baadaye kutumia)

32 OUT30 30 Roller 11 karibu RM - Ltd (baadaye kutumia)

33 OUT31 31 Digital pato 2

34 OUT32 32 Alarm taa RM - Ltd (baadaye kutumia)

35 OUT33 33 Alarm pembe RM - Ltd (baadaye kutumia)

36 OUT34 34 (diode 2)

37 OUT35 35 (diode 1)

38 CPP3 (PWM pato) kwa nguvu dimmer dereva 3

39 CPP2 (PWM pato) kwa nguvu dimmer dereva 2

40 CPP1 (PWM pato) kwa nguvu dimmer dereva 1



Kontakt kwa ajili ya kuendesha relay moduli na matokeo ya InputExtenders II (Bis) (Movement RELAYS , IDC - 40 PIN)


NR Signal Relay Description

1 , 2 VCCDRV ya umeme kutoka mbunge (5 V Independent kutoka RoomManager)

kwa madereva ulinzi . Si kuungana na 5 V juu ya uzalishaji wa mtawala

3 Kuondoka OUT1 1 pato 1 ya NR IE2 1

4 Kuondoka OUT2 2 pato 2 ya NR IE2 1

5 Kuondoka OUT3 3 pato 3 ya NR IE2 1

6 Kuondoka OUT4 4 pato 4 ya NR IE2 1

7 Kuondoka OUT5 5 pato 5 ya NR IE2 1

8 Kuondoka OUT6 6 pato 6 ya NR IE2 1

9 Kuondoka OUT7 7 pato 7 ya NR IE2 1

10 Kuondoka OUT8 8 pato 8 ya NR IE2 1

11 Kuondoka OUT9 9 pato 9 ya NR IE2 1

12 Kuondoka OUT10 10 ya pato 10 ya NR IE2 1

13 Kuondoka OUT11 11 ya pato 11 ya NR IE2 1

14 Kuondoka OUT12 12 ya pato 12 ya NR IE2 1

15 Kuondoka OUT13 13 ya pato 13 ya NR IE2 1

16 Kuondoka OUT14 14 ya pato 14 ya NR IE2 1

17 Kuondoka OUT15 15 ya pato 1 ya NR IE2 2

18 Kuondoka OUT16 16 ya pato 2 ya NR IE2 2

19 Kuondoka OUT17 17 ya pato 3 ya NR IE2 2

20 Kuondoka OUT18 18 ya pato 4 ya NR IE2 2

21 Kuondoka OUT19 19 ya pato 5 ya NR IE2 2

22 Kuondoka OUT20 20 ya pato 6 ya NR IE2 2

23 Kuondoka OUT21 21 ya pato 7 ya NR IE2 2

24 Kuondoka OUT22 22 ya pato 8 ya NR IE2 2

25 Kuondoka OUT23 23 ya pato 9 ya NR IE2 2

26 Kuondoka OUT24 24 ya pato 10 ya NR IE2 2

27 Kuondoka OUT25 25 ya pato 11 ya NR IE2 2

28 Kuondoka OUT26 26 ya pato 12 ya NR IE2 2

29 Kuondoka OUT27 27 ya pato 13 ya NR IE2 2

30 Kuondoka OUT28 28 ya pato 14 ya NR IE2 2

31 Kuondoka OUT29 29 ya pato 1 ya NR IE2 3

32 Kuondoka OUT30 30 ya pato 2 ya NR IE2 3

33 Kuondoka OUT31 31 ya pato 3 ya NR IE2 3

34 Kuondoka OUT32 32 ya pato 4 ya NR IE2 3

35 Kuondoka OUT33 33 ya pato 5 ya NR IE2 3

36 Kuondoka OUT34 34 ya pato 6 ya NR IE2 3

37 Kuondoka OUT35 35 ya pato 7 ya NR IE2 3



Connectors IEx1 , IEx2 , IEx3 (IDC - 20 Pin) InputExtenders uhusiano na Expander (Flat cable 20 siri , 1 to 1) .

Kwa taarifa tu - inverting uhusiano inaweza kusababisha uharibifu wa kudumu wa modules na nguvu vifaa .


PIN Kazi Description

1 VCCDRV Power kwa RELAYS (5 V) si UPS

2 VCCDRV Power kwa RELAYS (5 V) si UPS

3 VCC Power kutoka kiimarishaji ndani (5 V) kutoka 12 V (UPS)

4 VCC Power kutoka kiimarishaji ndani (5 V) kutoka 12 V (UPS)

5 12V Power ugavi 12 V (UPS) kwa ajili ya usalama sensorer

6 12V Power ugavi 12 V (UPS) kwa ajili ya usalama sensorer

7 0V GND (Ardhi)

8 0V GND (Ardhi)

9 kengele ya ziada alarm pembe IE / IE2

10 MWANGA ziada alarm mwanga IE / IE2

11 RX UART - RX kushikamana na EM

12 TX UART - TX kushikamana na EM

13 TX + RS485 - kuwepo kwa kujenga katika MAX3086 dereva (maambukizi +)

14 TX - RS485 - kuwepo kwa kujenga katika dereva MAX3086 (maambukizi - )

15 RX - RS485 - kuwepo kwa kujenga katika dereva MAX3086 (mapokezi - )

16 RX + RS485 - kuwepo kwa kujenga katika MAX3086 dereva (mapokezi +)

17 0V GND (Ardhi)

18 0V GND (Ardhi)

19 VCCDRV Power kwa RELAYS (5 V) si UPS

20 VCCDRV Power kwa RELAYS (5 V) si UPS


Kontakt RS485 - (RJ - 45 hiari kwa RS imewekwa - 485 dereva)

Kwa taarifa tu - inverting uhusiano inaweza kusababisha uharibifu wa kudumu wa modules na nguvu vifaa .

PIN Kazi Description

1 . 0V GND (Ardhi)

2 . 0V GND (Ardhi)

3 . NC N / A

4 . NC N / A

5 . TX + RS485 - kuwepo kwa kujenga katika MAX3086 dereva (maambukizi +)

6 . TX - RS485 - kuwepo kwa kujenga katika dereva MAX3086 (maambukizi - )

7 . RX - RS485 - kuwepo kwa kujenga katika dereva MAX3086 (mapokezi - )

8 . RX + RS485 - kuwepo kwa kujenga katika dereva MAX3086 (mapokezi - )



Connectors (Songea 1 , 2 , 3) (IDC - 16 uhusiano wa matokeo ya kudhibitiwa na pembejeo za Expander kutoka InputExtender BIS) (Flat cable 16 siri , 1 to 1) .

Kwa taarifa tu - inverting uhusiano inaweza kusababisha uharibifu wa kudumu wa modules na nguvu vifaa .



PIN Kazi Description

1 . VCCDRV Power kwa RELAYS (5 V) si UPS

2 . VCCDRV Power kwa RELAYS (5 V) si UPS

3 . OUT1 Output kudhibitiwa na line IN1 (**)

4 . OUT2 Output kudhibitiwa na line IN2 (**)

5 . OUT3 Output kudhibitiwa na line IN3 (**)

6 . OUT4 Output kudhibitiwa na line IN4 (**)

7 . OUT5 Output kudhibitiwa na line IN5 (**)

8 . OUT6 Output kudhibitiwa na line IN6 (**)

9 . OUT7 Output kudhibitiwa na line IN7 (**)

10 . OUT8 Output kudhibitiwa na line IN8 (**)

11 . OUT9 Output kudhibitiwa na line IN9 (**)

12 . OUT10 Output kudhibitiwa na line IN10 (**)

13 . OUT11 Output kudhibitiwa na line IN11 (**)

14 . OUT12 Output kudhibitiwa na line IN12 (**)

15 . OUT13 Output kudhibitiwa na line IN13 (**)

16 . OUT14 Output kudhibitiwa na line IN14 (**)


(**) Pato humenyuka moja kwa moja kwenye Activation ya alarm sensor


4 PIN Connector kiume (Power Supply) J2


PIN Kazi Description

1 5 V Power Supply 5 V

2 GND GND (Ground) (0V)

3 GND GND (Ardhi) (0V)

4 12 V Nguvu ugavi 12 V (UPS) RM , EM , HM na sensorer driva alarm


10 PIN kontakt SIP - 10 kiume Serial Port - UART (J6)

(Pamoja na vyema 2 mstari kontakt na kuvuka ishara kwa urahisi wa ufungaji 1 to 1 PIN)


PIN Kazi Description

1 GND (0V)

2 NC Hawahusiki

3 TX Kusambaza matokeo ya UART (InputExtender) kwa ajili ya uhusiano ExternalManager

4 RX Kupokea mchango wa UART (InputExtender) kwa ajili ya uhusiano ExternalManager


Kontakt (Ili EM) (IDC - 10 {safu mbili} bandari Serial RS232 ttl - UART) (J6)

(Pamoja na kujenga 2 mstari kontakt bila kuvuka signaler - si kuungana)


PIN Kazi Description

1 GND (0V)

2 NC Si Connected

3 RX Kupokea mchango wa UART (InputExtender) kwa ajili ya uhusiano ExternalManager

4 TX Kusambaza matokeo ya UART (InputExtender) kwa ajili ya uhusiano ExternalManager


1 Mstari connectors

PIN 1 ina squared pedi juu ya PCB .


2 Mstari connectors

PIN 1 ina pedi mraba juu ya PCB na mshale juu ya bima .

1 2

3 4

5 6

7 8

9 10

11 12

13 14

15 16

17 18

19 20

21 22

23 24

.

.

.

39 40


Kujengwa - katika RELAYS:

Kufanya si kuungana voltages mkuu zaidi kuliko 15V

NR Relay Description

1 . (*) ExternalManager (Alarm Mwanga)

2 . ExternalManager (Alarm Pembe)

3 . ExternalManager - Pato 2

4 . InputExtenders Multiplexed (Additional Alarm Mwanga)

5 . InputExtenders Multiplexed (Additional Alarm Pembe)

6 . ExternalManager - Pato 1


(*) Kuhesabu kuanzia connectors nguvu


RELAYS mawasiliano - 3 siri matako , Star .


NR Kazi siri Description

1 . (*) NC kawaida karibu (kufupisha na COM) ,

2 . Common KOM ,

3 . NO kawaida wazi (unconnected na COM) ,


(*) Kuhesabu kuanzia connectors nguvu (kutoka kulia na kushoto) .



3 . 6 . Relay Module .


Relay Moduli inawezesha kubadili moja kwa moja juu ya vifaa / off mtendaji pamoja na kujenga katika RELAYS (na mawasiliano 230V / 10a) . Kufata mzigo unaweza ' t kushikamana kwa mawasiliano ila pampu , mashabiki . Maximal kiasi cha RELAYS imewekwa ni 35 . hesabu ya mwisho inategemea wa aina moduli .


Mtawala Used hesabu ya RELAYS

HeatManager 21

RoomManager 24 - 35

ExternalManager 35

CommManager 35 * 2

InputExtender Bis 14


RELAYS Moduli inawezesha ufungaji rahisi ya data eHouse na mabasi nguvu . Nguvu basi (3 * 2 . 5mm2 cable ya umeme) ni ironed ya moduli kwa juu ya upinzani kuwasiliana na kuwahakikishia kudumu kwa muda mrefu na sahihi kazi ya mfumo . Vinginevyo voltage matone , inaweza kusababisha kikwazo madhubuti ya umeme na thamani ya kutosha kwa kubadili RELAYS hasa baada ya miaka michache ya kazi .

RELAYS Moduli ina soketi 3 RJ - 45 kwa ajili ya kuunganisha vipande jirani Takwimu ya eHouse Bus .

1) ya awali RELAYS Module ,

2) na RM , EM , HM mtawala ,

3) kwa karibu RELAYS Module .


230V cables lazima ironed moja kwa moja na TAKURU (kwa mawasiliano ya RELAYS) katika ili kuwahakikishia kudumu kwa muda mrefu na sahihi kazi ya mfumo , huru kutoka sparkling , mziki upinzani wa mawasiliano . Katika kesi ya Star connections sparkling na kubwa vya upinzani inaweza kusababisha kuungua njia ya moduli , shortcuts na uharibifu wa kudumu mfumo . Wote cables ironed lazima 50cm vipuri na kuwezesha huduma rahisi ya moduli na kubadilisha relay katika kesi ya malfunction .

RELAYS Moduli unaweza kuwa madereva nguvu ya hiari ya PWM (Pulse upana Modulated) Dimmers (hadi 3) , zinazotolewa kutoka 12 V DC na 15V ndogo nguvu 50W kwa pato . Inaweza kutumika kwa ufasaha wa dimming mwanga DC (moja kwa moja sasa) . taa tu 30W yanaweza kushikamana na moja dimmer pato . Assuring uingizaji hewa mzuri wa moduli ni lazima . Katika kesi wa uingizaji hewa ya kutosha , shabiki lazima imewekwa kwa nguvu ya hewa mtiririko .

Hii ujenzi wa dimmer inaruhusu kuepuka usumbufu wa flashing na hum ambayo inaonekana katika dimmers triac au thyristor chini 230V/AC .

Madereva ya dimmers inaweza tu kushikamana na taa au LEDs . Maombi mengine inaweza kusababisha madhara ya kudumu ya mfumo ikiwa ni pamoja na moto .

Ni ni hasa kuhusu na mizigo kufata e . g . motors , Mwenye nguvu mashabiki .


3 . 7 . CommManager - Jumuishi mawasiliano moduli , GSM , mfumo wa usalama , roller meneja , eHouse 1 server .


CommManager ni moduli ambayo wanaweza kutenda kama server PC eHouse na mfumo kubwa funktionalitet , bila ya mahudhurio ya kuendelea na PC . CommManager ni binafsi zilizomo mfumo wa usalama pamoja na taarifa GSM (SMS) na kudhibiti . Pia ina kujengwa - katika Meneja Roller . CommManager inaweza kushikamana na eHouse 1 data basi na kazi kama server kwa eHouse 1 vifaa .

Katika CommManager hii kesi nafasi ExternalManager (EM) , InputExtenders (IE) , Expander (EX) na RS232 - RS485 Converter . CommManager ina GSM moduli kwa ajili ya udhibiti wa moja kwa moja kupitia SMS , eMail . Zaidi ya hayo ni Ethernet ina interface kwa ajili ya udhibiti wa moja kwa moja TCP / IP (juu LAN , WiFi au WAN) . Hii inawezesha mbalimbali - Channel huru mawasiliano kwa ajili ya subsystem muhimu ndani ya nyumba - Mfumo wa usalama .

GSM / SMS si yeye binafsi juu ya hujuma e . g . ukataji mistari ya simu ya dialer kwa ufuatiliaji wa makusudi . GSM signal ni vigumu sana kwa fujo basi ufuatiliaji redio - mistari , kazi frekvenser Amateur rahisi kupotosha kwa nguvu kubwa transmitters akageuka juu wakati wa mapumziko katika .


Kuu makala ya CommManager:

1) Eneo la mabadiliko ya taarifa ya kikundi ,

2) Hai sensor kundi notification ,

3) Alarm deactivation taarifa ya kikundi .

1) Alarm Pembe ya kurejea kwenye (A) ,

2) Alarm Mwanga kurejea kwenye (W) ,

3) Ufuatiliaji Output kurejea kwenye (M) ,

4) Uzinduzi tukio kuhusishwa na Alarm Sensor (E) .


Baadhi ya kazi ya mfumo eHouse 1 PC server na maombi msaidizi si mkono na CommManager:


CommManager Maelezo


GSM / GPRS Module .

CommManager (CM) ina kujengwa katika GSM / GPRS moduli kuwezesha wireless kijijini udhibiti wa eHouse 1 au mfumo EthernetHouse kupitia SMS eMail mwisho mapokezi . E - Mail mteja huonyesha kuangalia mzunguko wa ofisi POP3 post wakfu kwa mfumo eHouse kutumia GSM / GPRS piga - na huduma . Kudhibiti mbalimbali ni kivitendo ukomo na inaweza kufanyika kutoka sehemu yoyote ambapo ni ishara ya kutosha GSM ngazi .

Hii ufumbuzi inawezesha udhibiti salama wa mfumo eHouse na kupokea taarifa kutoka mfumo wa usalama . Ari zilizounganishwa na internet , mistari ya simu si required na ni vigumu unaopatikana katika mwezi kujengwa nyumba , hasa mbali na mji .

Usalama ni kubwa sana kutokana na uhusiano wireless na kuna uwezekano hakuna na uharibifu au hujuma kiungo (kama kwa simu , dialers , internet upatikanaji , nk) . Uharibifu wa laini ya mawasiliano inaweza kuwa random (upepo , hali ya hewa , wizi) au kusudi (hujuma ya kudhibiti afya ya mfumo , na taarifa ya mfumo wa usalama na ufuatiliaji , usalama wa shirika , polisi , mwenye nyumba .

Ukarabati ya mistari inaweza kuchukua muda mwingi , ambayo inafanya mfumo wa usalama zaidi mazingira magumu na mashambulizi na afya kutuma meddelanden kwa mtu yeyote kuhusu kuvunja . Ufuatiliaji redio - mistari kazi frekvenser Amateur na wezi maalumu inaweza kuvuruga yao kwa nguvu zaidi transmitters wakati wa mapumziko katika , kupata muda wa nyongeza . GSM ni kiasi vigumu zaidi kwa afya na inawezesha ufungaji mbali na miji , kivitendo wakati wowote (kabla ya kupata anuani ya nyumba , kufanya simu au uhusiano nyingine nyumba mpya kujengwa) . Kutosha tu GSM ngazi signal anahitajika kufunga mifumo hii .

GSM moduli ina antenna ya nje ambayo inaweza kuwa imewekwa katika nafasi ya , ambapo GSM ni ishara ya nguvu (e . g . juu ya paa) . Katika kesi hii GSM moduli unaweza kupunguza maambukizi nguvu wakati kazi ya kawaida kukamilisha uhusiano . Margin ni nguvu ya kutosha kwa ajili kukabiliana na ya uzalishaji mdogo mdogo - mawimbi, hali mbaya ya hewa , mvua , theluji , ukungu , majani ya miti nk . GSM signal ngazi kubadilika katika miaka kutokana na ujenzi wa jengo jipya lililojitokeza , kupanda miti nk . Kwa upande mwingine mkono wa mkubwa ni ishara ya ngazi ya chini ni kuvuruga yanayotokana na GSM moduli na antenna . Ni muhimu hasa kwa kujengwa - katika ADC kubadilisha fedha , kwa sababu katika hali mbaya kipimo inaweza kuwa vilema na dazeni kadhaa asilimia makosa , ambayo inawafanya unusable . Antenna ufungaji nje ya jengo katika mwelekeo na msingi karibu GSM kituo cha kuongeza kiwango mamia signal mara nini kutia kuongezeka kwa nguvu margin kwa maambukizi GSM , mipaka kutotoa moshi nguvu ya GSM maambukizi na snedvridningar (makosa) ya kujengwa - katika kipimo ADC (Na sensorer Analog iko karibu antenna) .


GSM moduli zinahitaji kazi SIM kadi ya ufungaji na kuangalia , kama si umekwisha au kula (katika kesi ya activations Prepaid) . Kama kadi ni itakapotimia au tupu , masuala mbalimbali yanaweza kuonekana:


Kutuma SMS au barua pepe kupitia kupokea moduli GSM / GPRS ni muda mrefu sana (6 - 30 sec) na kuendelea alishindwa retries (unaosababishwa na huduma inaktiv GPRS au ukosefu wa rasilimali katika kadi ya SIM) , huleta juu ya matumizi makubwa ya CPU CommManager , ufanisi wa matone kwa ajili ya kazi nyingine yoyote na itapungua utulivu wa mfumo mzima wa usalama .


GSM Configuration ni kazi kwa " CommManagerCfg.exe " maombi , ambayo inaruhusu Intuitive kuweka kila chaguo na vigezo kwa ajili ya moduli hii . Module GSM chaguzi tatu ya kwanza tabs .

1) Ujumla ,

2) SMS Settings ,

3) eMail Settings .


Ripoti Ngazi lets alichagua ngazi ya kukata magogo kutuma maombi kwa logi grabber (TCPLogger.exe) au RS - 485 . Ni kuwajulisha CommManager ambayo logi info lazima kutuma (info , maonyo , makosa) . Ni muhimu kwa kutambua na kutatua matatizo (e . g . hakuna rasilimali SIM Card , Hakuna Signal GSM , nk na kuchukua hatua kukarabati) . Kwa ajili ya Ripoti ya Level = chochote 1 umepelekwa kwa logi grabber . Hii chaguo lazima tu ya matumizi ya kuchunguza kubwa , haijulikani matatizo juu ya mfumo . chaguo hili umakini CommManager kutumia CPU na kuathiri utulivu na mfumo ufanisi .

Ya idadi kubwa katika Ripoti ya shamba Level , taarifa ya chini itakuwa kutuma (tu na umuhimu wa juu zaidi kuliko ripoti Level) .

Katika kesi sisi don haja ya kuzalisha kumbukumbu 0 wanapaswa kuchaguliwa hapa .


Disable UART Logging . Chaguo hili Disable kupeleka magogo ya RS - 485 UART . Baada ya uchaguzi huu ni akageuka juu tu TCP / IP magogo inaweza kutuma , baada ya uhusiano TCP / IP grabber Ingia maombi (TCPLogger.exe) na CommManager . Hata hivyo katika kesi ya CommManager reset TCPlogger.exe ni disconnected na logi habari na uhusiano wa karibu wa grabber logi CommManager watakuwa wamepoteza .

Kuwezesha UART magogo inatoa nafasi ya kuingia taarifa zote ikiwa ni pamoja na hii sehemu ambayo itakuwa kawaida kupotea kwa TCPLogger .

Hii magogo mode lazima tu ya matumizi ya kutatua tatizo kubwa sana (ambayo kuonekana katika mwanzo wa utekelezaji firmware) na TCP / IP mawasiliano tatizo .

Kuu hasara ya UART magogo ni kuendelea kutuma kwa RS - 485 na kutumia mfumo wa rasilimali , hakuna jambo kama grabber logi ni kushikamana au si (kwa TCP / IP magogo magogo habari waliotumwa tu wakati TCPLogger ni kushikamana na Server) .

Ya Tatizo jingine ni kwamba UART kumbukumbu ni kutuma eHouse 1 Data Bus , kutumia uhusiano huu na kutoa baadhi ya trafiki , kutuma habari yasiokubaliana na eHouse 1 kifaa kutunga na anaweza kuvuruga vifaa kufanya kazi vizuri . Nyingine ya kutumia magogo yote mode eHouse vifaa 1 lazima disconnected , kwa kuondoa RS - 485 kuvuka cable na kuungana via zisizo kuvuka (1 to 1) na RS232 - 485 Converter . RS232 - 485 kubadilisha fedha lazima kushikamana na maombi yoyote terminal kama mfumuko terminal kazi 115,200 , hata kijinsia , 1 kuacha kidogo , hakuna mtiririko kudhibiti . Katika kesi ya uhusiano TCPLogger RS - 485 magogo ni imeshuka na ni kwa madhumuni ya grabber TCP / IP .


Disable GSM Module . Hii chaguo inawezesha kudumu Disable ya utendaji wote wa moduli GSM / GPRS kama si imewekwa .

Hata hivyo muda kwa ajili ya CommManager na vifaa vyote eHouse ni kuchukuliwa kutoka GSM Moduli , hivyo inaweza huru baadhi ya utendaji kama ratiba ya matumizi (kutokana hadi sasa batili na muda katika mfumo) . Kinadharia wakati unaweza kuwa nje iliyowekwa na CommManagerCfg.exe maombi , lakini itakuwa kuwa upya pamoja na Reset ya CommManager kutoka sababu yoyote .



GSM Moduli namba ya simu shamba lazima lina halali simu namba (e . g . +48501987654) , ambayo hutumiwa kwa GSM moduli . Idadi hii ni kutumiwa kwa idhini na cryptography hesabu madhumuni , na kubadilisha idadi hii itakuwa Disable uwezekano wa mamlaka TCP / IP vifaa kwa kila mmoja .


PIN Kificho . uwanja huu lazima lina halali PIN namba (kwa ajili ya kadi ya SIM) . Katika kesi ya kuweka idadi vibaya , CommManager moja kwa moja disables SIM kadi , na retries nyingi kuanzisha uhusiano . Kutokana na ufungaji stationary mfumo ni sana ilipendekeza kwa kuangalia afya siri , ambayo faida kwa kasi wakati wa kurudia kwenye moduli ya GSM na kukata magogo GSM mtandao .


Hashing Idadi . Hii shamba lina ziada habari kwa mahesabu cryptographic na mamlaka anatarajia 18 hex tarakimu (0 , 1 , 2 , 3 , 4 , 5 , 6 , 7 , 8 , 9 , a , b , c , d , e , f) moja kwa moja bila separators . Baada ya mabadiliko haya lazima idadi Configuration kuwa mzigo kwa vifaa kila EthernetHouse na TCP / IP paneler . Matumizi ya GSM namba ya simu , pamoja na hashing idadi kama sehemu ya cryptographic kazi hoja binafsi huonyesha encryption / decryption algorithms kwa ajili ya ufungaji kila eHouse . Zaidi ya hayo unaweza kubadilishwa kama ni muhimu kwa ajili ya vifaa vyote .


Mamlaka GSM Hesabu . Uwanja huu - lina GSM namba ya simu kwa ajili ya mfumo wa usimamizi kwa SMS . Yoyote kutoka kwa nyingine SMS idadi ni moja kwa moja kupuuzwa na ilifutwa .

e . g . : " +48504111111 , +48504222222 " - comma separated .


Eneo Mabadiliko ya - Taarifa Hesabu SMS . Hii shamba - lina GSM simu idadi ya kutuma SMS notification kuhusu kubadilisha usalama wa eneo pamoja na jina la eneo .

e . g . : " +48504111111 , +48504222222 " - comma separated .


Sensorer Activation - Taarifa Hesabu SMS . Hii shamba - lina GSM simu idadi ya kutuma SMS notification kuhusu sensorer kazi usalama kwa jina (ambayo kukiuka alarm , onyo au ufuatiliaji katika eneo sasa) .

e . g . : " +48504111111 , +48504222222 " comma separated .


Deactivation - Taarifa Hesabu SMS . Hii shamba - lina GSM simu idadi ya kutuma SMS notification kuhusu alarm deactivation signaler kwa watumiaji wa mamlaka (na mabadiliko ya usalama wa eneo) .

e . g . : " +48504111111 , +48504222222 " comma separated .


Eneo Mabadiliko ya suffix . Hii shamba - lina suffix aliongeza kwa eneo jina kwa ajili ya kundi eneo mabadiliko ya taarifa .


Alarm Prefix . Uwanja huu - lina kiambishi awali kabla ya kazi aliongeza majina sensor kengele kwa Sensor Activation taarifa ya kikundi .


Deactivation Alarm . Uwanja huu - ina Nakala alimtuma deactivation kundi notification .


Disable Tuma SMS . Uchaguzi huu disables kutuma SMS notification wote kutoka mfumo wa usalama .


Disable Pokea SMS . Uchaguzi huu disables SMS kuangalia na mapokezi kwa mfumo wa kudhibiti eHouse .


POP3 Mteja (eMail mapokezi)

POP3 Mteja kutekelezwa katika CommManager lina ulinzi kadhaa utaratibu wa kuhakikisha kuendelea na imara kazi hata wakati mbalimbali mashambulizi ya mfumo eHouse .

Katika kesi ya kushindwa moja ya ukaguzi ujumbe hatua ni kuchapa mara moja kutoka server POP3 , bila kuangalia zaidi , kushusha na kusoma ujumbe .

Tu barua pepe wakfu kwa kudhibiti eHouse mfumo (tayari moja kwa moja na eHouse sambamba usimamizi wa maombi) unaweza kabisa kupita wote mifumo ya .

Wote mifumo inaruhusu kupambana na ufanisi na spam , mashambulizi , ajali email , nk .

Hii hatua ni kukamatwa kwa kudumisha ufanisi kuendelea kazi , si kuzalisha trafiki unnecessary juu GSM / GPRS , si overload POP3 mteja na CommManager .

Ukaguzi Hatua ni kama ifuatavyo:


Wote vigezo mteja POP3 na chaguzi ni kuweka katika CommManagerCfg.exe maombi katika Email Settings tab .


Kukubaliwa Anwani ya barua pepe * shamba - lina anwani ambayo ujumbe wa kudhibiti itakuwa akifanya . Yoyote ujumbe kutoka anwani nyingine ni moja kwa moja kutoka POP3 kuchapa server .


POP3 Server IP * shamba lina IP anuani ya kompyuta POP3 . anwani DNS si mkono .


POP3 Bandari NR * shamba lina POP3 server bandari .


POP3 Jina la mtumiaji * shamba lina jina la mtumiaji kwa ajili ya kukata magogo na ofisi ya posta (POP3 server) .


POP3 Password * shamba lina password kwa mtumiaji kwa idhini ya server POP3 .


Ujumbe Somo * shamba lina programed somo halali kwa kutuma matukio ya eHouse mfumo kupitia barua pepe . Nyingine somo la ujumbe kusababisha deletion moja kwa moja bila ya zaidi maonyesho .


Internet Uhusiano Init * shamba lina amri kwa initialize internet connection via GSM / GPRS . Kwa zaidi ya amri operators ni kikao kimoja ( , user , password = " internet " ) . Katika kesi ya tatizo na uhusiano user lazima kuwa kutoruhusu operator GSM kwa vigezo hii .


POP3 Server Kutoka String * shamba lina jina la kichwa ambapo kushughulikia Sender ni kuhifadhiwa , katika kesi ya matatizo Matokeo lazima checked moja kwa moja kwenye server POP3 kutumia telnet maombi .


Ujumbe Header * na Ujumbe Footer * mashamba - unahusisha header na footer kwa mfumo eHouse . kinga hii ni kwa ajili Kasseringen moja kwa moja headers na footers zinatokana na ujumbe kwa POP3 na SMTP server na kuondoa ajali au kuharibiwa barua pepe . sehemu tu kati ya eHouse header na footer ni kutibiwa kama eHouse ujumbe . Wengine ni kupuuzwa .


Disable POP3 Server / GPRS * shamba disables uhusiano na GPRS na kuangalia mzunguko kwa barua pepe .


Zifuatazo masuala na matatizo (juu ya mifumo ya GSM si mfumo eHouse moja kwa moja) wanapaswa kuchukuliwa , kabla ya kuwezesha Mteja POP3 juu GPRS:




Usalama Mfumo .

Usalama Kuingizwa katika mfumo CommManager ni ubinafsi zilizomo na inahitaji:


RF udhibiti na muhimu elektroniki kubadilishwa na moja kwa moja , ukomo usimamizi kutoka Simu za mkononi , PDA , wireless TCP / IP paneli kupitia SMS , eMail , LAN , WiFi , Wan . Inaweza kudhibitiwa nje ya ulinzi na kufuatiliwa eneo hilo na taarifa alarm ni mara moja baada ya sensor Activation (wakati hakuna latency hutumika kama katika mifumo ya usalama kudhibitiwa na keyboards ya ndani) .

Juu na maeneo ya 24 inaweza defined . Kila eneo na wajumbe 4 mask kwa kila ngazi ya sensor kushikamana na mfumo wa usalama .

Kwa kila sensor usalama wa pembejeo , chaguzi 4 hufafanuliwa , katika kesi ya Activation alarm sensor (kama chaguo ni kuwezeshwa katika eneo sasa);


* shamba jina " CommManagerCfg.exe " maombi

Alarm , onyo , kufuatilia matokeo ni kuamsha na kuchelewa programed kuweka katika shamba (" Change eneo Kuchelewa " *) Na mabadiliko ya eneo initialize (Kama shughuli sensor mara wanaona kwa eneo jipya) , kutoa nafasi kuondoa sababu ya alarm . Tu " Onyo mapema " pato ni ulioamilishwa mara moja . Matokeo ni kugeuka mbali moja kwa moja baada ya deactivation ya sensorer wote wanaokiuka sasa usalama wa eneo na kuchelewa kuweka katika mashamba: " Alarm Time " * , " Onyo Time " * , " Ufuatiliaji Time " * , " Onyo mapema Time " * . Wote isipokuwa & ldquo signaler ; Onyo mapema Time " * Ni katika dakika , " Onyo mapema Time " ni katika sekunde .

Juu sensorer usalama na 48 wanaweza kuwa kushikamana na CommManager bila ugani moduli au hadi 96 pamoja na moduli ugani . Sensor lazima kuwasiliana na pekee kutoka nje ya mfumo wowote voltage eHouse (relay au kubadili viungio) . Vya lazima kwa kawaida C. (NC) na kufunguliwa kutokana na chombo hicho Activation .

Mmoja alarm kuwasiliana na chombo hicho lazima kuwa kushikamana na sensor mchango wa CommManager mwingine GND .


schematic13


Inaonekana kutoka kwa kuweka vifaa matokeo (Alarm , Ufuatiliaji , Onyo , Mapema Onyo) , CommManager zituma SMS notification na vikundi 3 ilivyoelezwa juu .

Katika kesi ya ukiukaji alarm , onyo au kufuatilia taarifa ni kupeleka kwa kundi defined katika shamba (Sensorer Activations - Taarifa SMS Hesabu *) ikiwa ni pamoja na majina ya kazi sensorer alarm .

Katika kesi ya eneo CommManager mabadiliko meddela kundi defined katika shamba (Kanda ya Mabadiliko ya - Taarifa SMS Hesabu *) kutuma eneo jina .

Katika kesi hii kama alarm , onyo au ufuatiliaji alikuwa hai pia CommManager meddela kundi defined katika shamba (Deactivation - Taarifa SMS Hesabu *) .


Nje Meneja wa vifaa (Rollers , milango , milango , kivuli awnings) .


CommManager imetekeleza roller mtawala ambayo ni toleo la kupanuliwa ExternalManager na kuruhusu kudhibiti 27 (35 **) kujitegemea rollers , milango , milango ya mfumo , bila moduli ugani na 54 na moduli .


** katika kesi ya mlemavu matokeo ya moja kwa moja ADC (ilivyoelezwa katika Analog Digital Converter sura) 35 rollers huru (chaguo lazima unchecked {Matumizi ya moja kwa moja Kudhibiti (kikomo rollers ya 27) - hakuna Matukio ufafanuzi muhimu *} - katika tab " Analog na Digital Converter Mazingira " ya CommManagerCfg.exe maombi) .


Kuna ni njia 2 ya rollers kuendesha: SOMFY mode au moja kwa moja servomotor mode . Tu kuendesha gari kwa kutumia Somfy kawaida ni kuulinda na mamlaka kwa sababu katika mfumo huu rollers ni vifaa katika kudhibiti na ulinzi moduli kwa rollers dhidi ya overload , kuzuia , kuendesha gari kwa wote mwelekeo , assuring sahihi kuchelewa muda kabla ya kubadilisha mwelekeo .


Rollers , milango , milango anatoa matokeo .

Haya matokeo ni jozi ya matokeo kwa ajili ya kuendesha rollers , milango , milango anatoa katika kiwango SOMFY (default kuweka) au anatoa moja kwa moja .

Kila roller channel katika kiwango SOMFY = roller wazi Pulse (1 sec juu ya A pato) , roller karibu (1 sec Pulse juu ya uzalishaji B) , kuacha (1 sec Pulse juu zote mbili A na matokeo B} .

Vinginevyo matokeo inaweza kutumika kwa ajili ya kudhibiti moja kwa moja ya anatoa motor (kuendesha gari A line kwa ajili ya kuhamia katika mwelekeo mmoja , kuendesha line B kwa ajili ya kuhamia katika nyingine mwelekeo) . Anatoa lazima kujenga wenyewe katika ulinzi dhidi ya kurudia kwenye pande zote mbili , block rollers , mwisho switches , kasi ya ulinzi nk . Vinginevyo katika kesi ya malfunction ya relay , Configuration makosa ya moduli , kuzuia gari na baridi au hujuma , inawezekana gari uharibifu . Ina mfumo wa kujenga katika programu ya ulinzi dhidi ya kuhamia kwenye mwelekeo wote , lakini anaweza ' t kuangalia kama gari itafikia mwisho au wasn ' t blocked na ISN ' t kutosha kulinda rollers . mode Hii inaweza tu kutumika katika hatari mwenyewe na iSys kampuni si kuwajibika kwa uharibifu wa anatoa . Tu mfumo Somfy inaweza kutumika kwa usalama kwa sababu ni kuhusisha ulinzi wenyewe ya driver .



schematic14


Rollers mode inaweza kuweka katika " Rollers Settings " tab ya CommManagerCfg.exe maombi .

Mmoja ya nafasi ya bure unaweza kuchagua: Somfy (" Somfy System " *) , Moja kwa moja servomotor gari (" Moja kwa moja Motors " *) , Kawaida Matokeo (" Kawaida Outs " * - moja matokeo sambamba na RoomManager ' s) .

Kuongeza vigezo zifuatazo na chaguzi unaweza kuelezwa kurekebisha rollers vipimo:

Kila Roller ina matukio yafuatayo:


Kufunga Ufunguzi roller na itaendelea mpaka kuacha katika nafasi ya mwisho .

Na kuacha roller katika kuacha nafasi mbalimbali mwongozo lazima ulianzishwa wakati wa harakati .

(" Ziada Rollers " *) Flag inaruhusu kuhesabu mara mbili ya rollers na uhusiano ugani moduli . Katika kesi ya ukosefu ugani moduli chaguo hili lazima walemavu . Vinginevyo CommManager haitafanya kazi vizuri - ulinzi wa ndani itakuwa restart CommManager cyclically .


Kila roller , mlango , lango , awning kivuli inaweza kuwa aitwaye katika CommManagerCfg maombi .

Ya majina ni kuchukuliwa kwa ajili ya kuzalisha matukio eHouse .


Kawaida matokeo mode .


Katika kesi ya ukosefu wa rollers , milango , milango , nk , inawezekana kutumia CommManager ' s matokeo kama pato standard moja sambamba na RoomManager . Hii inawezesha hawawajui matokeo ya ndani ya nchi hii na Usalama Sensorer activations au Analog na Digital ngazi Converter .


Orodha Matukio ya kuhusishwa na matokeo ya kawaida digital:


Kila Pato ina timer binafsi . TIMERS unaweza kuhesabu sekunde au dakika kulingana na chaguo kuweka katika CommManagerCfg.exe maombi (" Dakika Wakati Kati " * - & ldquo katika ; Matokeo ya ziada " * Tab) .


Kila roller , mlango , lango , awning kivuli inaweza kuwa aitwaye katika CommManagerCfg.exe maombi .

Ya majina ni kuchukuliwa kwa ajili ya kuzalisha matukio eHouse .


Usalama Mipango

Usalama mipango ya kuruhusu kambi ya mazingira yote rollers na usalama katika eneo moja tukio .

Juu ya 24 ya mipango Usalama unaweza kuelezwa kwa CommManager

Katika usalama wa mipango ya kila rollers kufuatia matukio ni iwezekanavyo:


Kuongeza eneo pamoja na mazingira rollers zinahitajika inaweza selected .

Kila mpango wa usalama inaweza kuwa aitwaye katika CommManagerCfg.exe maombi .

Ya majina ni kuchukuliwa kwa ajili ya kuzalisha matukio eHouse .

Eneo mabadiliko ni aktiverat latency sawa na rollers maximal kamili harakati muda (" Rollers Movement Time " *) .

Hii latency ni muhimu , kuwahakikishia kwamba wote rollers kufikia mwisho , kabla ya kuanzisha eneo mabadiliko (vinginevyo switches kuthibitisha rollers kufungwa unaweza kutoa larm) .


Na mabadiliko ya Usalama wa Programu ya vipimo:


16 Channel Analog Kwa Digital Converter .

CommManager ni vifaa katika pembejeo 16 ADC na 10B awali (<wadogo ; 0 ; 1,023> ) , na voltage mbalimbali < 0 ; 3 . 3V) .

Yoyote Analog sensor , powered kutoka 3 . 3V yanaweza kushikamana na pembejeo ADC . Ni inaweza kuwa yoyote ya: joto , mwanga ngazi , humidity , shinikizo , gesi , upepo , nk .

Mfumo inaweza kuongezwa kwa sensorer na wadogo linear (y = a * x + b) , ambayo inawezesha kipimo halisi kutoka sensorer Analog e . g . LM335 , LM35 , Voltage , asilimia % , , .

Nyingine sensorer unaweza kuelezwa kuingia maadili equation katika faili sanidi kwa ajili ya aina sensor . sensorer wadogo Nonlinear inaweza kuelezea katika meza ya uongofu (kati ya thamani halisi na thamani ya asilimia) yenye 1,024 pointi e . g . yanayotokana na maombi math .

Analog sensor lazima kuwa ndogo ya sasa ya kazi na kuwa na hutolewa na 3 . 3V ya CommManager . Baadhi sensorer hawahitaji umeme e . g . LM335 , picha diodes , picha transistors , picha resistors , thermistors , kwa sababu ni powered by Ng'oa - Juu resistors (4 . 7k) , na usambazaji wa nishati 3 . 3V .

Na kupata usahihi maximal ya sensorer cable uhusiano:


CommManager ina GSM Module , ambayo pia inaweza umakini kupotosha sahihi kipimo ya sensorer Analog maadili ya kuongeza makosa yao .

Antenna ya CommManager GSM moduli au wote wanapaswa kuwa imewekwa katika eneo ambapo nguvu signal GSM ilikuwa kipimo .

Bora njia ni kuangalia snedvridningar ngazi kabla ya plaster jengo na kazi GSM moduli kutuma SMS na kupokea barua pepe .


schematic7


Kila Configuration channel ya Analog na Digital Converter ni barabara katika CommManagerCfg.exe maombi katika " Analog na Digital Converter Mazingira " * Tabs .

Na mabadiliko ya ADC parameter (" Muundo Enabled " *) Kwenye Ujumla tab * lazima kuwa kuchaguliwa .

Wengi chaguo muhimu ni kuweka kimataifa kwa ajili ya udhibiti wa moja kwa moja pato (" Kutumia Moja kwa moja Kudhibiti (kikomo rollers ya 27) - hakuna ufafanuzi Matukio Muhimu " *) Kupewa kwa kila channel bendera Hii itawezesha byte moja kwa moja kwenye pato wakfu kwa ADC channel na kuacha chini (Min Thamani *) . Pato itakuwa switched off baada overstep (Max Thamani *) . ngazi hii ni mmoja mmoja kwa kila defined Programu ya ADC na kila ADC Channel .

Kugeuka juu ya uchaguzi huu kutenga rollers mwisho 8 mfumo (iliyobaki inapatikana 27) au 16 ya pato katika mode kawaida , ambayo ni wakfu kwa moja kwa moja udhibiti wa pato hili kama matokeo ya ADC . Kuchagua chaguo hili frees kutoka assigning matukio ya ngazi ADC , na ADC matokeo ni kudhibitiwa kifaa ndani (bila tukio utekelezaji wa mtawala wa ndani au nyingine moja) . Katika Rollers mode Output hakuna njia nyingine ya kupata mitaa udhibiti wa ADC matokeo .


Kila ADC channel ina vigezo na chaguzi zifuatazo:

Sensor Jina : Inaweza kuwa mabadiliko katika shamba " Mabadiliko ya ADC Input Jina " * .

Sensor Aina : Standard aina ni LM335 , LM35 , Voltage , % , . , na kuongeza jina jipya na faili ADCSensorTypes.txt . Kuongeza files lazima kuundwa kwa jina moja kama aina jina sensor , basi nafasi na 1 ya 16 na ugani ".txt " . Katika faili hii 1,024 baadae ngazi lazima lipo . Nakala doesn ' t jambo kwa ajili ya CommManager , tu index kuhifadhiwa na kubeba na mtawala .

Ndogo Thamani (" Thamani min " *) - Kuacha chini ya hii thamani (mara moja wakati wa kuvuka) - Tukio kuhifadhiwa katika (Chini Tukio *) shamba itazinduliwa sambamba na pato itakuwa kuweka (Katika moja kwa moja Output mode kwa ADC) .

Maximal Thamani (" Max Thamani " *) - overstep juu thamani hii (mara moja wakati wa kuvuka) - Tukio kuhifadhiwa katika (Zaidi ya Tukio *) shamba itazinduliwa sambamba na pato itafutwa (katika Matokeo ya moja kwa moja mode kwa ADC) .

Tukio Min (Chini Tukio *) - Tukio na kukimbia , kama kuacha chini ya thamani programed chini (mara moja wakati wa kuvuka) kwa ajili ya sasa ADC mpango .

Tukio Max (Zaidi ya Tukio *) - Tukio na kukimbia , kama overstep juu ya thamani programed upeo (mara moja wakati wa kuvuka) kwa ajili ya sasa ADC mpango .


Analog Digital Converter Programs .

ADC lina mpango wa ngazi zote kwa kila channel ADC . Hadi 24 ADC mipango inaweza kuwa aliumba kwa ajili ya CommManager .

Ni inaruhusu mabadiliko ya haraka ya yote ADC ngazi channels , hufafanuliwa kama ADC mpango (e . g . kwa inapokanzwa mtu binafsi ndani ya nyumba) kwa mbio tukio .

Na ADC kurekebisha mpango:


4 . eHouse PC Package (eHouse 1 version)


Kuongeza na mfumo wa umeme modules eHouse ni vifaa katika msaidizi programu ya kufanya kazi chini ya mfumo wa Windows XP na waandamizi .

Hii paket kuendelea kuwahakikishia , mfumo imara wa kazi , ufuatiliaji wa vifaa hali , mawasiliano ya modules , gateways na viungo mawasiliano Ethernet , Bluetooth , internet , SMS . Inaruhusu mapokezi na Decoding kudhibiti signal kupokea kutoka viungo mbalimbali maambukizi . Ina maombi ya Visualization na usimamizi graphic ya mfumo . Inaruhusu rahisi , Intuitive , salama Configuration ya mfumo mzima eHouse kutoka PC .


4 . 1 . eHouse Maombi


eHouse maombi inaruhusu mawasiliano kati ya mitaala na PC , na kamili usimamizi wa vifaa eHouse . Ni wajibu kwa ajili ya kuzalisha kumbukumbu , kifaa kwa sasa , kujenga takwimu kwa visualization , akustisk notification , kifaa Configuration , mbio matukio ya PC . Maombi lazima mbio wakati wote , kuwahakikishia 100% mfumo . Maombi wachunguzi wa hali ya vifaa na katika kesi ya matatizo ya mawasiliano ya kujaribu upya kifaa , na kama si inawezekana itakuwa ishara ya lazima ya watumiaji . Inaonekana vifaa lina mwenyewe Mawasiliano Watch Dog Timer na katika kesi ya matatizo ya mawasiliano kwa kifaa programed wakati unaweza kuwa upya ndani ya nchi .

Kuu makala ya maombi eHouse:


4 . 1 . eHouse maombi ya vitengo .


4 . 1 . RoomManager Configuration .


Hii kitengo inaruhusu Configuring na Programing (kuweka) yoyote vigezo , utendaji na chaguo kwa eHouse controllers mfumo 1 .

Ni ina sehemu zifuatazo:


1 . Jina kifaa .
shamba hili lina Jina kutambua kifaa katika mfumo eHouse na lazima ya kipekee . Jina ni kutumika kwa ajili ya kuzalisha matukio , kumbukumbu , visualization vitu , ziwe fupi na maelezo (e . g . Saluni , George , Jikoni nk) . Majina lazima kuzingatia kutaja kiwango kwa files na Directories katika mfumo madirisha .

2 . Anwani High , Anwani Low .
Mwisho anwani (2 Byte) ni jumla ya juu na ya chini nibble . Anwani High lazima akae sawa kwa vifaa kikundi na mkataba eHouse ni kama ifuatavyo:

Anwani Aina kifaa

(1 , 1) HeatManager ,

(2 , 1) ExternalManager ,

(55 , x) RoomManagers ,

(254 , 254) PC eHouse server au CommManager ,


Anwani lazima kuwa wa kipekee , vifaa hivyo lazima kuungana na mfumo mmoja mmoja , mara moja kubadilisha kuweka kiwanda default (55 , 55) kwa mfululizo anwani katika mfumo) .

3 . RS - Speed 485 .
kasi ya lazima kutumia default thamani 115,200 na lazima kuweka vifaa kila mfumo wa . Kubadilisha kasi kupunguza thamani inaweza kusababisha upungufu mfumo throughput juu RS485 data bus . Configuration kwa ajili ya maombi ni kazi moja kwa moja katika com.cfg faili na kasi hiyo kwa bandari ya haja ya kuwa na kuweka . DO NOT BADILISHA THIS THAMANI .

4 . Moja kwa moja reset .
Hii ni moja kwa moja wakati (katika dakika) ya restart eHouse kifaa katika kesi ya mawasiliano ya kukosekana kwa eHouse maombi au CommManager . Timer ni upya juu ya kupokea ombi kutoka kwa sasa swala eHouse maombi au CommManager . Kama kompyuta PC si required msaada eHouse mfumo wakati wote , thamani hii lazima kuweka 0 Disable moja kwa moja upya au e . g . 60 upya vifaa kwa ajili ya sababu za usalama . Kwa upande mwingine mkono kama hakuna PC wala CommManager ni kutumika eHouse 1 kifaa wakati wa kuanzisha upya huru mazingira yao saa na kipanya matumizi ya maombi ni sahihi .

5 . Kijijini Mdhibiti Aina .
Kwa RoomManager uwanja huu kuruhusu alichagua aina mbali kwa ajili ya kudhibiti RoomManager (tu Sony , N / A ni kukubaliwa) .

Kwa ExternalManager shamba inaeleza idadi ya InputExtenders kushikamana na mtawala .

6 . LVD (Low Voltage kugundua) .
Kama chaguo hili ni kuwezeshwa kifaa zituma alarm ishara ya maombi taarifa nguvu chini ya kuacha kazi salama moduli .

Tu kifaa mmoja lazima kutumia chaguo (ziko mbali zaidi kutoka kwa nguvu usambazaji) . Kupokea signal Alarm husababishwa na usambazaji wa nishati usumbufu au malfunction , na katika kesi ya nguvu ya mara kwa mara larm ugavi lazima iliyopita kwa moja na ufanisi zaidi na mpya .

7 . ExternalManager T wake f bakia lazima kuweka tu kwa ajili ya kushughulikia ExternalManager (ExternalManager lazima 2 , 1) .

9 . Harakati Output 1 , 2 . Matokeo ya kupewa kwa sensorer harakati , e . g . kwa byte kwenye mwanga harakati wanaona katika chumba .

10 . BT Jeshi Jina . Kwa ajili ya Bluetooth rahisi kugundua . Nzima jina ni " eHouse " + < BlueTooth_Device_Name> + ADRL .

11 . BT Password . Kwa idhini na vifaa pairing katika eHouse mfumo .

12 . Kupitia Mawasiliano Module . Katika kesi ya eHouse mfumo 1 uhusiano kupitia CommManager chaguo hii inahitajika kwa ajili ya wote modules . Kifaa kazi katika kushughulikia kupanuliwa mode (kifaa zituma lengo anwani ya kifaa pamoja na kushughulikia mwenyewe) . Kwa kufuata zaidi na eHouse maombi ya ziada parameter / extendedaddress lazima aliongeza kwa amri Mpya .

13 . Hali auto Send . Katika kesi ya matumizi ya toleo TCP / IP na matumizi ndogo kiasi cha eHouse 1 controllers , chaguo hii inaweza kuwa kuchagua , na vifaa atamtuma maswali moja kwa moja katika kesi ya mabadiliko vigezo au baada ya latency programmerad . (Si ilipendekeza)

14 . eHouse 1 Vifaa Count . uwanja huu ni muhimu kwa kuweka maingiliano kati ya eHouse kifaa 1 wakati Auto Status kutuma mode . Lazima kuwa kubwa kuliko hesabu ya vifaa kwenye eHouse 1 data bus (Na sawa kwa wote modules) .


4 . 1 . 2 . Analog Input Settings


Analog pembejeo ni kutumika kwa ajili ya kipimo thamani ya sensorer Analog na awali 10B < 0 ; 1,023> na wadogo < 0 ; 5V) .

Kila pembejeo unaweza kuwa jina lake katika " Analog Input " tab . Madirisha faili na kumtaja directory mkataba sheria lazima iakttagit .

Hii majina kuwa msingi wa matukio na kumbukumbu majina .


Kila pembejeo Analog ina kazi <mbalimbali ; 0 ; 5V) na azimio 10 bits . Ni ina ngazi ya mtu mmoja mmoja kupewa voltage ndogo na maximal (ambayo anatoa 3 safu ya operesheni ADC) . Kuvuka ngazi hii itakuwa kuanzisha tukio moja kwa moja kukimbia , defined na iliyowekwa kwa eHouse.exe maombi . Ngazi hizi ni kwa ajili ya kila mtu binafsi na Channel ADC kila mpango wa RoomManager .

Tatu matukio yanayohusiana na kila ADC kwa kuvuka maadili kipimo:


Kwanza pembejeo ni kwa ajili ya mwanga sensor ngazi (photo transistor) au nyingine na inverted wadogo , pili sensor joto .

Channel 3 - 8 inaweza kutumika na sensor joto au kufanya kazi nyingine katika uendeshaji mbalimbali 0 - 5V .


(*) Kumtaja mkataba kutoka eHouse.exe maombi .


Tukio Majina ni umba wakati Configuration kuokoa (" Kuokoa mazingira na Mwisho " *) Katika hatua ya kwanza ya majina yote iwe umba , na baada ya kuokoa Configuration , Matukio ADC itakuwa inapatikana (kubadilisha kifaa kingine na tena inaweza kuwa muhimu au kutoka maombi katika baadhi ya hali) .



Ndogo na maadili maximal ni kwa ajili ya kila mtu binafsi na mpango RoomManager unatakiwa kuundwa kwa kila profile required kabla ya kunyongwa . Nyingine kesi mbio tukio kusababisha kuweka maadili ya awali umba wakati mfumo initialization .


4 . 1 . 3 . Digital Output Configuration

Digital pato moja kwa moja kwenye gari RELAYS Relay Module , na inaweza kubadili ON (1) au OFF (0) wanaweza kukimbia:


Majina inaweza kuwa mabadiliko ya thamani ya kina kwa ajili ya kizazi zaidi matukio , na wazi kukata magogo katika mfumo wa habari .


4 . 1 . 4 . Infrared Mipangilio (Remote Control) .


Zifuatazo Infrared kudhibiti mazingira zinapatikana:


Kina habari , jinsi configure Infra - nyekundu kwa mfumo eHouse iko katika Description RoomManager .


4 . 1 . 5 . Elektroniki RF Key mazingira (kwa ExternalManager) .

Elektroniki RF muhimu ni ndogo kijijini controllers wakfu kwa usimamizi wa moja kwa moja ya mfumo wa usalama .

Kifungo kazi na eneo ni hapa chini .


___________

/ |

/ B2 B3 |

|

| B1 |

| ON |

|____________ |

|

| \

| \

| \

\ _ /


Kwa Kuzalisha RF signal uppfyller na baadhi ExternalManager mchanganyiko ya kifungo (B1 , B2 , B3) lazima huzuni na baadaye kifungo (Nguvu) lazima taabu kwa ajili ya wachache ya pili . Kubwa ya kifungo bila huzuni yoyote ya B1 , B2 , vifungo B3 kuzalisha code infrared kwa RoomManager badala ya RF signal . Kila matumizi ya kijijini inahitaji wachache mapumziko kwa ajili ya kutekeleza seconds kujengwa - katika capacitors .


Kina habari jinsi configure RF kijijini iko katika ExternalManager maelezo .


4 . 1 . 6 . InputExtender Settings .


Katika nyingine configure InputExtenders kushikamana na ExternalManager kama ugani modules:


4 . 1 . 7 . Kipanya Management .


Matukio kusimamiwa na kuchagua " Tukio Meneja " menu item kutoka eHouse icon katika mfumo tray (prism) .

Na kuongeza tukio " + " button lazima taabu , na baadaye bonyeza mara mbili kushoto ya mouse on line tupu , kuonyesha tukio mhariri .

Na kujenga tukio bidhaa kufuatia hatua haja ya kuwa alifanya .


Baada ya kubadilisha kipanya kwa mtawala eHouse , kifaa wanapaswa kuwa kuchaguliwa katika orodha ya matukio kisha update matukio kwa menu sasa lazima kifaa taabu na shehena ya matukio ya mtawala na kuwezesha kupatikana kwa kufanya .

Badala ya eHouse 1 vifaa (controllers) , kifaa PC hufafanuliwa kwa kunyonga mipango na kazi ya maombi eHouse . Baada ya kuchagua PC kutoka orodha ya waandishi wa habari haki ya kifungo cha mouse kwenye shamba Tukio Jina kuvinjari faili kukimbia kutoka PC eHouse .


Baada ya muundo na upakiaji matukio ya vifaa Tukio Meneja na Tukio Mhariri lazima imefungwa kwa ajili ya kufungwa database sahihi , mfumo ulinzi , kuongezeka kwa ufanisi na viumbe Backup ahueni kwa Mbegu .

Katika kesi ya uharibifu wa data base inaweza kurejeshwa kutoka faili Backup asilia - menu " Matukio kuokoa Database " wa Meneja Matukio .


4 . 1 . 8 . Idhini na kudhibiti upatikanaji .


RoomManager wanaweza kushirikiana na Mifare Kadi Reader . Hii itawezesha kupata ufumbuzi kudhibiti , haki ya vikwazo , udhibiti wa kiwango cha juu . Ni hasa kusaidia katika hoteli , majengo ya umma , ofisi , upatikanaji wa kudhibiti maombi .


Kufunga kadi na msomaji ni watumiaji kwenye PC eHouse Server na tukio programmerad inaweza kuwa ilizindua (e . g . kufungua mlango) .

Kama kadi ya mara ulioamilishwa katika mfumo mask eHouse kupata haki ni mabadiliko kwa sasa RoomManager .

Upatikanaji haki inaweza kuweka kwenye:


Ni inawezekana kuweka matokeo programmerad (kwa ajili ya 10s) kwa ajili ya kufungua electro - sumaku , signal kuzalisha , uthibitisho taa .

Upatikanaji haki pamoja na matokeo ya wakfu ni mmoja mmoja programmerad kwa kila Kadi Mifare . Jina kwa kila kadi inaweza pia defined .

Upatikanaji haki tu zinazotumika kwa ajili ya udhibiti wa ndani ya RoomManager (kudhibiti via PC , Bluetooth vifaa , barua pepe , SMS , TCP / IP ni unaffected)


Na kufikia Configuration kwa kadi kupata Mifare kufuatia hatua haja ya zitafanyika kwa RoomManager sasa:



Tu njia ya kurejesha hali ya upatikanaji wa haki kamili ni kurejesha firmware katika baadhi ya matukio mengine ya kesi inaweza walemavu au kupuuzwa na usalama kizuizi .


4 . 1 . 9 . Nyongeza ya utendaji ya eHouse maombi .

Maombi imetekeleza TCP / IP server kwa amri mapokezi via Ethernet , WiFi , Wan , Intaneti kutoka graphic na asilia TCP / IP paneler . TCP / IP Kudhibiti matumizi ya eHouseMobile kuhitaji maombi (kwa ajili ya usimamizi kutoka PDAs , Mitende , Simu za mkononi msingi Windows Simu 6 . 0) . Madirisha maombi ya simu ni muhimu kwa bemyndigande jopo eHouse mfumo . Kuongeza graphical kudhibiti paneler inasaidia visualization ya matukio (hali ya vifaa ni atapewa na TCP kila kushikamana / IP paneler kwa maombi eHouse) .


eHouse maombi ina TIMERS kutekelezwa kwa kukimbia na kufuatilia mipango kwa hatua ya mzunguko wa e . g . SMS mapokezi , email mapokezi nk .

Configuration kwa ajili ya programu ni kuhifadhiwa katika directory " exec \ " na wajumbe vigezo kwa ajili ya kuendesha na kuangalia maombi . Katika kesi ya hutegemea juu mpango , eHouse maombi unaweza karibu ni .

Kama default kufuatia maombi ni kunyongwa:

Mwenyewe maombi inaweza kuwa aliongeza kudumisha na msaada eHouse mfumo .


Muundo ya Configuration files , kunaweza kusababisha kazi msimamo wa eHouse wote mfumo au malfunction . Kabla ya kufanya mabadiliko yoyote , Backup kamili ni required .


eHouse maombi directory yaliyomo:

4 . 2 . Bluetooth Gateway (BlueGate.exe)

Bluetooth Gateway kuruhusu mapokezi ya matukio kwa mfumo eHouse kutoka simu simu , PDA au Bluetooth paneler . BlueGate.exe lazima mbio wote wakati wanasubiri kwa ujumbe via Bluetooth link . Vifaa lazima paired , na authorization kuwezeshwa na kujitambulisha , ambayo ni muhimu kuweka mfumo salama .

Amri kupokea na kutumbuiza kwa BlueGate ni kuweka " barua pepe \ " directory kwa maombi eHouse .

BlueGate Configuration ni kuhifadhiwa katika Bluetooth.cfg .

Kabla toleo hili bandari faili eneo lazima kuangalia kwa mfumuko terminal maombi , wameitwa kwa ajili ya huduma Serial Port ssp (Bluetooth) kwa ajili ya kutuma taarifa kutoka PDA via Bluetooth .

Kama bandari idadi ni mkubwa basi COM9 kiambishi " \ \ . \ " ni required .


vigezo kuhifadhiwa katika Bluetooth.cfg maana:


Mpya parameter

1 Serial bandari ya idadi ya Bluetooth \ \ \ \ . \ COM19

2 Valid bandari kasi e . g . 115200


Maombi huna haja yoyote nyingine na matengenezo Configuration .


4 . 3 . eMail Gateway (EmailGate.exe) .

EmailGate.exe ni cyclically inayoendeshwa na eHouse.exe maombi . Hii inawezesha maombi eMail msaada kwa ajili ya mfumo eHouse .

Ni inawezesha kupokea amri (matukio) kwa ajili ya mfumo eHouse na kutuma kumbukumbu cyclically , ambayo inaweza kupokea kutoka internet . Kumbukumbu ni kupeleka katika muundo kukubaliwa na Java maombi " Mkono Remote Mtawala " kwenye simu ya mkononi au PDA kwa ajili ya usimamizi wa eHouse mfumo . Amri ni kupokea na kuhifadhiwa katika " barua pepe \ " directory kwa ehouse.exe maombi .


Configuration ya eMailGate.exe ni kuhifadhiwa katika faili email.cfg .

Vigezo kuhifadhiwa katika kila mstari na maana:

Mpya parameter

1 Mapokezi anwani

2 Sender anwani

3 Jeshi Jina

4 POP3 Server Anwani ya IP: Port

5 N / A

6 N / A

7 SMTP Server Anwani ya IP: Port

8 SMTP Jina la mtumiaji

9 SMTP Password

10 Ujumbe subject

11 N / A

12 N / A

13 Count ya kunyongwa kabla ya kutuma kumbukumbu kupitia barua pepe

Maombi huna haja yoyote nyingine na matengenezo Configuration .

Katika kesi ya tatizo " kumbukumbu \ email . log " wanapaswa kuwa checked .

4 . SMS Gateway (SmsGate.exe) .

SmsGate.exe ni kukimbia cyclically na eHouse.exe maombi , ambayo kuwawezesha haraka kutuma SMS kutoka mfumo eHouse kwa njia ya simu ya mkononi au masharti ya GSM moduli . SmsGate.exe maombi hutuma na kupokea SMS . Ni kuondoa moja kwa moja baada ya kukamilika au Timeout . Outgoing SMS ni kuchukuliwa kutoka Smsout directory ya maombi eHouse . Mmoja ni kuhifadhiwa SMS katika moja ya faili , (Mstari wa kwanza lina idadi halali SMS , pili SMS ujumbe .

Alipokea SMS kutoka idadi mamlaka (watendaji wa mfumo eHouse) ni kutumbuiza na matukio ya kuhifadhiwa katika " Barua pepe \ " directory eHouse maombi na Archived katika " Smsin \ " . Ruhusa SMS kutoka idadi nyingine ni kuhifadhiwa katika " Smsin \ rangi \ " , kama lipo vinginevyo ni kuchapa . SMS hazitokani unaweza sorted , kama ndogo directory zitapatikana manually , na jina sawa na simu namba ya simu . SmsGate.exe anaandika matokeo kwa logi faili " Kumbukumbu \ SMS . log " .


GSM Moduli au Installation Simu ya Mkono Simu .


Kwa SmsGate.exe , Moduli GSM lazima imewekwa . Inaweza kuwa nje au ndani . Mengine ya zamani Simu ya Mkono inaweza kuwa imewekwa , na cable uhusiano via USB au RS232 . Cable tu uhusiano ni kukubalika kutokana na umuhimu wa taarifa mfumo wa usalama (Bluetooth au IrDA inaweza tone connections) . Simu shouldn ' t kazi katika mfumo wa uendeshaji (Windows Simu , Symbian , nk . ) Na shouldn ' T kuwa Palm , PDA , Smart simu . Katika kesi hii , kupokea SMS matatizo inaweza kutunzwa , kwa sababu SMSs inaweza kuwa moja kwa moja alitekwa na mfumo wa uendeshaji na ujumbe wa maombi . PC lazima powered by UPS kuwahakikishia kuendelea kufanya kazi eHouse mfumo , SMS mapokezi na usalama meddelanden .

Serial bandari idadi lazima checked kutumia terminal mfumuko . Kama bandari ni idadi mkubwa basi COM9 kiambishi " \ \ . \ " inahitajika . Simu wanapaswa kuwa kushikamana kudumu na usambazaji wa nishati , kwa ajili ya malipo (5V chaja inaweza kubadilishwa na uhusiano na voltage ndani PC ambayo ni bora zaidi ufumbuzi .

Katika kesi ya matatizo ya maambukizi na kasi GSM RS232 lazima kuweka thamani ya chini .

Nyingine chaguzi inaweza kuweka katika faili SMS.cfg (experimentally) ili kupata muda mfupi wakati wa ugonjwa na imara , kazi dosari .


SMS Gateway Configuration .



Mbili kurasa za kutumika kwa Configuration wa moduli: SMS.cfg i SMS . mwili .


Maelezo ya mistari inayofuata ya SMS.cfg :


Mpya NR Default Thamani Range parameter

1 COM1 - 9 Com Bandari Idadi ya NR zaidi basi 9 kiambishi awali " \ \ . \ " ni aliomba .

2 9600 0 - Speed 115,200 (Baud Rate) .

3 TEXT Mode: PDU au TEXT (inategemea modes mkono wa kwa
GSM moduli au simu) .

4 NODEBUG Logging: Debug au NODEBUG (Debug mode inapaswa kutumiwa
tu kwa Configuration GSM AT amri ya ukaguzi na
vigezo) .

5 5 0 - 100 Ndogo Signal Level (kama kushuka chini notification thamani hii
ni kupeleka kwa SMS) .

6 100 0 - 200 Ndogo Betri Level (kama kushuka chini notification thamani hii
ni kutuma kwa SMS) .

7 50 1 - 60,000 mzunguko muda kwa ajili ya kukabiliana na kuangalia juu ya ombi , alimtuma GSM [ms] .

8 50 1 - 60,000 Time ya kupeleka ombi (amri) ya GSM [ms] .

9 30000 0 - 300,000 Time nje kwa ajili ya kukamilisha maombi ya kukimbia - kama overstep , itakuwa terminated mara moja [ms] . Timer ni reset katika maombi kuanza ,

kutuma na kupokea ujumbe .

10 60 0 - 1,000 Count wa mpango wa utekelezaji kwa ajili ya kutuma taarifa ijayo
ya signal au betri za .

Counter ni reset wakati simu ni kushtakiwa na signal ngazi thamani
ni juu ya kiwango cha chini na ujumbe au taarifa alitumwa .

11 Kutoka line hii mamlaka idadi GSM waliotajwa (SmsGate
anapokea ujumbe {amri} kutoka idadi hii) .


Maelezo wa SMS . mwili faili (AT amri orodha ya moduli GSM au SMS) .


Ombi kutuma kwa GSM lazima kuanza na kiambishi Char " > "

Mwitikio kupokea kutoka GSM lazima kuanza na kiambishi Char " < " Na daima kuwa ipo baada ya ombi kutuma (kuhesabu ombi na majibu lazima kuwa sawa)

" % " ; < " Matokeo maana ni kuweka simu . logi faili

mistari bila prefixes " > " , ; < " ni kupuuzwa .

GSM Amri kuhifadhiwa katika SMS . mwili . Ni lazima checked katika mfumuko terminal maombi , kwa sababu amri huweza kutofautiana kwa GSM tofauti simu na modules .


Mfano:

Kutuma AT amri ya (tayari) na GSM moduli na kurudia mpaka kupokea OK

> AT

Ombi amri

< OK

Anatarajia OK Response

> AT + Cops?

Swala Operator jina

< % OK

mpaka majibu OK kupokea na kuweka alama ya jina kwa simu . logi




Kamili mfano kwa GSM katika PDU Mode

Kuangalia GSM kama Tayari

> AT

< OK

Reset GSM kwa kiwanda defaults na kusubiri kwa OK

> AT & F

< OK

Echo Mbali (Nokia , Siemens) wala kubadili jibu (kama haijulikani amri kupuuza)

> ATE

<

> ATE

<

Echo off (Ericsson) wala kubadili jibu (kama amri haijulikani kupuuza)

> ATE = 0

<

> ATE = 0

<

Kuweka Asynchronous maambukizi RLP kusubiri kwa OK

> AT + CBST = 0 , 0 , 1

< OK

Kuangalia GSM betri ngazi ya chini ya kiwango kama atatuma SMS notification na mamlaka watendaji na kuhifadhi matokeo ya simu . logi faili

> AT + CBC

< % OK

mtengenezaji jina na kuongeza matokeo ya simu . logi faili , kusubiri kwa OK

> AT + CGMI

< % OK

Jina mfano na kuongeza matokeo ya simu . logi faili , kusubiri kwa OK

> AT + CGMM

< % OK

kushikamana mtandao operator kuongeza matokeo ya simu . logi faili , kusubiri OK

> AT + Cops?

< % OK

signal kiwango na kuongeza matokeo ya simu . logi , kusubiri kwa OK ikiwa chini ya ngazi ya kutuma SMS notification na watendaji mamlaka

> AT + CSQ

< % OK

kama tayari kusubiri kwa OK

> AT

< OK

Kuweka PDU mode , kusubiri kwa OK . katika SMS.cfg mode PDU lazima kuwa kuchaguliwa na GSM lazima msaada huu mode

> AT + CMGF = 0

< OK

/ / Mbadala mode PDU ni TEXT

Kuweka TEXT mode , kusubiri kwa OK katika SMS.cfg mode TEXT lazima kuwa kuchaguliwa na GSM lazima msaada huu mode

/ /> AT + CMGF = 1

/ / < OK

Kutuma SMS kutoka " Smsout \ " directory moja kwa moja , kusubiri kwa OK

> AT + CMGS =

< OK

Kuangalia kama tayari , kusubiri kwa OK

> AT

< OK

Kuchagua kumbukumbu " Sim " , za GSM kusubiri kwa OK

> AT + CPMS = " SM "

< OK

Kuangalia kama tayari , kusubiri kwa OK

> AT

< OK

Kusoma wote ujumbe (kwa zaidi ya GSM katika PDU na modes TEXT) kusubiri kwa OK , katika kusoma na kufuta SMS

> AT + CMGL

< % OK

baadhi ya mode GSM katika PDU

/ /> AT + CMGL = 4

/ / < % OK

baadhi ya GSM katika TEXT mode

/ /> AT + CMGL = " Rec ALL "

/ / < % OK

kama tayari , kusubiri kwa OK

> AT

< OK

Kuchagua Kumbukumbu " Simu " katika GSM , kusubiri kwa OK

> AT + CPMS = " MT "

< OK

Kuangalia kama tayari , kusubiri kwa OK

> AT

< OK

Kusoma wote ujumbe (kwa zaidi ya GSM katika PDU na modes TEXT) kusubiri kwa OK , katika kusoma na kufuta SMS

> AT + CMGL

< % OK

baadhi ya mode GSM katika PDU

/ /> AT + CMGL = 4

/ / < % OK

baadhi ya GSM katika TEXT mode

/ /> AT + CMGL = " Rec ALL "

/ / < % OK

kama tayari , kusubiri kwa OK

> AT

< OK

Angalia mpya SMS kutuma kutoka " Smsout \ " na kutuma kama kitu mpya , kusubiri kwa OK

> AT + CMGS =

< OK

Kuangalia kama tayari , kusubiri kwa OK

> AT

< OK


4 . 5 . WDT kwa eHouse (KillEhouse.exe)

Kuangalia Mbwa Timer ni ufuatiliaji maombi ya mfumo eHouse kwa ajili ya kuendesha na kuangalia eHouse.exe ya maombi ya kazi ya kuendelea . Katika kesi ya hutegemea juu , kushindwa , ukosefu wa mawasiliano kati ya controllers na eHouse maombi , KillEhouse.exe kufunga maombi na kuanzisha upya tena .

Configuration kurasa za kuhifadhiwa katika " killexec \ " directory .

WDT kwa eHouse kimeundwa wakati wa ufungaji wa mfumo eHouse na ni unattended kama default settings ni halali .

Kwa eHouse.exe maombi na umri wa miaka default " kumbukumbu \ nje . STP " faili ni checked , ambayo ni alama ya sasa hivi karibuni alipata kutoka ExternalManager , kwa sababu hii ni zaidi muhimu na Mdhibiti muhimu katika mfumo . Katika kesi ya ExternalManager ukosefu , HeatManager jina (e . g . " kumbukumbu \ HeatManagerName.txt " ) Logi faili inapaswa kutumiwa au RoomManager (e . g . " kumbukumbu / Salon.txt " ) . Katika kesi nyingine , WDT itakuwa reset eHouse.exe cyclically , kuangalia kwa logi ya zilizopo zisizo mtawala .

Mfano kwa eHouse.exe na RoomManager ' s tu na mmoja wao ana jina Saluni:


e - Nyumba Meneja

ehouse.exe

/ Ne / NR / nt / nd

100000

120

c: \ e - Comm \ e - Nyumba \ kumbukumbu \ Salon.txt


Baadae vigezo mistari ya * . anaendesha faili:

1 Maombi jina katika madirisha

2 executable faili " bin \ " saraka ya mfumo eHouse

3 executable vigezo

4 maximal muda wa kufanya kazi kwa ajili ya maombi [s]

5 maximal wakati wa inactivity [s]

6 faili jina , kuangalia umri kuanzia uumbaji / muundo .


Files " . anaendesha " kwa ajili ya maombi eHouse kuhifadhiwa katika " exec \ " directory kuwa na muundo sawa .

Nyingine maombi zinaweza kuhifadhiwa kwa WDT kwa kuweka files Configuration directory hii .


4 . 6 . Akustisk meddelanden (Player.exe) .

Maombi moja kwa moja ina audio files kutoka foleni - " Redio ya kucheza \ " directory . kurasa za moja kwa moja baada ya kucheza kufuta . Maombi huna haja yoyote Configuration na matengenezo . Maombi si kuzuia uwezekano wa muziki sambamba kucheza kutoka kutoka Winamp , nyingine vyanzo kutoka kadi PC na audio .


4 . 7 . FTP Gateway (FtpGate.exe) .

FTP gateway inawezesha Receptions amri kutoka FTP server . Kuongeza synchronizes magogo na files akizungumzia kwa mfumo online kuangalia hali , kazi sensorer , vifaa kwa kiwango internet Browser .

Katika kesi ya mabadiliko , kuondoa , kuongeza faili " kumbukumbu \ " directory mitaa ufungaji , files kijijini ni kunakiliwa au kufutwa , kudumisha sasa kwa sasa ya mfumo wa , na logi update . Files na ugani Michezo kubwa kisha 3 ni kupuuzwa .

FTP gateway inawezesha matukio ya maambukizi ya ufungaji wa ndani , kuhifadhiwa kwa Internet browser kudhibiti mbinu kutoka sehemu yoyote . Pia itawezesha moja kwa moja kijijini udhibiti wa mfumo eHouse , kwa kuiga kutoka moja ya matukio hatiani kwa foleni FTP .

Matukio ni kupakuliwa na " barua pepe \ " saraka ya paket eHouse . Files lazima kuzingatia eHouse " * . kukimbia " kiwango faili , ni moja kwa moja yanayotokana na eHouse.exe maombi katika " AllEvents \ " directory na kuwa na kunakiliwa kwa WWW eneo / FTP kijijini .


FtpGate.exe maombi ni kuanza na vigezo zifuatazo:


Maombi ni kukimbia na kuhifadhiwa kwa WDTTimer , na configured katika " ftp . anaendesha " faili .

Mfano ya faili Config:


Ftp Gateway kwa eHouse

ftpgate.exe

/ U: Username / P: UserPassword / W: homepage / D: / DestinationDirectory / Interval: 30

1,000

120

c: \ e - Comm \ e - Nyumba \ ftpgate . STP


Configuration pia inaweza kutumbuiza katika " ConfigAux.exe " maombi .

4 . 8 . Internet browser kudhibiti vipengele .

eHouse inawezesha mfumo wa udhibiti wa moja kwa moja kutoka internet browser na mteja ftp kutumia njia mbalimbali:


Mbalimbali mbinu inaruhusu udhibiti wa mfumo eHouse kutoka internet mbalimbali Browsers , Mifumo ya uendeshaji . Katika kesi ya mapungufu njia moja kwa internet browser au mfumo wa uendeshaji , Njia nyingine inaweza kutumika . Kudhibiti unaweza kufanywa kupitia barua pepe au FTP .


Hata mfumo Windows , yoyote Browser internet ina funktionalitet tofauti na mapungufu .

Tatu Browsers Internet muhimu zaidi walikuwa kupimwa kwenye jukwaa Windows:


Kudhibiti mbinu

IE 6 , 8 +

Opera 10 +

Firefox 3 . 6 +

Moja kwa moja FTP kudhibiti

- (1) / +

- (1) / +

- (1) / +

Nakala kudhibiti HTTP (HTML fomu)

+ / -

+ / -

+ / -

Graphical kudhibiti (background image + HTML ramani)

+ / -

+ / -

+ / -

Graphical kudhibiti na faili la XML (scalable Vector Graphics)

- (2) / -

+ / -

+ / -

Graphical kudhibiti faili (scalable Vector Graphics) + JavaScript (compression)

- (3) / -

+ / -

+ / -


Maana ya: (+ / +) => Mfumo ya Udhibiti (kutuma matukio) / kuangalia kumbukumbu , Nakala ya controllers , mfumo , maombi , kazi sensorer , matokeo , pembejeo , nk .



Kwa kudhibiti halali kutoka browser hatua chache lazima kuwa walifanya:


Moja kwa moja kudhibiti files (kwa FTP) na mbinu asilia (HTTP) - HTML fomu ni moja kwa moja yaliyojitokeza kutoka eHouse maombi ldquo wakati & / Html " parameter ni kutumika katika amri Mpya . Mfumo Configuration , assigning majina na matukio ya kujenga lazima kuwa walifanya majina ya awali na tukio mauzo .


Graphical mbinu ni umba katika Corel Draw maombi kwa jumla msaidizi VBA kwa ajili ya kuchimba picha kwa tofauti format .


Kifaa majina , matukio , Nakala za Umoja eHouse.exe maombi , baada ya Configuration kutumia " / Cdr " amri line parameter . Wote mbinu ni yanayotokana na picha moja katika Corel Draw maombi .

Viumbe ya picha (Maoni) ni ilivyoelezwa katika sura . Wote Internet Browser files (html , svg , xml) ni kuzalisha moja kwa moja na Visual Jumla ya msingi , ili kupata maoni juu ya kufanana , kujitegemea wa mbinu kutumika kwa ajili ya kudhibiti graphical:


Pamoja pamoja na masharti JavaScript , PHP scripts , Java applet , vipengele tayari kwa matumizi , bila mwingiliano mwongozo .

Java haja applet kuwa configured kabla ya kuuawa kwanza na Configuration faili yaliyojitokeza kutoka " ConfigAux.exe " maombi , ambayo pia configure: EmailGate.exe , Visual.exe , Mkono Remote Meneja , eHouseMobile .


Yaliyomo telefonkataloger HTML i XML kutoka eHouse directory mfumo lazima uploaded server WWW / FTP directory huo kijijini , kuanzisha kwa " FtpGate.exe " . " AllEvents \ " directory lazima kunakiliwa na eneo moja , kama moja kwa moja FTP kudhibiti itakuwa kutumika .


Hali kwa ajili ya internet server (anwani huo / mashine) kuwahakikishia kamili utendaji wa kudhibiti eHouse:


(*) script inaweza kubadilishwa kama hii wasn hali ' t alikutana .


Nitafanya kuchaguliwa mbinu katika Internet Browser:


4 . 8 . 1 . Nakala HTML Udhibiti .


4 . 8 . 2 . Graphic Udhibiti HTML + Maps .


4 . 8 . 3 . Graphic kudhibiti XML + faili .


4 . 8 . 4 . Graphic Udhibiti faili + JavaScript (Compression) .


4 . 8 . 5 . Moja kwa moja FTP kudhibiti (Windows Explorer au FTP mteja) .


schematic15



Kuangalia kumbukumbu na mataifa ya vifaa kupitia FTP:


Zifuatazo upatikanaji wa haki kwa files na Directories ni muhimu WWW / FTP , na kufikia funktionalitet kamili .


Directory / Picha

Mmiliki ACL

Kundi ACL

Nyingine

ehouse /

XRW

XR

- - -

ehouse/*.htm *

XRW

XR

- - -

ehouse/*.svg

XRW

XR

- - -

ehouse/*.xml

XRW

XR

- - -

ehouse/*.jar

XRW

XR

- - -

ehouse/*.js

XRW

XR

- - -

ehouse/*.php

XRW

XR

- - -

ehouse/*.*

XRW

R

- - -

ehouse / barua pepe /

XRW

RW

- - -

ehouse/AllEvents/

XRW

R

- - -

ehouse / magogo /

XRW

R

- - -


Ziada scripts na maombi:


4 . 9 . Mkono Remote Meneja kwa eHouse .

Simu Meneja wa kijijini ni Java maombi (MIDP 2 . 0 , CLDC 1 . 1) , kwa ajili ya simu simu na ni lazima kuwa imewekwa juu ya Smart Simu au PDA kwa mitaa (kupitia Bluetooth link) na kijijini (SMS , eMail) udhibiti wa mfumo eHouse . Ni itawezesha kupeleka matukio ya eHouse mfumo na kupokea mfumo wa kumbukumbu kupitia email . Inawezesha kudhibiti kwa kuchagua kifaa na tukio kutoka orodha , kuongeza foleni na hatimaye kutuma eHouse System .



Kuchagua na kuangalia Simu ya Mkono Simu ya eHouse matumizi ya mfumo .

Kwa eHouse za kudhibiti mfumo PDA au Smart ni ilipendekeza pamoja na kujenga katika transceiver Bluetooth , ambayo kuongeza faraja na kuwawezesha bure za kudhibiti badala ya kulipa kwa SMS au barua pepe . Simu za mkononi kazi juu ya mifumo ya uendeshaji kama Symbian , Madirisha Simu , nk , ni vizuri zaidi , kwa sababu ya maombi kufanya kazi wakati wote katika background na inaweza kwa urahisi na kwa haraka accessed , kutokana na multitasking ya mfumo wa uendeshaji .

Hali kwa ajili ya simu za mkononi kwa ajili ya matumizi ya starehe na funktionalitet kamili ya Mkono Remote Meneja maombi:


Kabla kununua simu ya mkononi kwa cheti eHouse mfumo mtihani na mtihani toleo iwe imewekwa juu ya kifaa taka kwa sababu wengi viwanda vya baadhi ya utendaji wa msaada java kufanya matumizi ya Mkono Remote Meneja wasiwasi au hata haiwezekani . Mwingine mambo ni mapungufu operator kama mlemavu ufungaji wa vyeti , mlemavu ufungaji wa maombi mapya , kikomo utendaji wa simu . Hiyo ya simu za mkononi mfano kununuliwa katika duka bila kizuizi operator inaweza kufanya kazi kwa usahihi chini eHouse maombi , na inaweza kufanya kazi katika baadhi ya alama kutokana na kuzuiwa ya operator (e . g . simlock , kusainiwa vyeti , maombi ufungaji) . Mapungufu ya mtindo huo inaweza kuwa tofauti na nyingine operators .


Programu mara kupimwa kwa mfano kwenye Nokia 9,300 PDA .


Hatua kwa ajili ya kuangalia Simu ya Mkono Simu ajili ya matumizi ya eHouse:

1 . Kuweka SIM kadi na kuweka tarehe 1 Februari 2008 (kesi cheti uhalali) .

2 . Kuangalia ya kutuma SMS na barua pepe kutoka kwa simu ya mkononi .

3 . Kufunga mtihani cheti cha moduli .


Cheti wanapaswa kuwa nakala ya simu ya mkononi na kisha kuongeza katika Cheti Meneja kusainiwa kwa Java maombi . Katika kupata haki kwa ajili ya cheti hatua zifuatazo waruhusiwe (maombi ufungaji , Java ufungaji , salama mtandao) . Kuangalia cheti online lazima walemavu .

Kama cheti unaweza ' T kuwa imewekwa mfano mwingine wa simu lazima kutumika .


4 . Kufunga mtihani maombi juu ya simu ya mkononi .


Nakala ufungaji files *.jar na * . jad ya simu ya mkononi na suffix " bt - saini " - kwa mfano kwa Bluetooth na imewekwa cheti au " saini " - bila Bluetooth na kwa cheti imewekwa Install aliomba maombi . Baada ya Maombi ya ufungaji kuingia na kuweka mazingira Meneja wa usalama kwa ajili ya maombi ya juu zaidi ya kuondokana na swali kuendelea mfumo wa uendeshaji . Majina mazingira na haki za unaweza kuwa tofauti kutegemea juu ya simu mfano wa kuigwa na mfumo wa uendeshaji .

Zifuatazo kupata haki kutumiwa na Mkono Remote Meneja:


5 . Maombi Configuration .

Katika isys directory hutolewa kwa mtihani mabadiliko ya ufungaji marudio namba ya simu kwa SMS kupeleka SMS.cfg faili (kuondoka tupu ya mstari wa mwisho wa faili) .

Katika " Bluetooth.cfg " mabadiliko ya faili kifaa anwani ya mapokezi Bluetooth amri (kama kifaa inapaswa kupeleka amri kwa Bluetooth) . BT Kifaa kwa anwani hii ni lazima kushikamana na PC na imewekwa na configured BlueGate.exe maombi . simu ya Mkono lazima paired na marudio Bluetooth kifaa .

Nakala " isys " directory yaliyomo , na moja ya maeneo yafuatayo: " D:/isys/" , " C:/isys/" , " isys / " , " Galeria/isys/" , " Nyumba ya sanaa/isys/" , " predefgallery/isys/" , " Moje Pliki/isys/" , " Yangu files/isys/" .




6 . Mtihani wa maombi ya kazi .

Kukimbia TestEhouse Maombi .


- Kusadikisha mapokezi email . Configuration ya internet connection lazima configured katika simu .

Katika menu kuchagua chaguo " Kupokea Files kupitia barua pepe " . 3 pluses inapaswa kuonekana kwenye kioo na baada ya dakika 3 au 4 " Mtazamo Ingia " lazima kuchagua kutoka orodha na kuangalia mashindano ya logi .

Ni lazima inaonekana kama:

+ OK Hello kuna

USER . . . .

+ OK Password required .

PASS ******

+ OK watumiaji katika

Stat

+ OK . .

Kujiondoa

Hii maana ya mapokezi ya barua pepe mara kwa mafanikio ya kumaliza na logi inaweza kuwa C. (" Ingia karibu " ) . Vinginevyo lazima internet connection kuhakikiwa , Inaweza kuwa sababu ya mazingira Activation GPRS .


- Kusadikisha kutuma barua pepe .

. . . . . . . . . . .

> EHLO kuna

< 250 - ********************* Hello Kuna [12 . 34 . 56 . 78]

.

.

.

.

Auth Plain **************************************

< 235 Uthibitishaji ilifanikiwa

> Barua pepe FROM: 123 @ 123 . pl

< 250 OK

> RCPT TO: 1312312 @ 123 . pl

< 250 Kukubaliwa

> DATA

< 354 mwisho data na < CR> < LF> . < CR> < LF>

> Kutuma headers na mwili ujumbe

< 250 OK id =*****************

> Kujiondoa

< 221 ************** Kufunga uhusiano


Katika kesi ya matatizo signal simu lazima kuhakikiwa . Kadhaa majaribio inapaswa kutekelezwa .


- Ukaguzi wa SMS kutuma:


- Ukaguzi ya kupeleka tukio via Bluetooth:

Bluetooth Ingia lazima inaonekana kama yafuatayo:

Uchunguzi katika Maendeleo (a)

Kifaa Kupatikana: *********************

Mwenyeji ********** (****************) Katika Range

Kutafuta Huduma kwa eHouse

eHouse Huduma Found

Kushikamana Huduma ya eHouse

Kusoma Majibu kutoka Server (b)

Data walifanya mafanikio na Server


Kama sehemu tu ya logi visas kwa uhakika (a) , hii ina maana ya kifaa orodha katika Bluetooth.cfg faili wasn ' t ilianzishwa , ni akageuka mbali au si katika mbalimbali .

Kama sehemu ya logi visas mwisho kabla myeyuko (b) , ina maana hii si mamlaka au configured vizuri . Vifaa lazima paired kudumu , hivyo uhusiano wowote inaweza kuwa imara , bila maswali kwa ajili ya uthibitisho .

Kama kumbukumbu alikuwa visas hadi hatua (b) , hii ina maana BlueGate si mbio au ni kushikamana na bandari vibaya .


Java programu ufungaji PDA .

Kadhaa hatua haja ya kuwa walifanya manually na maombi ya kufunga .

Cheti wanapaswa kuwa nakala ya simu ya mkononi na kisha kuongeza katika Cheti Meneja kusainiwa kwa Java maombi . Katika kupata haki kwa ajili ya cheti hatua zifuatazo waruhusiwe (maombi ufungaji , Java ufungaji , salama mtandao) , cheti kuangalia online lazima walemavu .

Kama cheti unaweza ' T kuwa imewekwa mfano mwingine wa simu lazima kutumika .


4 . Kufunga maombi juu ya simu ya mkononi .


Nakala ufungaji files *.jar na * . jad ya simu ya mkononi na suffix " bt - saini " - kwa mfano kwa Bluetooth na imewekwa cheti au " saini " - bila Bluetooth na kwa cheti imewekwa Install aliomba maombi . Baada ya Maombi ya ufungaji kuingia na kuweka mazingira Meneja wa usalama kwa ajili ya maombi ya juu zaidi ya kuondokana na swali kuendelea mfumo wa uendeshaji . Majina mazingira na haki za unaweza kuwa tofauti kutegemea juu ya simu mfano wa kuigwa na mfumo wa uendeshaji .

Zifuatazo kupata haki kutumiwa na Mkono Remote Meneja:


Kama cheti unaweza ' T kuwa imewekwa , ufungaji toleo na suffix " notsigned " wanapaswa kuwa walifanya . Hata hivyo hii ya maombi ni unrecommended sababu System kuomba user mara nyingi kwa kukubalika kabla ya kukamilika kwa shughuli yoyote ilivyoelezwa hapo juu .


5 . Maombi Configuration .



Bluetooth Configuration .

BT kiungo Configuration " Bluetooth.cfg " faili ina anwani wa vifaa kuhusishwa Bluetooth kusaidia mfumo eHouse kila anwani kwenye mstari mmoja (anwani hadi 10 ni kukubaliwa) . Maombi kabla Kesi ya maambukizi Bluetooth , kukimbia ugunduzi kazi , na kisha zituma matukio na kifaa kwanza kupatikana kutoka katika orodha . Bluetooth vifaa vingine basi sambamba na eHouse mfumo cant kuwa kuongeza faili Configuration sababu Bluetooth maambukizi inahitaji uthibitisho kutoka mwenyeji . simu ya Mkono lazima paired pamoja na vifaa vyote kutoka katika orodha katika " Bluetooth.cfg " faili (kwa uhusiano wa moja kwa moja bila maswali yoyote (uwazi mode) . huo ni required kutoka upande wa Bluetooth vifaa , ambazo lazima paired ya simu ya mkononi kwa moja kwa moja uhusiano .

Kwa kila Bluetooth Vifaa passkey huo unapaswa kupewa , na chaguo authenticate + Encrypt inapaswa kutumiwa .

Kutokana mbalimbali mdogo wa Bluetooth (hasa kwa simu za mkononi na BT Daraja la pili - mbalimbali maximal ni kuhusu mita 10 juu ya hewa ya bure) . Katika maeneo ambapo katika line moja kwa moja kati ya simu za mkononi na Bluetooth kifaa nene ukuta lipo , chimney , sakafu kuvunja uhusiano yaweza kuonekana kutokana na usumbufu kutoka kwa mifumo mingine WiFi , GSM , nk . Hesabu ya Bluetooth moduli lazima iliongezeka na kufikia inatarajiwa mbalimbali ya udhibiti katika nyumba na nje ya . Mmoja kifaa BT inaweza kuwa imewekwa kwenye PC (eHouse server) , wengine yanaweza kushikamana na RoomManager ' s ugani yanayopangwa . Data kuhamisha via Bluetooth ni huru na wa ndani tu .

Bluetooth maanani .

Bluetooth lazima manually kurejea katika ya Mkono Simu kabla initialize uhusiano . maombi mengine itatumika Bluetooth shouldn ' t configured kwa uhusiano wa moja kwa moja na simu ya mkononi , ambayo mara nyingi kutenga wote njia Bluetooth inapatikana kwenye simu (e . g . Nokia PC Suite , Piga Up juu Bluetooth link , Meneja faili kama BlueSoleil) .


Mfano ya Bluetooth.cfg faili

01078083035F

010780836B15

0011171E1167



SMS Configuration .

Mmoja faili " SMS.cfg " haja ya kuwa na kuweka kwa SMS Configuration . Faili hii lazima ina halali Mkono Simu namba kwa ajili ya mapokezi SMS kupitia mfumo eHouse .

SMSGate PC lazima imewekwa na configured vizuri , na cyclically kukimbia . ufumbuzi nyingine ni mapokezi kwa CommManager , ambayo inashirikisha GSM Moduli .


Mfano wa SMS.cfg faili

+48511129184



eMail Configuration .

ya POP3 eMail na wateja SMTP ni kuhifadhiwa katika " email.cfg " faili .

kila Mpya baadae unahusisha kuweka zifuatazo:

Mpya NR parameter mfano thamani

1 SMTP anuani ya barua pepe (sender) tremotemanager@isys.pl

2 POP3 anuani ya barua pepe (receiver) tehouse@isys.pl

3 jeshi jina kwa ajili ya SMTP kuna

4 IP anuani ya kompyuta POP3 (kasi kisha DNS): portnr mail.isys.pl: 110

5 POP3 Jina la mtumiaji tremotemanager+isys.pl

6 password 123,456 kwa ajili ya POP3 mtumiaji

7 IP anwani ya SMTP server (kasi zaidi kuliko DNS): portnr mail.isys.pl: 26

8 mtumiaji jina kwa ajili ya SMTP server tremotemanager+isys.pl

9 mtumiaji nywila kwa SMTP server 123,456

10 Ujumbe somo eHouse Udhibiti

11 Idhini ya y SMTP , Y , 1 (kama ndiyo) ; n , N , 0 (kama hakuna)

12 tupu Mpya


Hii Configuration inawezesha amri kutuma kwa mfumo eHouse , kupitia barua pepe . huduma ya GPRS lazima kuwezeshwa kwa GSM operator na internet connection lazima configured kwa uhusiano moja kwa moja . Kuongeza EmailGate lazima configured na kukimbia cyclically kwa ajili ya kuangalia eHouse ari ofisi ya posta na kutuma kumbukumbu .

Kutuma na kupokea barua pepe ni kulipwa na gharama wanategemea kutoka operator .


Simu Meneja kijijini Usage .

Maombi ina rahisi na Intuitive user interface , kuhakikisha ufanisi na vizuri kazi kama za wengi kama iwezekanavyo . Kutokana na tofauti kuonyesha ukubwa na uwiano , majina na chaguzi ni minimized , kuwa inayoonekana muziki yoyote .

Data kwa ajili ya maombi Java ni RECREATED kila wakati eHouse maombi ni kunyongwa na kubadili / simu na lazima RECREATED baada ya jina mabadiliko , mpya ya mipango ya kuundwa , nk , na kunakiliwa kwa simu ya mkononi (Isys) directory .


Vifaa majina yao kuhifadhiwa katika vifaa.txt file na inaweza kuwa na mtu mmoja mmoja na manually sorted by user . Katika mstari mmoja mmoja jina ni lazima kifaa zilizomo , tarehe ya mwisho ya faili .


Matukio majina ziko katika files kwa jina moja kama kuhifadhiwa katika vifaa.txt file na Chars iliyopita Kipolishi kikanda ASCII kiwango barua (na ugani ".txt " , ili kuepuka matatizo na faili viumbe juu ya mifumo ya uendeshaji wengi kwenye simu ya mkononi . Picha yaliyomo unaweza sorted katika njia taka (1 line ina tukio 1) , mmoja tupu Mpya mwisho wa faili .


Wote Configuration files ni umba PC na eHouse.exe maombi madirisha code default page (madirisha . ) Na shouldn ' t kubadilishwa . e . g . (Matumizi mengine ya mfumo wa uendeshaji) . Katika kesi nyingine Chars kikanda itakuwa badala Chars nyingine " hashes " au maombi kuzalisha makosa makubwa zaidi .

3 Uchaguzi mashamba zinapatikana:

Zifuatazo menu items inapatikana:


Kutuma matukio ya eHouse System .


Kupokea mfumo wa kumbukumbu kupitia barua pepe .

Kama kupeleka magogo kutoka eHouse kupitia barua pepe ni kuwezeshwa , kumbukumbu hii inaweza kuwa alipokea kutoka kwa simu ya mkononi kwa ajili ya kuangalia mataifa ya kifaa , pato na pembejeo aktiverat , analog njia maadili .

Menu Bidhaa lazima nitafanya " Kupokea files kupitia barua pepe " , Simu simu shusha kumbukumbu ya hivi karibuni , kuwabadili na kuhifadhi kama files katika " isys / magogo / " directory .

Kukatisha Sasa Transmission

Kutokana makala simu ya simu ya mkononi na kutokea matatizo mbalimbali , kuvunjwa maambukizi , GSM mfumo kushindwa , nyongeza ya usalama utaratibu imetolewa kwa ajili ya kukatisha maambukizi . Kama maambukizi huchukua muda mrefu sana au visas matatizo inaonyesha , kazi hii inaweza kutumika kwa ajili ya kushuka na kukamilisha uhusiano wowote kwa kunyongwa - " Kufuta Operation " kutoka orodha kuu .

Na kutuma upya matukio baada ya tukio kushindwa mpya lazima kuongeza ili kuiwezesha .

Maombi Ingia

Kila maambukizi ya sasa ni watumiaji na katika kesi ya shaka kama kila kitu huenda OK , logi hii inaweza kuwa checked kwa kuchagua

" Maoni Log " kutoka orodha . Baadaye " Ingia karibu " lazima nitafanya .


4 . 10 . eHouseMobile (Windows Simu 6 . 0 na waandamizi)

eHouseMobile maombi inaruhusu online and now udhibiti wa mfumo eHouse kama graphic kudhibiti jopo na taswira ya hali ya mfumo na mmoja mmoja aliumba maoni vitu na kwa mtumiaji (All majina Umoja eHouse.exe maombi na nje ya Corel Draw maombi kwa mkono Visual Basic utendaji) . Support online ni barabara via WiFi , LAN , Wan (TCP / IP msaada) , offline kupitia SMS au barua pepe .

4 . 11 . Maoni na vitu kuundwa kwa visualization na kudhibiti graphical .


Baada ya Configuration mwisho wa vifaa vyote katika maombi eHouse: kumtaja vifaa , Ishara (Analog sensorer , digital pembejeo , matokeo , mipango , alarm sensorer , na viumbe tukio , eHouse.exe lazima nitafanya na " / Cdr " parameter kwa kuchimba majina yote na matukio kwa Corel Draw Macro , kuagiza kwa faili tupu mtazamo .

Maoni kwa jina sahihi lazima umba (katika kesi ya matumizi visualization au graphical kudhibiti - kwa kuiga tupu faili parter . cdr kwa mwezi mmoja aitwaye kama Jina baadaye View) . Maoni inaweza umba katika Corel Draw maombi (Ver . 12 au zaidi) (inaweza kuwa tathmini au toleo demo) .

Baadaye lazima faili Corel Draw kufunguliwa kwa maombi , na bonyeza mara mbili ya faili kutoka " Picha Explorer " na alichagua jumla zana ( - > Visual msingi - > kucheza alichagua kutoka eHouse orodha na hatimaye Visualization . createform) . X , Y ukubwa katika mita inapaswa kuwa aliingia basi vyombo vya habari Create Document button . mapenzi Hii inajenga Kwanza na maalum kawaida na tabaka kwa kila vifaa na matukio ya kila . Safu moja itakuwa muumba kwa jina {jina kifaa (tukio jina)} . Basi lazima script imefungwa na ukubwa ni sahihi na kitengo ni mita . Maoni toleo inaweza kuwa mafanikio katika njia mbili: mwongozo kuchora moja kwa moja kwenye umba , tupu Canvas au moja kwa moja kupitia kazi msaidizi jumla .


4 . 11 . 1 . Moja kwa moja kuchora kwa msaada wa Jumla Kazi .


Hii mode ni hasa msaada wakati tunahitaji mwelekeo sahihi na maeneo e . g . kuteka mpango wa kujenga . Pia huonyesha utangamano na taswira yoyote inapatikana au kudhibiti graphical mbinu katika mfumo eHouse . Njia hii kweli kuweka kifaa maalum na usahihi vigezo defined kwenye safu kuchaguliwa .

Kwa moja kwa moja kuchora vitu wazi (zana - > Visual Basic - > kucheza kuchagua kutoka eHouse orodha na hatimaye Visualization . NewObject) .


4 . 11 . 2 . Mwongozo kuchora ya vitu .


Vitu ni umba manually Canvas ya maoni , kutumia njia Corel ya kuchora . Kutokana na mfumo wa takwimu konsekvensen haijulikani na vigezo ni kupuuzwa na inajulikana tu takwimu zinaweza kusogea .

Na kufikia imagery nzuri zifuatazo tu kitu inaweza kuteka:

Kuchora Ellipsis kuweka Mstatili anaratibu diagonal (X1 , Y1) (X2 , Y2) . vigezo zilizokubaliwa ni:

Kuchora Mstatili na kuratibu diagonal (X1 , Y1) (X2 , Y2) . Kukubaliwa vigezo ni:

Kuchora mstari kati ya pointi 2 (X1 , Y1) (X2 , Y2) . vigezo zilizokubaliwa ni:

Kuchora Rounded Mstatili (X1 , Y1) (X2 , Y2) . vigezo zilizokubaliwa ni:

Kuweka Studio (X1 , Y1)


Kitu wanapaswa kuwa umba kwenye safu required kupewa kwa hali ya kifaa .

Wote Rangi lazima RGB colours , vinginevyo itakuwa kuongoka kwa RGB kama inawezekana . Conversion kama haiwezekani watakuwa kuweka default Michezo (kujaza nyeusi , Red outline) . Inaweza kuwa kisha kubadilishwa na halali rangi kutoka palette RGB

Kwa matumizi ya internet Browser graphic kudhibiti au visualization , browser salama rangi inapaswa kutumiwa .

Baada ya kuweka vifaa vyote muhimu kwa ajili ya vifaa kila , majimbo na matukio . Baada ya viumbe vyote vitu , visualization nje jumla ina kuwa kunyongwa (zana - > Visual Basic - > kucheza alichagua eHouse kutoka orodha na hatimaye Visualization . NewObject) .


" Kuzalisha Files " wanapaswa kuwa taabu , na maoni ya kuundwa kwa njia nyingine , ambayo itakuwa kujenga files kwa aina mbalimbali visualization (Visual.exe , eHouseMobile , Faili , XML , HTML + ramani) . Hiyo inatoa uwezekano na mabadiliko ya mbinu ya kudhibiti au kutumia njia mbalimbali za kudhibiti .

4 . 12 . Akustisk notification viumbe .


Kama user anataka kutumia signaling akustisk wa matukio ya tukio , meddelanden lazima kuwa kumbukumbu au umba ishara kutoka kusikiliza track . Jina ni sawa kama viumbe tabaka {Jina la kifaa (kufupisha tukio jina)} kwa ugani notification mwisho wa muundo sahihi audio . Wote notification lazima iko katika " audios \ " directory eHouse mfumo . AudioGrabber maombi ni muhimu sana kwa ajili ya kurekodi mawasiliano mwenyewe inawezesha kubadilika kwa muundo mp3 na kuhifadhiwa chini ya taka jina .

Sana msaada ni eHouse.exe maombi kipengele mbio kwa moja " / Adl " parameter ambayo inazalisha faili moja kwa moja kwa ajili ya audiograbber kuagiza majina (eHouse anatumia files kuhifadhiwa katika " Majina bandia \ RoomManager \ " directory) kutoka kwenye orodha na kisha moja kwa moja rekodi ya taarifa zote kutoka kwenye orodha yao na kuhifadhi chini ya jina maalum , inaweza kufanya moja kwa moja bila ya kuwa na mahusiano ila mawasiliano kusoma moja kwa moja . grabber Audio kuchunguza kimya na kubadili taarifa ijayo faili . Baada ya kukamilika kwa rekodi ya ujumbe lazima kuhifadhiwa na " audios \ " directory . ujumbe Mpaka 50 yanaweza umba katika mzunguko mmoja (via nje jina) . Baada ya kukamilika kwa hatua hii " eHouse.exe / adl " maombi lazima rerun mpaka kujenga meddelanden wote audio .







eHouse - Akili nyumba mfumo www.isys.pl

Inteligentny Dom eHouse
Inteligentny Dom, Automatyka Budynku
http://www.isys.pl/